• Title/Summary/Keyword: supply rate

Search Result 2,642, Processing Time 0.03 seconds

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.

2-Stage Optimal Design and Analysis for Disassembly System with Environmental and Economic Parts Selection Using the Recyclability Evaluation Method

  • Igarashi, Kento;Yamada, Tetsuo;Inoue, Masato
    • Industrial Engineering and Management Systems
    • /
    • v.13 no.1
    • /
    • pp.52-66
    • /
    • 2014
  • Promotion of a closed-loop supply chain requires disassembly systems that recycle end-of-life (EOL) assembled products. To operate the recycling disassembly system, parts selection is environmentally and economically carried out with non-destructive or destructive disassembly, and the recycling rate of the whole EOL product is determined. As the number of disassembled parts increases, the recycling rate basically increases. However, the labor cost also increases and brings lower profit, which is the difference between the recovered material prices and the disassembly costs. On the other hand, since the precedence relationships among disassembly tasks of the product also change with the parts selections, it is also required to optimize allocation of the tasks in designing a disassembly line. In addition, because information is required for such a design, the recycling rate, profit of each part and disassembly task times take precedence among the disassembly tasks. However, it is difficult to obtain that information in advance before collecting the actual EOL product. This study proposes and analyzes an optimal disassembly system design using integer programming with the environmental and economic parts selection (Igarashi et al., 2013), which harmonizes the recycling rate and profit using recyclability evaluation method (REM) developed by Hitachi, Ltd. The first stage involves optimization of environmental and economic parts selection with integer programming with ${\varepsilon}$ constraint, and the second stage involves optimization of the line balancing with integer programming in terms of minimizing the number of stations. The first and second stages are generally and mathematically formulized, and the relationships between them are analyzed in the cases of cell phones, computers and cleaners.

The Performance Evaluation of Plate Type STR Reactor with Variation of S/C Ratio and Fuel Supply (연료 공급 및 S/C비에 따른 평판형 STR 반응기 성능 평가)

  • Kim, Hun-Ju;Heo, Su-Bin;Park, Jae-Min;Yoon, Bong-Seok;Lee, Do-Hyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.191-198
    • /
    • 2011
  • According to the propagation of fuel cell system, the importance of that system efficiency is being magnified. Thus, the efficiency improvement of reformer which is the important factor of fuel cell system will be required. This study has been experimentally performed to evaluated the performance of plate type STR reactor. At first, we changed fuel flow rate (2, 3 and 4 l/min) in burner, and then we measured a proportion of hydrogen in produced gas through the STR reactor by G.C for evaluating the performance of plate type STR reactor in various fuel supply conditions. And we changed S/C ratio (2 and 4) and measured a proportion of hydrogen in produced gas through the STR reactor. As a results, condition at fuel flow rate 2 and 3 l/min could not be supplied amount of heat for STR sufficiently. Condition at fuel flow rate 4 l/min could supplied a heat excessively. And condition at S/C ratio 2, reaction occurred insufficiency. But condition at S/C ratio 4 was excess. From above, we found the optimum conditions that were fuel rate 3.5 l/min and S/C ratio 3.

An 8b 52 MHz CMOS Subranging A/D Converter Design for ISDN Applications (광대역 종합 통신망 응용을 위한 8b 52 MHz CMOS 서브레인징 A/D 변환기 설계)

  • Hwang, Sung-Wook;Lee, Seung-Hoon
    • Journal of IKEEE
    • /
    • v.2 no.2 s.3
    • /
    • pp.309-315
    • /
    • 1998
  • This paper describes an 8b 52 MHz CMOS subranging analog-to-digital converter (ADC) for Integrated Services Digital Network (ISDN) applications. The proposed ADC based on the improved time-interleaved architecture removes the holding time which is typically observed in the conventional double-channel subranging ADCs to increase throughput rate. Moreover, the ADC employs the interpolation technique in the back-end subranging ADCs far residue signal processing to minimize die area and power consumption. The fabricated and measured prototype ADC in a 0.8 um n-well double-poly double-metal CMOS process typically shows a 52 MHz sampling rate at a 5 V supply voltage with 230 mW, and a 40 MHz sampling rate at a 3 V power supply with 60 mW power consumption.

