• Title/Summary/Keyword: surface accumulation

Search Result 589, Processing Time 0.023 seconds

A Study on the Temporal Behavior of the Wall Voltage in a surface-type AC panel

  • Kim, Jung-Hun;Lee, Jun-Hak;Choi, Young-Wook;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.175-176
    • /
    • 2000
  • Electric fields and the wall voltages in a surface-type AC PDP cell were measured using a Laser Induced Fluorescence Spectroscopy. For the condition of He 100Torr, 200V sustain voltage and 50kHz sustain frequency, the wall voltage dropped from about 50V to about -75V within $1{\mu}sec$ after the main discharge. And the wall voltage decreased with the rate of $10.8V/{\mu}sec$ due to the accumulation of the space charges after $1{\mu}sec$. But when the operating pressure was 40Torr, it increased with the rate of $4.5V/{\mu}sec$ because the diffusion effect of the wall charge on MgO surface was more dominant than the accumulation effect of the space charges. During the pulse-off period, the wall voltage decreased slightly due to the diffusion of the wall charge. When the sustain voltage was 250V, the self-erasing discharge occurred, and the absolute value of the wall voltage decreased rapidly just after the pulses were off, which was caused by the accumulation of the charges generated by the self-erasing discharge.

  • PDF

Evaluation of efficiency of manual polishing over autoglazed and overglazed porcelain and its effect on plaque accumulation

  • Haralur, Satheesh B.
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.179-186
    • /
    • 2012
  • PURPOSE. The aim of this study was to evaluate the efficiency of manual polishing over autoglazed and overglazed porcelain and their effect on plaque accumulation. MATERIALS AND METHODS. Thirty-six porcelain discs were fabricated out of which 18 each was subjected for autoglazing and overglazing. Half surface of the discs was left intact; the remaining half was roughened with medium grit diamond bur. Roughened surfaces were repolished by porcelain polishing kits (Shofu, DFS, Eve). All the surfaces were evaluated by the perthometer and SEM. Six discs from each sample were placed in human volunteer's mouth for 72 hours to evaluate the plaque accumulation. Acquired data was subjected to ANOVA comparative evaluation. RESULTS. Roughened surfaces had average roughness value of $2.88{\pm}0.1935{\mu}m$. The repolished surfaces by porcelain correction kits Shofu, DFS and Eve, average roughness value reduced to $0.6250{\pm}0.1036$, $0.9192{\pm}0.0953$, $0.9017{\pm}0.1305$ respectively. Autoglazed and overglazed surfaces showed the mean roughness value (Ra) of $0.4217{\pm}0.0685$, $0.3450{\pm}0.0729$. SEM study showed the improved surfaces when subjected for polishing. Plaque accumulation percentage was the highest on roughened surface ($93.83{\pm}6.2552%$), followed by porcelain discs polished by commercial kits. Autoglazed surfaces found to be the best surfaces with the least plaque accumulation ($0.5237{\pm}0.4209%$). CONCLUSION. All the polishing kits used in the study reduced the average roughness by approximately 77%. Corrected porcelain surfaces should ideally be reglazed, alternatively, polish the surfaces before final cementation.

Adaptive Control of Machined Surface Using Current of the Feed Motor at Rest (정지상태 모터의 전류 신호를 이용한 피삭재의 가공면 적응제어)

  • 정영훈;윤승현;조동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.79-82
    • /
    • 1997
  • The current from the feed motor of a machine tool contains substantial information about the machining state. There have been many researches that investigated the current as a measure for the cutting forces. However it has not been reported that indirect measurement of the cutting forces from the current of the feed motor at rest is possible. The cutting force normal to the machined surface influences the machined surface of the workpiece, which makes it necessary to estimate this force to control the roughness of the machined surface. But the unpredictable behavior of the current prevents applying the current to prediction of the cutting state. In this paper, empirical approach was conducted to resolve the problem. Also parametric adaptive and fuzzy logic control strategies are applied to the force regulation problem. As a result, the current is shown to be related to the accumulation of the infinitesimal rotation of the motor, and besides the unpredictable behavior of the current is shown to be caused by the relationship. Subsequently the relationship between the current and the cutting force is identified, and it is presented that control of machined surface using the current of the feed motor at rest is possible.

