• 제목/요약/키워드: supply ventilation air

검색결과 179건 처리시간 0.022초

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

환기에 의한 실내 부유오염입자 제거특성에 관한 실험적 연구 (Experimental Study on Removal Characteristics of Indoor Suspended Particulates by Ventilation.)

  • 강태욱
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.133-139
    • /
    • 2005
  • In this paper, the ventilation performance of suspended particulates in indoor side was investigated by step-down method. Experiments were performed in function of mechanical ventilation types and locations of supply and extract air. The type 2 ventilation system shows the highest removal characteristics rather than other 2 types. It means that the displacement ventilation has also good decay rates of concentration compared to mixing ventilation.

선박 복합 밀폐공간 내 환기효율 분석을 통한 공기환경 개선에 관한 연구 (Study on Improvement of Air Quality through Analysis of Ventilation Efficiency in Complex Enclosures of a Ship)

  • 정재훈;송두삼
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.440-447
    • /
    • 2015
  • In the shipbuilding process, the confined work spaces of the ship are formed continuously; the ventilation method can therefore be limited to dilution ventilation due to the complex structure and limited opening of the confined space. Also, it is difficult to evaluate air-quality using measurement and an adequate ventilation method. CFD simulation methods are typically used in analyzing ventilation efficiency in these cases. In this study, a method is suggested to analyze the air quality of the complex enclosures in shipbuilding using CFD. Especially, among the conventional indices, the ventilation efficiency scales or indices, the supply air contribution (SVE4), and the age of the air (SVE3) (fit for the confined and complex enclosure) were applied.

Measurement of Indoor Air Quality for Ventilation with the Existence of Occupants in Schools

  • Shin Hee-Soo;Lee Jai-Kwon;Ahn Young-Chull;Yeo Chang-Shin;Byun Sang-Hyun;Lee Jae-Keun;Kang Tae-Wook;Lee Kam-Gyu;Park Hyo-Soon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.1001-1005
    • /
    • 2005
  • This paper evaluates the performance of ventilation for the removal of indoor pollutants as a function of ventilation rate and the number of occupants in a test room and school classroom. An experimental apparatus consists of a test room, a tracer gas supply system, a gas detector, and a fan for ventilation air supply with a controller. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 using $CO_{2}$ gas as a tracer gas in the test room of 35 $m^{3}.$ For the ventilation air flow rate of 1.0 ACH, a recommended ventilation flow rate of Korea school standard for acceptable indoor air quality in the case of one person, CO_{2}$ gas concentration decreases up to $55{\%}$ within 50 minutes without occupancy and increases up to $75{\%}$ in the case of one occupant. Also indoor air quality at the school classroom is investigated experimentally.

초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정 (Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building)

  • 김민휘;김진효;권오현;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

전산실의 환기성능 최적화를 위한 연구 (A Study for Optimization the Ventilation Performance of the Computer Room)

  • 권용일
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.57-62
    • /
    • 2015
  • The objective of the present study is to identify the ventilation problems and to suggest the optimal ventilation system to save energy and to improve IAQ in the computer rooms, which annually performs the cooling operation by the server with the highly thermal load. Numerical results on the temperature and local mean age are presented along with some of the discharge velocities. Results show many interesting aspects of airflow patterns affecting the ventilation performances, according to the discharge velocity of the supply diffuser installed in the bottom surfaces between the servers. As the results, 2.5 m/s of the optimal discharge velocity is needed in order to improve the ventilation performance.

실내 기류패턴에 따른 급기효율과 배기효율의 분포 (Distributions of Local Supply and Exhaust Effectiveness according to the Room Airflow Patterns)

  • 한화택;최선호;장경진
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.853-859
    • /
    • 2001
  • A pulsed tracer gas technique is applied to measure distributions of local mean age and residual life time of air in a half-scale experimental chamber. The room airflow patterns are flow-visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is either at bottom-left(Case 1), bottom-right(Case 2), or top-left(Case 3) location. Results show that the distribution of LMA and LMR are different from each other, but both of them are closely related to the airflow pattern in the space. Results on overall room ventilation effectiveness are provided depending upon ventilation airflow rates for three different supply-exhaust configurations.

  • PDF

A Study on Indoor Environment of Interior with Ventilation

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.267-274
    • /
    • 2006
  • There are no solar loads through windows and heat transfer from outer walls of the building to the interior This study analyzes indoor air temperature and air flow distribution for the interior of buildings or vessels occupying space. Numerical method is adopted to visualize the indoor side environmental situation. that is without heat transmission to outside the building in various cooling load conditions; supply ventilation lighting. occupancy and infiltration in conditioned spaces. Reaching time of an air conditioner is predicted theoretically by cooling load variations. Theoretical modelling of the reaching time shows good agreement with experimental results.

공동주택의 환기방식별 다수실 환기 성능에 관한 연구 - 다수실의 환기경로 및 환기효율 - (Study on Ventilation Performance of Multi-room in Apartment - Airflow and Ventilation Effectiveness in Multi-room -)

  • 권경우;조시진;최의성;박준석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.399-404
    • /
    • 2006
  • Heating and cooling load of ventilation is a very important part of building energy saving. Improving ventilation effectiveness can save building energy consume and supply fresh air to indoor efficiently. So this study measured mulity-zone aiflow and ventilation effectiveness according to ventilation types. Result of measurement show that ventilation effectiveness is depends on ventilation system design rather than ventilation types.

  • PDF

환기구 위치별 실내오염물질의 환기효과 변동에 관한 연구 (A Study on the Variation of Ventilation Effect for Indoor Air Pollutants by Ventilation Hole Sites)

  • 이정주;이주상;김신도
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.226-240
    • /
    • 1995
  • This research has a purpose to achieve experimental data used for design of ventilation systems necessary for indoor air quality control and their operation and management. For the study, spatial concentration distribution of indoor air quality according to pollutant site in a simplified model chamber. In low flow ventilation, flow pattern of indoor air was mainly influenced by diffusion and additionally, spatial distribution was formed by convection. Distribution of ventilation efficiency according to each pattern of model chamber was evaluated. It was confirmed that diffusion patterns of a pollutant among sites were formed, centering around main stream areas of supply and exhaust outlets.

  • PDF