• Title/Summary/Keyword: superficial velocity

Search Result 129, Processing Time 0.025 seconds

Development of a 9as-liquid two-phase flowmeter using double orifice plates (2중판 오리피스를 이용한 기액 2상유량계의 개발)

  • 이상천;이상무;남상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF

Photocatalytic Decolorization of Dye usingUV/TiO2 and Fluidized Bed Reactor (UV/TiO2와 유동층 반응기를 이용한 안료의 광촉매 탈색)

  • Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.921-928
    • /
    • 2004
  • The photocatalytic decolorization of Rhodamine B (RhB) was studied using immobilized $TiO_2$ and fluidized bed reactor. Immobilized $TiO_2$(length: 1$\~$2 mm, width: 1$\~$3 mm, thickness: 0.5$\~$2 mm) onto silicone sealant was employed as the photocatalyst and a 30 W germicidal lamp was used as the light source and the reactor volume was 4.8 L. The effects of parameters such as the amounts of photocatalyst, initial concentration, initial pH, superficial velocity, $H_2O_2$ and anion additives. ($NO_3^{-},\;SO_4^{2-},\;Cl^{-},\;CO_3^{2-}$) The results showed that the optimum dosage of the immobilized $TiO_2$ were 87.0 g/L. Initial removal rate of RhB of the immobilized $TiO_2$ was 1.5 times higher than that of the powder $TiO_2$ because of the adsorption onto the surface of immobilized $TiO_2$ In the conditions of acidic pH, initial reaction rate was increased slowly and reaction time was shorted. The effect of anion type on the reaction rate was not much.

An Experimental Study on Regime Limit and Pressure Drop of Dry-plug Flow in Round Mini-channels (원형 미소 채널 내 드라이 플러그류의 유동 영역 한계와 압력 강하에 관한 실험적 연구)

  • Lee, Chi-Young;Lee, Sang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2583-2588
    • /
    • 2008
  • In the present experimental study, the regime limit and pressure drop of dry-plug flow (dry wall condition at the gas portions of plug flow) in round mini-channels has been investigated. The air-water mixture was flowed through the round mini-channels made of Teflon, where the tube diameters ranged from 1.26 to 2.06 mm. For the present experimental range, with decreasing of the tube diameter, the transition between the plug and slug flows (wet and dry) happened at the higher gas superficial velocity region, which were in good agreement with the previous flow pattern maps tested. On the other hand, the transition between the wet- and dry-plug flows was little affected by the change of the tube diameter. In the pressure drop of dry-plug flows, among the correlations tested, the Lee and Lee's (2008) correlation best fitted the measured pressure drop data within the mean deviation of 10% for the present experimental range.

  • PDF

The Effects of Two - Phase Swirling Flow on Void Distribution and Pressure Drop in a Vertical Tube (수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향)

  • Kim, I.S.;Son, B.J.;Shin, H.D.;Kwack, K.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.190-201
    • /
    • 1989
  • This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.

  • PDF

Study on the Characteristics of Bubble and Liquid Slugs for Gas-Liquid Taylor Flow in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor Flow의 기포 및 액체 슬러그 유동 특성에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.520-526
    • /
    • 2015
  • The characteristics of gas-liquid Taylor (Slug) flow in a square micro-channel of $600{\sim}600{{\mu}m}$ were investigated experimentally in this paper. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~3 m/s and 0.1~3 m/s, respectively. Bubble and liquid slug length, bubble velocity, and frequency were measured by analyzing optical images using a high speed camera. Bubble length decreased with higher liquid flow rate, which increased dramatically with higher gas flow rate. However, slug length did not vary with changes in inlet liquid conditions. Additionally, bubble velocities and frequencies increased with higher liquid and gas flow rates. It was found that measured bubble lengths were in good agreement with the empirical models in the existing literature, but slug lengths were not.

A Kinetic Study with Biomass Characteristics in Fluidized-Bed Biofilm Reactor. (생물막 유동층 반응기에서 미생물 성상에 따른 속도론적 고찰)

  • 김동석;안갑환이민규송승구
    • KSBB Journal
    • /
    • v.6 no.2
    • /
    • pp.115-121
    • /
    • 1991
  • A number of experiments were conducted in order to investigate the COD removal rate according to the biofilm thickness in a Fluidized-Bed Biofilm Reactor(FBBR). The following conditions were fixed during the experiments: superficial upflow velocity was 0.47cm/sec, operating temperature was $22{\pm}1{\circ}C$ and pH was about $7{\pm}0.1$. The synthetic wastewater based on glucose was used as a substrate. The COD removal efficiencies were shown as 73% and 95%, respectively, when organic loading rate was increased from $10kgCOD\;/\;{\textrm{m}^3}$.day to $80kgCOD\;/\;{\textrm{m}^3}$.day. Andrew's model of substrate removal rate which was commonly used in fixed-biofilm reactor was transformed and applied in this FBBR experiment to predict substrate removal rate and gave 85% agreement with the experimental values.

