• Title/Summary/Keyword: surface inhomogeneity

Search Result 72, Processing Time 0.019 seconds

A Study on Design and Application of Tissue Compensator for 6MV X-rays (6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구)

  • Chai Kyu Young;Choi Eun Kyung;Chung Woong Ki;kang Wee Saing;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

An Experimental Dosimetry of Irregularly-Shaped-Field Using Therapeutic Planning Computer (치료계획용 콤퓨터를 이용한 부정형 조사면의 선량분포에 관한 실험)

  • Park, Joo-Sun;Lee, Gui-Won;Han, Yong-Moon;Kwon, Hyoung-Cheol;Yoon, Sei-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.2 no.1
    • /
    • pp.87-92
    • /
    • 1987
  • The authors have intended to measure intrinsic dose distribution by Farmer dosimeter in irregularly shaped fields such as L, M, T,-shape model in order to determine dose inhomogeneity in those models. We made 2 off-axis points in each model and measured the depth dose at 1.5,5, and 9cm below surface. The results showed $1-3\%$ dose discrepancy between 2 points. We also measured the depth dose by geometric approximation and computer calculation in those models, and came to the conclusion that computer calculation using Clarkson's principle is simpler and the measurements are to the ideal data obtained by the experiment in those three models of irregularly shaped fields than those of geometric approximation method.

  • PDF

Estimation of Nanomechanical Properties of Nanosurfaces Using Phase Contrast Imaging in Atomic Force Microscopy (원자력현미경의 위상차영상을 이용한 나노표면의 미소기계적 특성 평가)

  • Ahn, Hyo-Sok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.115-121
    • /
    • 2007
  • Phase contrast imaging in atomic force microscopy showed a promise as an effective tool for better understanding of micromechanical properties of surfaces at nano scale. A qualitative estimation model for phase contrast images obtained with a tapping mode AFM was developed. This investigation demonstrated the high efficiency of combined analysis of topography and phase contrast images for characterizing nanosurfaces. Phase contrast images allowed estimation of relative stiffness(elastic modulus) of the sample surface. The phase contrast images revealed a significant inhomogeneity of the nano scale worn surfaces. Phase contrast images are also capable of revealing the formation of tribofilms.

The Effect of Lubrication on The Cold Rolling Texture in Low Carbon Steel Sheet (저탄소강판에서 압연집합조직에 미치는 윤활의 영향)

  • 김종수;조용상;허무영
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.85-88
    • /
    • 1997
  • The effect of lubrication on the evolution of the cold rolling texture in low carbon steels was studied by X-ray texture measurement. The cold rolling texture was inhomogeneous through the thickness of the rolling sheet. The type and sharpness of the texture through the thickness and the degree of inhomogeneity were found to be dependent on the friction acting between rolls and the rolled materials. The degree of the through thickness inhomogeneities was higher in the specimen rolled without lubrication. The friction acting on the roll surface led to the formation of the Goss-Orientation in the rolling texture.

  • PDF

An Experimental Dosimetry of Irregularly Shaped Fields Using Therapeutic Planning Computer (치료계획용 컴퓨터를 이용한 부정형조사면의 선량분포에 관한 실험)

  • Kwon Hyoung Cheol;Oh Yoon Kyeong;Yoon Sei Chul;Bahk Young Whee
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.281-285
    • /
    • 1984
  • The authors have intended to measure intrinsic dose distribution by Farmer dosimeter in irregularly shaped fields such as L.M and T shape models in order to determine dose inhomogeneity in those models. We made 2 off·axis points in each model and measured the depth dose at 1.5, 5 and 9cm below surface. The results showed $l\~3\%$ dose discrepancy between 2 points. We also measured the depth dose by geometric approximation and computer calculation in those models, and came to the conclusion that computer calculation using Clarkson's principle is simpler and the measurements are closer to the ideal data obtained by the experiment in three models of irregularly shaped fields than those of geometric approximation method.

