• Title/Summary/Keyword: superficial velocity

Search Result 129, Processing Time 0.03 seconds

A Study on Aerobic Fluidized-Bed Biofilm Reactor for Treating Industrial Wastewaters(III) -Mathematical model for organic removal- (산업폐수처리를 위한 호기성 생물막 유동층 반응기의 연구(III) -유기물 제거에 관한 수학적 모델-)

  • 안갑환;박상준;송승구
    • Journal of Environmental Science International
    • /
    • v.2 no.4
    • /
    • pp.331-336
    • /
    • 1993
  • A mathematical model for organic removal efficiency was investigated in a fluidized bed biofilm reactor by changing the feed flow rate, the residence time and the recycle flow rate. In batch experiment, organic removal could be assumed as first order and an intrinsic first order rate constant(k1) was found $6.4{\times}^{-6}cm^3/mg{\cdot}sec$ at influent COD range of 3040 - 6620 mg/L. In continuous experiment, at the condition of the influent COD, 3040 mg/L, the superficial upflow velocity, 0.47 cm/sec, the biofilm thickness 336 ${\mu}m$ and the biofilm dry density 0.091 g/mL, the calculated COD removal efficiency from the mathematical model gave 60% which was very close to the observed value of 66 %. As the feed flow rate was increased, the COD removal efficiency was sharply decreased and at constant feed flow rate, the COD removal efficiency was decreased also as the residence time being decreased.

  • PDF

Fluidized Bed Drying Effect on the Aerogel Powder Synthesis

  • Hong, Seong-Hoon;Lee, Dong-Kyu;Oh, Chang-Sup;Kim, Yong-Ha
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.43-46
    • /
    • 2012
  • A fluidized bed drying approach was utilized to the synthesis of water glass based silica aerogel powders. The effects of the fluidized bed drying conditions such as the superficial velocity and temperature of hot air and bead size as well as bead/wet-gel ratio, on the physical properties such as tapping density and productivity of the aerogel powders were systematically investigated. The experimental results showed that the amount of beads mixed with wet-gels in the fluidized bed column has the most profound impact on the fluidization efficiency, greatly enhancing the yield of the aerogel powders up to 98% with a proper bead/wet-gel weight ratio as compared to 72% without using beads. No significant change was observed in the tapping density over a wide range of the fluidized drying condition. Consequently the fluidized bed drying approach shows a good promise as an alternative route for the large-scale production of the aerogel powders.

PREDICT10N OF THE ONSET OF SLUG FLOW IN NEARLY HORIZONTAL AIR-WATER COUNTERCURRENT FLOW

  • Yu, Seon-Oh;Chun, Moon-Hyun;Kim, Yang-Seok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.368-373
    • /
    • 1997
  • The transition from a statified wavy to a slug flow has been analyzed considering the mechanistic forces acting on the wave crest in a nearly horizontal air-water countercurrent flow. To verify the results of the analysis, a series of experiments have been performed changing the inclination angle of the test section. Comparisons of the theoretical predictions with experimental data show a good agreement and the results show that the present model gives similar results of Taitel and Dukler's in the case of inclined pipes. However, at high superficial liquid velocity, the results of present work agree more closely with data than that of Taitel and Dukler's. Also, predictions of the present model gives a very close agreement with the experimental data for various tube sizes obtained by others.

  • PDF

Interfacial Wave Characteristics for Countercurrent Stratified Air-Water Flow in a Horizontal Pipe

  • Chung, Heung-June;Chun, Se-Young;Chung, Moon-Ki;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.379-389
    • /
    • 1996
  • To experimentally investigate the several wave patterns for the horizontal countercurrent stratified air-water flow, a series of systematic experimental studies have been performed. The experiments are carried out in a horizontal pipe with 4m in length and 102mm in inner diameter. The oater and air superficial velocities vary from 0.0004 to 0.0204 and from 0 to 6m/s, respectively. The instantaneous water thickness is measured by parallel-wire conductance probes, and the wave field is recorded by high speed video camera. Also, to evaluate the wave effect on interfacial friction factor, the pressure drop is measured. Statistical data anal)sis is accomplished in order to obtain the fundamental wave parameters such as un amplitude, length and velocity, and spatial growth factor. By using these statistical parameters, the wave regime boundaries can be verified.

  • PDF

Fractional gas hold-up in trayed bubble column (Trayed 기포탑 반응기에서 높이에 따른 기포입자의 거동분석)

  • Yang, Jung Hoon;Hur, Young Gul;Yang, Jung-Il;Kim, Hak-Joo;Chun, Dong Hyun;Kim, Byung Kwon;Lee, Ho-Tae;Jung, Heon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.77.1-77.1
    • /
    • 2011
  • 슬러리 기포탑 반응기는 열 및 물질 전달의 용이성, 낮은 운전비용 및 장치의 간단성의 장점을 가지고 있어서 Fischer-Tropsch 반응, bio-reaction 등에 많이 응용되고 있다. 특히, 반응물은 기체 상태로 반응기에 투입이 되는데, 이 기포입자의 상승하는 힘을 바탕으로 기상/액상/고상이 균일하게 혼합되게 된다. 많은 연구자들이 이러한 기포탑 반응기의 성능을 개선하고자, 다양한 반응기 디자인에 대하여 보고하고 있다. 특히 반응기 내부에 tray를 설치함으로써, 기포 포집율을 증진시기고 액상의 역류를 최소화시키는 연구가 활발히 진행되고 있다. 본 연구에서는, 다양한 기공크기를 갖는 tray를 활용함으로써 높이에 따른 기포 포집율의 변화 및 반응기 내에 기포 입자의 거동 특성에 대하여 살펴보았다.

