• Title/Summary/Keyword: supply network method

Search Result 305, Processing Time 0.028 seconds

The Method of Force of Fire in High-Rise Building by Guide to the Fire Safety Concepts Tree: Focusing on Manually Fire Suppression Strategy (화재안전트리 이론에 따른 초고층건축물의 소방력 공급방안: 수동화재진압 전략을 중심으로)

  • Oh, Seong-Ju;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.79-88
    • /
    • 2020
  • This study analyzes the issue of the supply of force of fire in the high-rise buildings, and proposes an efficient method to do so. The results are as follows. First, in terms of Detect fire, it is necessary to shorten force of fire supply time by diversifying fire alarms such as alarms, vibrations, and voices from outside, clarification of fire occurrence points, and marking of fire. Second, with regard to communication signals, strengthening the installation target of wireless communication auxiliary facilities, supplementing the installation of repeaters, and constructing a multicommunications network were proposed. Third, in terms of Decide action, it is necessary to supply firefighter and firefighting equipment with the method of crossing of a river in adjacent buildings. Fourth, in terms of Respond to site, helicopters and emergency elevators are used to assist in the supply of firefighting equipment using drones. Easy-to-break glass windows and identification marks are required in every floor. Finally, in terms of applying fire suppressants, water can be supplied by means of a helicopter adjacent to the structure.

Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1789-1794
    • /
    • 2014
  • This paper suggests an application method for a superconducting fault current limiter (SFCL) using an evaluation index to estimate the risk regarding the short-circuit capacity of the circuit breaker (CB). Recently, power distribution systems have become more complex to ensure that supply continuously keeps pace with the growth of demand. However, the mesh or loop network power systems suffer from a problem in which the fault current exceeds the short-circuit capacity of the CBs when a fault occurs. Most case studies on the application of the SFCL have focused on its development and performance in limiting fault current. In this study, an analysis of the application method of an SFCL considering the risk of the CB's short-circuit capacitor was carried out in situations when a fault occurs in a loop network power system, where each line connected with the fault point carries a different current that is above or below the short-circuit capacitor of the CB. A loop network power system using PSCAD/EMTDC was modeled to investigate the risk ratio of the CB and the effect of the SFCL on the reduction of fault current through various case studies. Through the risk evaluations of the simulation results, the estimation of the risk ratio is adequate to apply the SFCL and demonstrate the fault current limiting effect.

Application and performance evaluation of mass balance method for real-time pipe burst detection in supply pipeline (도수관로 실시간 관파손감지를 위한 물수지 분석 방법 적용 및 성능평가)

  • Eunher Shin;Gimoon Jeong;Kyoungpil Kim;Taeho Choi;Seon-ha Chae;Yong Woo Cho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.347-361
    • /
    • 2023
  • Water utilities are making various efforts to reduce water losses from water networks, and an essential part of them is to recognize the moment when a pipe burst occurs during operation quickly. Several physics-based methods and data-driven analysis are applied using real-time flow and pressure data measured through a SCADA system or smart meters, and methodologies based on machining learning are currently widely studied. Water utilities should apply various approaches together to increase pipe burst detection. The most intuitive and explainable water balance method and its procedure were presented in this study, and the applicability and detection performance were evaluated by applying this approach to water supply pipelines. Based on these results, water utilities can establish a mass balance-based pipe burst detection system, give a guideline for installing new flow meters, and set the detection parameters with expected performance. The performance of the water balance analysis method is affected by the water network operation conditions, the characteristics of the installed flow meter, and event data, so there is a limit to the general use of the results in all sites. Therefore, water utilities should accumulate experience by applying the water balance method in more fields.

determination of Optimum Pipe diameter Using Multi-Stage Iterative Method in Water Distribution system (다단계 반복기법을 이용한 관로시스템의 최적관경 결정)

  • Han, Geon-Yeon;Park, Jae-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.3
    • /
    • pp.327-335
    • /
    • 1998
  • The distribution network is an essential part of all water supply systems. The cost of this portion of any sizable water supply system may amount to most of the entire cost of the project. This study tried to reduce the cost of the distribution system through optimization in system design. To determine pipe diameter considered in water distribution system design, a iterative procedure linked the flow analysis model and optimization model was used. Linear theory was introduced to analyze flowrate and revised-simplex method based on linear programming is used to optimize pipe diameter. This model was applied to wter distribution system with 22 and 35 pipes, and rapidly determine optimized commercial pipe diameters. Keywords : water distribution system, revised simplex method, optimum pipe diameters.

