• Title/Summary/Keyword: superconducting tape

Search Result 307, Processing Time 0.027 seconds

Improvement of Critical Current In Bi-2223/Ag HTS Tapes by the Bubbling Control

  • 하홍수;오상수;하동우;이남진;김상철
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.247-251
    • /
    • 2002
  • In general, the bubbling, generated during the fabrication of the tapes, breaks the superconducting filament, and critical current of the tapes will be decreased. Heat-treatment schemes of Bi-2223/Ag HTS tapes were modified, such as pre-annealing of multi-stacked billet, 2-step main sintering and ramp rate etc. The generation of bubbling was drastically decreased from 20 bubbles/m to 0 ~ 1 bubble/m by the modified heat-treatment. Therefore, the value of critical current of the tapes without bubbling was increased almost twice higher than that of already existing tapes. Critical current up to 42 A in 40 m length Bi-22231Ag tapes have been measured at 77K, self-field, 1$mutextrm{V}$/cm criterion. It could be confirmed that elimination of bubbling is effective to maintain the superconducting property along the tape length.

  • PDF

PREPARATION OF $Y_1Ba_2Cu_3O_y$ SUPERCONDUCTING TAPE BY VAPOR DEPOSITION TECHNIQUES

  • Maeda, Hiroshi
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.2
    • /
    • pp.67-72
    • /
    • 1991
  • The feasibility of preparing superconducting $Y_1Ba_2Cu_3O_y$ films on metallic substrate was exmined in an attempt to fabricate a tape conductor. Deposition methods employed were sputtering, laser ablation, and plasma flash evaporation. Although zero resistance temperature (Tc) is achieved above 90 K, critical current density values (Jc) obtained so far is still low as compared with those reported in the films grown on single crystal substrates. This may be caused by the misalignment of the crystal structure of the films on metal substrates. A further improvement if Jc for highly-oriented polycrystalling films is being investigated at the present time.

  • PDF

Study on transport current properties on YBCO Coated Conductor According to aspect of type formers (Former의 형상에 따른 YBCO Coated Conductor의 사고전류 통전 특성 분석)

  • Kim, Min-Ju;Du, Ho-Ik;Doo, Seung-Gyu;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.357-358
    • /
    • 2009
  • YBCO Coated Conductor is named by Second generation Superconductor Tapes. It is different with First generation Superconductor Tapes. YBCO Coated Tape's Specific difference with BSCCO Tape is more strong mechanical Durability. This is important role to apply to Superconducting Machines. For mechanical transforming of YBCO Coated Tapes, We are using the well designed former. The Merit of Transformation is several. First, We vary the Superconducting Characteristics according to mechanical stress. Second, We reduce the Volume of Superconductor, So We achieve reducing the volume of Superconducting Machines. On this Study, We experiment the transporting Current Characteristics of two types YBCO Coated Conductor. The one is Stainless Stabilized YBCO Conductor, and the other one is Copper Stabilized YBCO Conductor.

  • PDF

Study on the Stability Evaluation of the High-Tc Superconducting Power Cable (고온초전도 전력케이블의 안정도 평가를 위한 교류손실에 관한 연구)

  • Bae, J.H.;Choi, S.J.;Lee, S.J.;Cho, J.W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1236-1240
    • /
    • 2007
  • In order to evaluate if the high-Tc superconducting(HTS) power cable is operating stably, the characteristics of the HTS power cable should be found out. The properties of HTS tapes by measuring the voltage with respect to the current can be archived. But, the HTS power cable is different from the case of HTS tapes. This method is invalid because of the electromagnetic fields caused by other HTS tapes. In this paper, the stability evaluation of the HTS cable was performed by the following procedure. First, the voltage-current characteristics of HTS tape were measured and the electromagnetic field distributions of the HTS power cable with the external magnetic field were analyzed. Second, the losses of the HTS power cable were calculated using the result of the measurement and the analysis. Finally, the stable operation of the HTS power cable was evaluated on the basis of the losses of the superconducting cable.

Numerical Analysis of Transport Current Losses in Stacked HTS Conductors (적층 형태의 고온 초전도선재에서의 통전손실 수치 해석)

  • 최세용;나완수;김정호;주진호;류경우
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • We have studied alternating transport current losses in the vertically stacked high temperature superconducting tapes(HTS) using numerical techniques. In the case of stacked conductors, HTS tapes are exposed to self-field generated by transport current itself and also experienced external magnetic field around adjacent tapes. It is well known that magnetic interactions between neighbored tapes have significant effect on their properties of superconducting tapes such as current distribution, AC loss, and critical current. In this paper, we investigated the transport current losses in stacked conductors consisting of a few of the HTS tapes using numerical analysis. Current distributions are calculated in HTS tape cross-section taking account of magnetic field dependencies, which are represented superconducting nonlinear properties. Dissipated losses in tape and stacked conductors were integrated with current distribution and electric field intensity in the whole conductor region. Finally estimated results were discussed and verified through the analytical theory.