  • PDF

The Effect of Air Vent Holes and Stacking Methods of Fruits and Vegetables Boxes on Static Pressure Drop in Pressure Cooling System (청과물상자의 통기공 및 상자적재방법이 정압강하에 미치는 영향)

  • 김의웅;김병삼;남궁배;정진웅;김동철;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.20 no.4
    • /
    • pp.360-367
    • /
    • 1995
  • The effect of air vent holes, stacking methods of boxes and clearance between boxes on static pressure drop, were measured to design of pressure cooling system. Static pressure drops in air vent hole of carton box were measured for different hole opening ratio from 1% to 5%. Static pressure drop was expressed as a function of superficial velocity as second-degree polynomial. At given static pressure in plenum chamber, static pressure drop in boxes was shown as second-degree polynomial of the number of carton box in series stacking method, as first-degree polynomial in height and parallel stacking method. In pressure cooling of 24 boxes of Tsugaru apple, air flow rates through clearance between the boxes were shown 1.27 and 1.65 times than those of through the inside of boxes at the plenum pressure of 10mmAq and 20mmAq, respectively.

  • PDF

Applicability of One-Dimensional Mechanistic Post-Dryout Prediction Model

  • Jeong, Hae-Yong;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.586-591
    • /
    • 1996
  • Through the analysis of many experimental post-dryout data, it is shown that the most probable flow regime near dryout or quench front is not annular flow but churn-turbulent flow when the mass flux is low. A correlation describing the initial droplet size just after the CHF position at low mass flux is suggested through regression analysis. In the post-dryout region at low pressure and low flow, it is found that the suggested one-dimensional mechanistic model is not applicable when the vapor superficial velocity is very low, i.e., when the flow is bubbly or slug flow regime. This is explained by the change of main entrainment mechanism with the change of flow regime. Therefore, the suggested correlation is valid only in the churn-turbulent flow regime ( $j_{g}$ $^{*}$=0.5~4.5).).

  • PDF

Effect of the Gravity Forces on Flow Pattern and Frictional Pressure Drop in Two-Phase, Two-Component Flow

  • Choi, B.-H;Han, W.-H
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.338-346
    • /
    • 2004
  • Experimental data on the effect of the variable gravity magnitude, namely microgravity, normal gravity and hyper-gravity, on flow pattern and frictional pressure drop were obtained during co-current air-water flow in a horizontal tube, The flow patterns were found to depend strongly on the gravity magnitude and certain flow pattern were found to depend on the gas superficial velocity. The effect of the gravity magnitude had an effect on the frictional pressure drop only at low flow rates. The present data are used to evaluate some of existing flow pattern transition and pressure drop models and correlations.

Effect of Invertase on a Batch Foam Fractionation of Bromelain

  • Park, Don-Hee;Jr., Douglas.M.Ackermann;Stedman, Matthew.L.;Ko, Samuel;Prokop, Ale;Tanner, And Robert D.
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.515-518
    • /
    • 2002
  • The method of foam fractionation can be applied to enrich proteins from a dilute protein solution if the proteins are hydrophobic and foam. If a protein, such as invertase, is hydrophilic, a dilute solution containing this protein may not foam. In that case, a batch foam fractionation process may not be appropriate for recovering a concentrated solution of that protein. In this paper, various concentrations of invertase were added to a dilute solution containing bromelain (a hydrophobic protein), in order to determine how the presence of a hydrophilic protein can affect the recovery of the desired hydrophobic protein. The effect of invertase on bromelain recovery was studied here at an initial bulk solution pH of 5 and an air superficial velocity of 4.6 cm/s.

  • PDF

The Effective Factors of n Foam Generation Using Foam Condensate (포말 농축물에 의한 포말 생성의 영향인자)

  • SUH Kuen-Hack;SHIN Jeong-Sik;LEE Ju-Hwa
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.509-514
    • /
    • 2003
  • We performed the experiment to determine the effective factors, such as the initial concentration of protein, pore size of air distributor, SAV (superficial air velocity), pH, salts and temperature related to foaming characteristics. The foam height in a foam generator was increased with the increase of the initial protein concentration and the decrease of pore size. As SAV was increased, the foam height was increased, and the optimum SAV was 0.84 cm/sec. The foam height was highest in the acid region and it was increased with the increase of salt concentration of NaCl and $NaHCO_3.$ The removal efficiencies of TSS (total suspended solid) and turbidity decreased with the increase of the initial protein concentration in the batch foam separator.