  • PDF

Analysis of heat conduction of cylinder block of turbocharged gasoline engine by boundary element method (경계요소법에 의한 터보과급 가솔린기관 실린더블럭의 열전도 해석)

  • 김은태;최영돈;홍진관
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.41-54
    • /
    • 1989
  • In this study, steady state heat conduction problems of the cylinder block of turbocharged gasoline engine were solved by the boundary element method. Surface of the cylinder block was divided by the triangular cells with constant potential. Temperature distribution, effective heat transfer coefficient of the cylinder block were investigated with variation of equivalence ratio, engine speed and boost pressure. The results show that maximum temperature of cylinder block increase rapidly with increasing engine speed and boost pressure. The monolithic structure of cylinder block results in sever inhomogeneity of inner wall temperature at the high engine speed and boost pressure.

  • PDF

Tension/Heat/Thermal Deformation Analysis of a Cold Coiled Strip in Coiling Process (냉연 판재의 권취공정에 있어서 장력/열/변형 해석)

  • 정영진;이규택;강충길
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.39-43
    • /
    • 2002
  • A new model for heat transfer and thermal deformation analysis according to strip mm in coiling process has been proposed. Finite difference analyses for heat transfer of cold rolled coil have been carried out under various coiling tensions and strip crown using the equivalent thermal conductivity for the radial direction of cold rolled coil which is a function of strip thickness, surface characteristics and compressive pressure. The compressive pressure is calculated from a equation expressed as a function of hoop stress and coil tension considering strip mm obtained by experiment. Finite element method for thermal deformation of cold rolled coil has been performed to investigate the effects of the strip crown, the coil tension and temperature. From these analyses, it is found that the axial inhomogeneity of thermal deformation is increased as the strip crown, compressive pressure, and temperature drop in cold coiled strip increase.

  • PDF

Modeling of Defects Nucleation in the Inhomogeneous Liquid Crystal Director Field

  • Lee Gi-Dong;Kim Jae Chang
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.74-78
    • /
    • 2005
  • With the fast Q-tensor method, which can model the defect dynamics in a liquid crystal director field, the nucleation and dynamical behavior of defects is modeled. In order to model the defect, hormeotropic aligned liquid crystal cell with step inhomogeneous electrode which has a height of $1\;{\mu}m$ is used. From the simulation, we can observe the nucleation and line of the defect from surface inhomogeneity and the experiment is performed for confirmation. The experimental result is compared with numerical modeling in order to verify the simulation of the defect nucleation.

Development and Application of Mueller Matrix Ellipsometry (Mueller Matrix Ellipsometry 제작 및 응용)

  • 방경윤;경재선;오혜근;김옥경;안일신
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.1
    • /
    • pp.31-34
    • /
    • 2004
  • We develop Mueller-matrix spectroscopic ellipsometry based on dual compensator configuration. This technique is very powerful for measuring surface anisotropy in nano-scale, especially when materials show depolarization. Dual-rotating compensator configuration is adopted with the rotational ratio of 5:3 originally developed by Collins et al[1]. The instrument can provide 250-point spectra over the wavelength range from 230 nm to 820 nm in one irradiance waveform with minimum acquisition time of Tc=10 s. In this work, the results obtained in transmission modes are presented for the initial attempt. We present calibration procedures to diagnose the system from the utilized data collected in transmission mode without sample. We expect that the instrument will have important applications in thin films and surfaces that have anisotropy and inhomogeneity.

  • PDF

Muller matrix ellipsometry 제작 및 응용

  • 방경윤;경재선;오혜근;김옥경;안일신
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.12-17
    • /
    • 2003
  • We develop Mueller-matrix spectroscopic ellipsometry based on dual compensator configuration. This technique is very powerful for measuring surface anisotropy in nano-scale, especially when materials show depolarization. Dual-rotating compensator configuration is adopted with the rotational ratio of 5:3 originally developed by Collins et al [1]. The instrument can provide 250-point spectra over the wavelength range from 230 nm to 820 nm in one irradiance waveform with minimum acquisition time of $Tc{\approx}10 s$. In this work, the results obtained in transmission modes are presented for the initial attempt. We present calibration procedures to diagnose the system from the utilize data collected in transmission mode without sample. We expect that the instrument will have important applications in thin films and surfaces that have anisotropy and inhomogeneity.

  • PDF