  • PDF

A clustering method using the Coulomb Energy Network (쿨롱네트워크를 이용한 집락분석)

  • 이석훈;박래현;김응환
    • The Korean Journal of Applied Statistics
    • /
    • v.8 no.1
    • /
    • pp.39-50
    • /
    • 1995
  • This article deals with the problem that all the statistical clustering methods do not supply the clustering rule after the analysis. We modify the Coulomb Energy Network model basically developed in physics and suggest one model appropriate for our purpose and show the implementation using an actual data. Finally the method suggested is compared with one of the well known methods, K-means algorithm using Rand C.

  • PDF

The Study on Cooling Load Forecast using Neural Networks (신경회로망을 이용한 냉방부하예측에 관한 연구)

  • 신관우;이윤섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.8
    • /
    • pp.626-633
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity, The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data is approached to the actual data.

The Study on Cooling Load Forecast of an Unit Building using Neural Networks

  • Shin, Kwan-Woo;Lee, Youn-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.170-177
    • /
    • 2003
  • The electric power load during the summer peak time is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. The method of forecasting the cooling load using neural network is also suggested. The daily cooling load is mainly dependent on actual temperature and humidity of the day. The simulation is started with forecasting the temperature and humidity of the following day from the past data. The cooling load is then simulated by using the forecasted temperature and humidity data obtained from the simulation. It was observed that the forecasted data were closely approached to the actual data.

Case Study: Restructuring of the Logistics Network and Calculating of the Distribution Center Size Based on Simulation Method (시뮬레이션을 활용한 신 물류체계 구축과 물류센터 규모 산정에 관한 연구)

  • Jeong, Suk-Jae;Kim, Kyung-Sup;Lee, Jae-Jun;Chung, Tae-Won;Park, Young-Jae
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2005.05a
    • /
    • pp.64-73
    • /
    • 2005
  • 회사의 물류네트워크는 예측된 수요를 바탕으로, 생산, 재고, 수송 등을 고려하여 최적의 거점(Node)와 수배송(Link)를 결정하는 문제로 정의된다. 본 연구에서는 전국적으로 3개의 생산공장과 2개의 물류센터를 보유하고 있으며, 향후 공장이전 및 신규 물류센터를 계획하고 있는 A 페인트사에 대해 현 배송체계를 유지하면서 최적의 물류체계를 구축하는 방안을 모색하고자 한다. 가능한 대안 시나리오를 설정하고, 각 시나리오를 분석하기 위해 시뮬레이션 모델을 구축하였다. 시뮬레이션 분석은 향후 A 페인트사의 적정 물류네트워크 구축 및 물류센터 산정을 결정하는 데 의미있는 결과를 제시하고 있다.

  • PDF

Design of the Protocol for Wireless Charging of Mobile Emotional Sensing Device (모바일 감성 센싱 단말기의 무선 충전을 위한 프로토콜 설계 및 구현)

  • Kim, Sun-Hee;Lim, Yong-Seok;Lim, Seung-Ok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.2
    • /
    • pp.95-101
    • /
    • 2012
  • In order to supply emotion service depending on user's emotional change in a mobile environment, various researches have been carried. This paper discusses a protocol for wireless charging and an embedded platform of the mobile emotional sensing device which supports that. Wireless charging process relieves user's vexatious task to charge the emotional sensing device. To support wireless charging, there are one basestation and several mobile devices. Basestation coordinates and controls the devices over wireless communication, as well as supplies energy. For 1:N communication we defines the network whose superframe is classified into four categories: a network join superframe, a charging request superframe, a charging superframe and an inactive superframe. Physical layer provides how to supply energy to the devices and communicate physically. Mobile device is equipped with energy charged circuits, which correspond with the defined energy supplying method, as well as bidirectional communication circuits. Mobile device monitors and analyzes its own battery status, and is able to send a request packet to basestation. Therefore, it can be charged before its battery is exhausted without user's perception.

Development and application of DMA monitoring system to reduce water losses in water supply network (상수도 관망의 유수율 향상을 위한 블록감시제어시스템 구축 및 활용에 관한 연구)

  • Yoon, Moon-Jung;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2989-2998
    • /
    • 2010
  • This study proposes the DMA(District Metered Area) operation technologies to reduce water losses in water supply network, such as development of DMA control and monitoring system and analysis method of DMA water flow and pressure analysis. DMA boundary analysis and control and monitoring systems of J city was studied in advance, and some problems to be improved was presented. Water losses analysis program was developed to assess the effects of this study.