  • PDF

Assessing the effect of stylus tip radius on surface roughness measurement by accumulation spectral analysis

  • Kwon Ki-Hwan;Cho Nahm-Gyoo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.9-12
    • /
    • 2006
  • A spectral analysis and numerical simulation are employed to assess the effects of the stylus tip radius on measuring surface profiles. Original profiles with fractal spectral densities are generated and then are numerically traced with circular tipped stylus. Instead of their spectral densities, the accumulative power spectrums of traced profiles are analyzed. It is shown that the minimum wavelength of traced profile relates directly to the radius r of the stylus tip and the root-mean-square (rms) roughness ${\sigma}_o$ of original profile. From this accumulation spectral analysis, a formula is developed to estimate the minimum wavelength of traced profile. By using the concept of the minimum wavelength, an appropriate stylus tip radius can be chosen for the given rms roughness ${\sigma}_o$ of the profile.

Structural Characteristics of Fatty Acid Thin films (지방산계 박막의 구조 특성)

  • Jung, You-Ra;Choi, Yong-Sung;Hwang, Yong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.33-36
    • /
    • 2009
  • In this paper, evaluation of physical properties was made for dielectric relaxation phenomena by the detection of the surface pressures and displacements current on the monolayer films of fatty acid monomolecular Arachidic Acid, Stearic Acid using compressing velocity. LB(Langmuir-Blodgett) thin films were manufacture by detecting deposition for the accumulation and the current was measured after the electric bias was applied across the manufactured MIM device. The physicochemical properties of the fatty acid monomolecular Arachidic Acid, Stearic Acid films surface structure has been studied by AFM. We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is gas state, liquid state, solid state. Formation that prevent when gas phase state and liquid phase state measure but could know organic matter that molecules form equal and stable film when molecules were not distributed evenly, and accumulated in solid state only.

  • PDF

Effects of Natural Convection Instability on Membrane Performance in Dead-end and Cross-flow Ultrafiltration

  • Youm, Kyung-Ho;Anthony G. Fane
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.6-10
    • /
    • 1995
  • An inevitable problem feature of membrane processing is concentration polarization (CF) which is a result of the accumulation of retained solutes at the membrane surface. In ultrafiltration (UF), this accumulation can lead to fouling due to the irreversible deposition of macromolecules both at the membrane surface and in the membrane pores. To reduce or control CP and folding, many possible methods have been considered [1]. One of the most effective approaches is to induce fluid instability near the membrane surface by using pusation flow [2, 3], Taylor [4] and Dean [5, 6] vortex flows. Winzeler and Belfort [6] have comprehensively reviewed several possible attempts to use fluid instabihties for improved membrane performance.

  • PDF

Ecological modeling for estimation of a transport and distribution of COD in Kamak Bay (가막만의 COD 거동 및 분포 특성 평가를 위한 생태계 모델링)

  • Kim Dong-Myung
    • Journal of Environmental Science International
    • /
    • v.14 no.9
    • /
    • pp.835-842
    • /
    • 2005
  • The three-dimensional eco-hydrodynamic model was applied to estimate the physical process in terms of COD (chemical oxygen demand) and net supply(or decomposition) rate of COD in Kamak Bay to find proper management plan for oxygen demanding organic matters. The estimation results of the physical process in terms of COD showed that transportation of COD is dominant in surface level while accumulation of COD is dominant in bottom level. In the case of surface level, the net supply rate of COD was 0 -0.50 mg/m2/day. The net decomposition rate of COD was 0 -0.04 mg/m2/day in middle level(3 -6m) and 0.05 -0.1 5 mg/m2/day in bottom level(6m -bottom). These results indicates that the biological decomposition and physical accumulation of COD are occurred predominantly at the northern part of bottom level. Therefore, it is important to consider both allochthonous and autochthonous oxygen demanding organic matters in the region.