  • PDF

Numerical Study of Hydrogen/Air Combustion in Combustion Chamber of Ultra Micro Gas Turbine by Change of Flow Rate and Equivalence Ratio (공급 유량 및 당량비 변화에 따른 초소형 가스터빈 연소실 내 수소/공기 연소의 수치해석 연구)

  • Kwon, Kilsung;Hwang, Yu Hyeon;Kang, Ho;Kim, Daejoong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.103-109
    • /
    • 2013
  • In this study, we performed a numerical study of hydrogen/air combustion in the combustion chamber of an ultra micro gas turbine. The supply flow rate and equivalence ratio are used as variables, and the commercial computational fluid dynamic program (STAR-CCM) is used for the numerical study of the combustion. The flow rate significantly affects the flame position, flame temperature, and pressure ratio between the inlet and the outlet. The flame position is close to the outlet in the combustion chamber, and the flame temperature and pressure ratio monotonously increases with the supply flow rate. The change in the equivalence ratio does not affect the flame position. The maximum flame temperature occurs under stoichiometric conditions.

Oral care status and periodontal disease of middle aged diabetic patients (중장년층 당뇨병환자의 구강관리실태와 치주질환)

  • Kim, Myeong-Seon;Kim, Keon-Yeop;Moon, Bo-Ae
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Objectives: The purpose of the study was to identify the oral care status and periodontal disease of middle aged daibetic patients in Korea. Methods: The primitive data were taken from 238 diabetic people in the 5th Korea National Health and Nutrition Examination Survey(KNHANES) in 2010 - 2012. The variables included general profiles(gender, age, occupied area, education, and smoking), oral care status(brushing time, brushing time, use of oral hygienic supplies, availability of oral hygienic supplies, oral examination, and recognition of oral health state), and diabetes management(morbidity period, treatment, education, and glycosylated hemoglobin levels). Results: Most of the subjects took gargling more than twice a day and it accounted for 73.5%. Oral hygienic supply users accounted for 24.8%, and most of them used floss brush. Oral examination was done in 19.3% of the respondents and 55.0% thought that their oral health status were very poor. The prevalence rate of the periodontal diseases was 46.6%. Female tended to have a higher rate of periodontal disease than the male. Oral hygienic supply users had lower rate of periodntal disease than those who did not use. Those who had poor subjective oral health status had higher prevalence rate of periodontal disease than those who did not. Conclusions: Periodontal disease is closely related to good oral care of middle aged diabetic patients. It is necessary to develop the program for the prevention of the periodontal disease for the diabetic patients.

Case Study of a Field Test for a Smoke Control System Using Sandwich Pressurization (샌드위치 가압을 이용하는 연기제어 시스템의 현장실험 사례 연구)

  • Kim, Jung-Yup;Ahn, Chan-Sol
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Amid the growing number of high-rise complex buildings in Korea, efficient smoke prevention technology in a fire is required and as an alternative of a mechanical smoke control system in high-rise buildings, the use of a smoke control system using sandwich pressurization has been on the rise. In such a system, the appropriate pressure difference and the data for designing the air supply and exhaust flow rate are necessary to prevent the spread of smoke and offer a tenable evacuation environment. As part of such effort, this paper presents a field test process and result after testing a building where such a smoke control system using sandwich pressurization has been installed. A ventilation rate of 6 cycles per hour were applied to simulate the air exhaust flow rate on a fire floor and the air supply flow rate on the floors above and below the fire floor. As a result of the system operation, pressure difference of approximately 260 Pa between the 12th floor of a fire and the 13th floor was generated. The over pressure of the experiment has a serious effect on the evacuation or fire compartment so that it is necessary to examine the improvement.

