• Title/Summary/Keyword: supported

Search Result 10,443, Processing Time 0.036 seconds

AES-CCM Hardware Architecture using a shared SBox for home security

  • Tumurbaatar, Selenge
    • 한국정보컨버전스학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.181-184
    • /
    • 2008
  • This work was supported by the MIC(Ministry of Information and Communication), Korea, under the ITRC(Information Technology Research Center) support program supervised by the IITA(Institute of Information Technology Assessment) and Yonsei University Institute of TMS Information Technology, a Brain Korea 21 program, Korea. CAD Tools were supported by IDEC.

  • PDF

Full mouth rehabilitation of fully edentulous patient with implant-supported fixed prosthesis preceding bone graft: A case report (전악 무치악 환자에서 골이식술을 선행한 임플란트 고정성 보철 수복 증례)

  • An, Ju-Nam;Lee, Jung-Jin;Seo, Jae-Min;Kim, Kyoung-A
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.77-87
    • /
    • 2018
  • Prosthetic treatment using implants in fully edentulous patients includes implant-supported fixed prosthesis, implant hybrid prosthesis, implant retained- or supported-over-denture and implant supported fixed prosthesis has advantages such as psychological stability, pronunciation. If an implant supported fixed prosthesis is planned, the implants should be placed in consideration of pronunciation, esthetics, and oral hygiene. For this, clinical and radiological diagnosis is indispensable. When placing the prosthetic driven implant at the site determined from the diagnosis, a sufficient amount of alveolar bone and soft tissue support are required. If these requirements found to be insufficient, a wide range of bone grafting should be performed in advance. In this case, a fully edentulous patient with severe alveolar bone resorption due to periodontal disease was treated with a full mouth rehabilitation using implant-supported fixed prosthesis preceding maxillary sinus graft and alveolar bone augmentation. We report this patient were satisfied with esthetic and function.

CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES (임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가)

  • Seo Ji-Young;Shim June-Sung;Lee Jae-Hoon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.

Effects of a Palliative Care Program based on Home Care Nursing (가정간호기반 완화케어프로그램의 효과)

  • Hwang, Moon-Sook;Ryu, Ho-Sihn
    • Journal of Korean Academy of Nursing
    • /
    • v.39 no.4
    • /
    • pp.528-538
    • /
    • 2009
  • Purpose: This study was done to develop and test a palliative care program based on home care nursing. Methods: A quasi-experimental design was employed. Changes in the variables were evaluated to test effects of the developed program. Participants were patients with terminal cancer and their families receiving home care nursing from six hospitals (experimental group: 24 and control group: 22). Data collection was conducted from February to October, 2006. Chi-square test, Fisher's exact test, t-test, Mann-Whitney U test and repeated measures ANOVA were used to analyse the data. Results: Hypothesis 1, the experimental group receiving this program will experience less pain (severe, average, weak pain) than the control group, was supported. Hypothesis 2, the experimental group will have less symptom experience than the control group, was supported. Hypothesis 3, the experimental group will have higher QOL than the control group, was supported and the last hypothesis 4, family burden in the experimental group will be less than the control group, was supported. Conclusion: The home care nursing based palliative program developed in this study was found to be an effective program to reduce patient pain and symptom experience, to improve patient QOL and to decrease family burden.

The damping efficiency of vortex-induced vibration by tuned-mass damper of a tower-supported steel stack

  • Homma, Shin;Maeda, Junji;Hanada, Naoya
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.333-347
    • /
    • 2009
  • Many tower-supported steel stacks have been constructed in Japan, primarily for economic reasons. However the dynamic behavior of these stacks under a strong wind is not well known and the wind load design standard for this type of a stack has not yet been formulated. In light of this situation, we carried out wind response observation of an operating tower-supported steel stack with and without a tuned-mass damper. The observation revealed the performance of the tuned-mass damper installed on the stack in order to control the wind-induced vibration. Based on the observed data, we performed a wind tunnel test of a specimen of the stack. In this paper we report the results of the wind tunnel test and some comparisons with the results of observation. Our findings are as follows: 1) the tuned-mass damper installed on the specimen in the wind tunnel test worked as well as the one on the observed stack, 2) the amplitude of the vortex-induced vibration of the specimen corresponded approximately to that of the observed stack, and 3) correlation between Scruton number and reduced amplitude, y/d, (y is amplitude, d is diameter) was confirmed by both the wind tunnel test and the observed results.