  • PDF

Posterior Interosseous Nerve Palsy Caused by a Ganglion of the Arcade of Frohse

  • Lee, Seung Jin;Hyun, Yoon Suk;Baek, Seung Ha;Seo, Ji Hyun;Kim, Hyun Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.252-255
    • /
    • 2018
  • A 51-year-old male who is right-handed visited the outpatient for right fingers-drop. The patient's fingers, including thumb, were not extended on metacarpophalangeal joint. The active motion of the right wrist was available. The electromyography and nerve conduction velocity study were consistent with the posterior interosseous neuropathy. Further evaluation was done with the magnetic resonance imaging for finding the space-occupying lesion or any possible soft tissue lesion around the radial nerve pathway. On magnetic resonance imaging, the ganglion cyst, which was about 1.8 cm in diameter, was observed on the proximal part of the superficial layer of the supinator muscle (Arcade of Frohse). The surgical excision was done on the base of ganglion cyst at the base of stalk of cyst which looked to be connected with proximal radioulnar joint capsule. The palsy had completely resolved when the patient was observed on the outpatient department a month after the operation.

Corrosion behavior and mechanism of CLAM and 316L steels in flowing Pb-17Li alloy under magnetic field

  • Xiao, Zunqi;Liu, Jing;Jiang, Zhizhong;Luo, Lin;Huang, Qunying
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.1962-1971
    • /
    • 2022
  • The liquid lead-lithium (Pb-17Li) blanket has many applications in fusion reactors due to its good tritium breeding performance, high heat transfer efficiency and safety. The compatibility of liquid Pb-17Li alloy with the structural material of blanket under magnetic field is one of the concerns. In this study, corrosion experiments China low activation martensitic (CLAM) steel and 316L steel were carried out in a forced convection Pb-17Li loop under 1.0 T magnetic field at 480 ℃ for 1000 h. The corrosion results on 316L steel showed the characteristic with a superficial porous layer resulted from selective leaching of high-soluble alloy elements and subsequent phase transformation from austenitic matrix to ferritic phase. Then the porous layers were eroded by high-velocity jet fluid. The main corrosion mechanism of CLAM steel was selective dissolution-base corrosion attack on the microstructure boundary regions and exclusively on high residual stress areas. CLAM steel performed a better corrosion resistance than that of 316L steel. The high Ni dissolution rate and the erosion of corroded layers are the main causes for the severe corrosion of 316L steel.

Improving Biomass Productivity of Freshwater microalga, Parachlorella sp. by Controlling Gas Supply Rate and Light Intensity in a Bubble Column Photobioreactor (가스공급속도 및 광도조절을 이용한 담수미세조류 Parachlorella sp.의 바이오매스 생산성 향상)

  • Z-Hun Kim;Kyung Jun Yim;Seong-Joo Hong;Huisoo Jang;Hyun-Jin Jang;Suk Min Yun;Seung Hwan Lee;Choul-Gyun Lee;Chang Soo Lee
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.41-48
    • /
    • 2023
  • The objective of the present study was to improve the biomass productivity of newly isolated freshwater green microalga Parachlorella sp. This was accomplished by culture conditions optimization, including CO2 concentration, superficial gas velocity, and light intensity, in 0.5 L bubble column photobioreactors. The supplied CO2 concentration and gas velocity varied from 0.032% (air) to 10% and 0.02 m/s - 0.11 m/s, respectively, to evaluate their effects on growth kinetics. Next, to maximize the production rate of Parachlorella sp., a lumostatic operation based on a specific light uptake rate (qe) was applied. From these results, the optimal CO2 concentration in the supplied gas and the gas velocity were determined to be 5% and 0.064 m/s, respectively. For the lumostatic operation at 10.2 µmol/g/s, biomass productivity and photon yield showed significant increases of 83% and 66%, respectively, relative to cultures under constant light intensity. These results indicate that the biomass productivity of Parachlorella sp. can be improved by optimizing gas properties and light control as cell concentrations vary over time.

Correlation of the Lower Limb Nerve Conduction Velocity with Height and Leg Length (한국인에서 신장과 다리길이에 따른 하지 신경전도검사속도의 상관관계조사)

  • Jae-Hwan SONG;Sung-Hee KIM;Dae-Hyun KIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.2
    • /
    • pp.156-162
    • /
    • 2024
  • Nerve conduction study (NCS) is an essential test for the diagnosis and follow-up of peripheral neuropathy. NCS can objectively quantify peripheral nerve function. NCS is affected by physiological factors such as height, age, body mass index, etc. Hence, the American Association of Neuromuscular & Electrodiagnosis Medicine (AANEM) is currently forming a Normal Data Task Force (NDTF) to present the normal value, but the number is significantly less. Currently, no research has been carried out on the correlation between nerve conduction speed and height and lower limb length in Koreans. Hence, this study sought to compare the nerve conduction velocity of the lower limbs according to the height and lower limb length. A total of 49 subjects were recruited. When the motor nerve conduction velocity and sensory nerve conduction velocity were compared according to the height and leg length, there was a statistically significant negative correlation of the peroneal and left tibial motor nerves with the height. Also, a statistically significant negative correlation was observed with the superficial peroneal sensory nerve and the sural nerve and the leg length. However, in this study, all the subject are in twentys age, whereas the NDTF is divided by age. Hence, additional studies involving subjects of various age groups are needed.