A Study on the Activities and Logistics Performance of SCM in Fashion Industry - Focused on the Supply Chain of Apparel Companies - (패션 산업의 SCM 활동수준과 물류성과에 관한 연구 - 어패럴업체의 공급 사슬을 중심으로-)

  • 홍인숙;김문숙
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.4
    • /
    • pp.547-565
    • /
    • 2004
  • The purpose of this study was to evaluate the level of SCM activities and the logistics performance by SCM of the three company types in fashion industry· fabric suppliers, apparel manufacturers, and retailers. The level of SCM activities was estimated through the examination of seven factors: commitment and leadership of a top management, flexibility of management, understanding of demand characteristics, integrated management organization, information system, cooperative partnership and communication and exchange of opinion. The logistics performance was measured by improvement in customer service(on time delivery ratio of products, returning rate, treat ratio for A/S, order fill rate, substitute providing capability for being out of stock) and delivery cost reduction. Through questionnaire survey, a total of 214 data for 108 companies of three company types were collected: 46 for 40 fabric suppliers, 123 for 64 apparel manufacturers and 45 for 4 retailers. The analysis of SCM activity levels showed that fabric suppliers had higher degrees in the factor of understanding of demand characteristics, and apparel manufacturers had higher degrees in the factor of information systems. For retailers, the factor of communication and exchange of opinion represented higher degrees. The study on relationship between the SCM activity levels and logistics performance showed that the SCM activity factor of understanding of demand characteristics greatly improved a substitute providing capability for being out of stock in fabric suppliers, and information system improved a substitute providing capability for being out of stock, on time delivery ratio of products and order fill rate in apparel manufacturers. In retailers, the SCM activity factor of understanding of demand characteristics decreased returning rate highly and improved on time delivery ratio of products. The study results showed that SCM activities in fashion industry brought more improvement in customer service levels rather than in delivery cost reduction.

  • PDF

Design of a CMOS D/A Converter for advanced wireless transceiver of high speed and high resolution (고속 고해상도의 무선통신 송 $\cdot$ 수신기용 CMOS D/A 변환기 설계)

  • Cho Hyun-Ho;Park Cheong-Yong;Yune Gun-Shik;Ha Sung-Min;Yoon Kwang-Sub
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.549-552
    • /
    • 2004
  • The thesis describes the design of 12bit digital-to-analog converter (DAC) which shows the conversion rate of 500MHz and the power supply of 3.3V with 0.35${\mu}m$ CMOS 1-poly 4-metal process for advanced wireless transceiver of high speed and high resolution. The proposed DAC employes segmented structure which consists of 6bit MSB, 3bit mSB, 3bit LSB for area efficiency Also, using a optimized aspect ratio of process and new triple diagonal symmetric centroid sequence for high yield and high linearity. The proposed 12bit current mode DAC was employs new deglitch circuit for the decrement of the glitch energy. Simulation results show the conversion rate of 500MHz, and the power dissipation of 85mW at single 3.3V supply voltage. Both DNL and INL are found to be smaller than ${\pm}0.65LSB/{\pm}0.8LSB$.

  • PDF

A Study on the Radial Spray Performance of a Plaint-Jet Twin-Fluid Nozzle (액주형 이류체노즐의 반경반향 분무특성에 관한 연구)

  • 최진철;노병준;강신재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.662-669
    • /
    • 1994
  • In the combustion system, the optimum spray conditions reduce the pollutant emission of exhaust gas and enhance the fuel efficiency. The spray characteristics-the drop size, the drop velocity, the number density and the mass flux, become increasingly important in the design of combustor and in testifying numerical simulation of spray flow in the combustor. The purposes of this study are to clarify the spray characteristics of twin-fluid nozzle and to offer the data for combustor design and the numerical simulation of a spray flow. Spatial drop diameter was measured by immersion sampling method. The mean diameter, size distribution and uniformity of drop were analyzed with variations of air/liquid mass flow ratio. The results show that the SMD increases with the liquid supply flow rate and decreases with the air supply velocity. The radial distribution of SMD shows the larger drops can diffuse farther to the boundary of spray. And the drop size range is found to be wider close to the spray boundary where the maximum SMD locates.