  • PDF

Current Limitation by Bi-2223 Bifilar Winding Coils

  • Ahn Min Cheol;Bae Duck Kweon;Park Dong Keun;Yang Seong Eun;Yoon Yong Soo;Ko Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.31-34
    • /
    • 2005
  • There are many kinds of high temperature superconducting (HTS) application using Bi-2223 tape which is the most commercialized HTS material. Also, resistive superconducting fault current limiters (SFCLs) have been developed using many kinds of superconducting material such as YBCO thin film, Bi-2212 bulk and so on. However, SFCL using Bi-2223 tape has never been developed. This paper deals with the feasibility study on SFCL using Bi-2223 wire. The over-current behaviors of Bi-2223 short-length sample were measured. To make the resistive SFCL, two small-scale bifilar winding modules using 7m Bi-2223 wire were fabricated; i.e. solenoid type bifilar coil and pancake type one. The short-circuit tests of the coils were successfully performed up to 16 V$_{rms}$ From these tests, the current limiting capabilities of Bi-2223 bifilar coils were confirmed and current limiting performances between two winding types were compared. In addition, the feasibility of resistive SFCL using another HTS wire, i.e. YBCO coated conductor, was also investigated.

Optimization of wire construction from several 2G HTS tapes

  • Kumarov, D.R.;Sotnikov, D.;Scherbakov, V.I.;Mankevich, A.;Molodyk, A.;Sim, Kideok;Hwang, Soon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.4
    • /
    • pp.24-28
    • /
    • 2019
  • Despite the second generation HTS tapes (2G HTS tape) have limits in critical current value, scientific and electric devices require more current density day after day. These requirements are realized by using different superconducting wires that consist of 2G HTS tapes designed in various combinations. Authors of this paper have developed the numerical model for estimation of total critical current in the superconducting wire and critical current in each 2G HTS tape placed in this superconducting wire. The current drop in six 2G HTS tapes having different constructions was analyzed. The result of this research is the decrease of critical current up to 25 % for the stack of tapes and up to 5 % for the parallel tapes in the same plane. In addition, what was also made is the estimation of the current distribution by length for six 25 m 2G HTS tapes in different constructions and determination of current deviation by length of the wire.

position marking technique for data measured in a scanning hall probe system (스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술)

  • Yoo, Jae-Un;Lee, Jae-Young;Jung, Ye-Hyun;Lee, Sang-Moo;Youm, Do-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.

Critical Current Properties of Bi-2223/Ag tapes with respect to axial Strain (Bi-2223/Ag 고온 초전도 선재 변형에 따른 입계전류 특성)

  • 하홍수;오상수;하동우;심기덕;김상철;장현만;권영길;류강식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.1
    • /
    • pp.69-73
    • /
    • 2001
  • In this study, we fabricated Bi-2223/Ag high temperature superconducting tapes using PIT(Powder-In-Tube) process to apply the superconducting magnet, cable and etc. It is inevitable to deform the superconducting taps with axial strain for application. Therefore, for the characterization of the strain sensitivity of the superconducting properties, the degradation of Bi-2223/Ag tapes due to axial strain were investigated by measuring the critical current as a function of applied tension strain and external magnetic field. The critical current of Bi-2223/Ag tapes were decreased slightly up to 0.3∼0.4% applied strain but, drastically decreased more than these strains. Superconducting filament cores consisted of brittle ceramic fibers were broken easily by the large strain and current path were decreased simultaneously.

  • PDF

Fabrication of superconducting Joints Between PIT Processed BSCCO 2223 Tapes by Single and Multiple Press & reaction Annealing (고온초전도 BSCCO 2223 선재간의 초전도 접합부 제조연구)

  • Yu, Jae-Mu;Go, Jae-Ung;Jeong, Hyeong-Sik
    • 연구논문집
    • /
    • s.27
    • /
    • pp.175-181
    • /
    • 1997
  • Superconducting joints between Bi-2223/Ag tapes are fabricated by a press & reaction anneal and a multiple press & anneal. The silver sheath was mechanically or chemically removed from one side of each tape without altering the superconducting core. The exposed superconducting core of the two tapes were brought into contact and pressed so as to form a lap joint. The joined tapes were then subjected to a series of different thermomechanical treatments to achieve optimum heat treatment condition. The result from transport measurements shows that critical current ($I_c$) transmitting through joined area reaches 9A, approximately 60% of the current capacity of the tapes themselves. The critical current through joined area was improved by repeated press and reaction annealing. Measurements of the current-voltage relationship were made with several configuration of the voltage probes to characterize the critical current variation and I-V curve along the joint. Also discussed are microstructural aspects of the superconducting joint.

  • PDF