A Study on Effect of Jet Mixed Separator Combination for Pre-treatment of Ultrafiltration Membrane Filtration Process (UF 막 여과 공정의 효과적인 전처리 공정으로 분류교반고액분리조(噴流攪拌固液分離槽) (Jet Mixed Separator: JMS) 도입 효과에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Watanabe, Yoshimasa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.38-46
    • /
    • 2005
  • In this research, we tried to combine the coagulation/sedimentation process as pre-treatment with UF membrane filtration to reduce the membrane fouling and to improve the permeate water quality. We used the Jet Mixed Separator (JMS) as coagulation/sedimentation process. We observed that the HPC and E.Coli can't be removed through the direct UF memebrane filtation of surface water. The removal efficiency of dissolved organic substances, indicated by E260 and DOC, was 40% and 15%, respectively. However, the removal efficiency of it increased two time as a result of combination of JMS process as coagulation/sedimentation pre-treatment. This was resulted from the formation of high molecular humic micro-floc through JMS process. The accumulation amount of irreversible cake layer which was not removed by backwashing was less than direct UF membrane filtration of surface water. Moreover, the loading rate of fouling induced substances, such as humic substances and suspended substances, on membrane surface decreased drastically through JMS process. As a result, the accumulation amount of irreversible cake on membrane surface was decreased.

Measurement of the radon and thoron exhalation rates from the water surface of Yixin lake

  • Jiulin Wu;Shuaibin Liu;Tao Hu;Fen Lin;Ruomei Xie;Shuai Yuan;Haibo Yi;Yixiang Mo;Jiale Sun;Linquan Cheng;Huiying Li;Zhipeng Liu;Zhongkai Fan;Yanliang Tan
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1538-1543
    • /
    • 2024
  • The importance of determining the radon exhalation rate from water surface is emphasized by the increased use of radon and its daughter products as tracers in large-scale circulation studies of the atmosphere. There were many methods to measure radon exhalation from water surface. With the development of radon exhalation rate measurement methods and instruments on the surface of the soil, the rock and building materials, so the radon exhalation rate from water surface can be more accurately measured by applying these improved methods and instruments. In this paper, a cuboid accumulation chamber surrounded by foam boards and a RAD7 were used to measure the radon exhalation rate on the water surface at three different positions by Yixin lake. Each measurement was performed 2 h. The radon exhalation rate from the water surface was about 6 × 10-3 Bq m-2s-1. The thoron exhalation rate from the water surface also can be estimated, it is about 0.16 Bq m-2s-1. These results hint that the radon transmission from the lake bottom soil to water and then into the atmosphere.

Influence of Competing Ions and Metabolic Inhibitors on Heavy Metal Accumulation in the Cell of Heavy Metal-Tolerant Microorganisms (중금속내성균의 중금속 축적에 미치는 경쟁이온 및 대사저해제의 영향)

  • Cho, Ju-Sik;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.142-148
    • /
    • 1997
  • This study was performed to develop the biological treatment technology of wastewater polluted with heavy metals. Heavy metal-tolerant microorganisms, such as Pseudomonas putida, P. aeruginosa, P. chlororaphis and P. stutzeri possessing the ability to accumulate cadmium, lead, zinc and copper, respectively, were isolated from industrial wastewaters and mine wastewaters polluted with various heavy metals. The effect of competing ions and metabolic inhibitors on heavy metal accumulation in the cells was investigated. Heavy metal accumulation into cells was drastically decreased in the presence of competing cation, $Al^{3+}$, and also decreased, at a lesser extent, in the presence of competing anions, $CO_3\;^{2-}$ and $PO_4\;^{2-}$. But heavy metal accumulation was not influenced generally in the presence of the other rations and anions. The accumulation of Cd, Zn or Cu by Cd-, Zn- or Cu-tolerant microorganism was remarkably decreased in the presence of metabolic inhibitors, but the accumulation of Pb by Pb-tolerant microorganism was little affected in the presence of metabolic inhibitors. These results suggested that the accumulation of Cd, Zn or Cu by Cd-, Zn- or Cu-tolerant microorganism was concerned with the biological activity depending on energy, and the accumulation of Pb by Pb-tolerant microorganism depended on not the biological activity but the physical adsorption on the cell surface. Each heavy metal-tolerant microorganism also exhibited some ability to accumulate the other heavy metals in solution containing equal concentrations of cadmium, lead, zinc and copper, when measured at 48 hours after inoculation of the microorganisms, but the accumulation rates were somewhat low as compared to the accumulation rates of heavy metal fitting to each tolerance. These results suggested that the accumulation of each heavy metal by each heavy metal-tolerant microorganism was a selective accumulation process.

  • PDF