Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권4호
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

Establishment of CTE Measurement Procedure for PPLP at 77 K for HTS Power Cables using Double Extensometers

  • Dedicatoria, Marlon J.;Dizon, John Ryan C.;Shin, Hyung-Seop;Sim, Ki-Duk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.24-27
    • /
    • 2012
  • The measurement of the coefficient of thermal expansion (CTE) of polypropylene laminated paper (PPLP) as electric insulating material is important for its practical superconducting device application. The thermal strain induced to HTS tapes and its insulating material during cooling from room temperature might largely affect the critical current ($I_c$) of HTS tapes. In this study, the thermal contraction of PPLP material was measured during cooling from 300 K to 77 K using double extensometers. Initially, the CTE of a brass tape was measured and it was compared with a reference data. It was found that the measured thermal expansion data of the brass material approaches that of the reference one. Based on the results, it was then confirmed that the measurement technique could be applied to thin and flexible samples. Therefore, the same measurement procedure was applied to PPLP material using double extensometers. As a result, the linear CTE of the PPLP at 77 K has been measured to be ${\sim}15.3{\times}10^{-6}/K$. Also, it was found that the thermal contraction characteristics of PPLP was dominated by polypropylene on the cross direction (higher thermal contraction) while it was dominated by Kraft paper on the machine direction (lower thermal contraction). Overall, this measurement procedure could be adopted for the determination of CTE of flexible materials such as PPLP.

단상 1MVA 고온초전도 변압기의 누설임피던스 3차원 해석 및 시험 (Test and Analysis of 3-D of Leakage Impedances in a Single-Phase 1MVA HTS Transformer)

  • 김성훈;김우석;이상진;최경달;주형길;홍계원;한진호;한송엽;송희석;박정호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1003-1005
    • /
    • 2003
  • In this paper, 3-D nonlinear electromagnetic analysis of a single phase 1MVA 22.9 kV/6.6 kV high temperature superconducting(HTS) transformer with double pancake windings was accomplished. The characteristics of 1MVA HTS transformer such as The efficiency, voltage regulation and % impedance voltage drop were obtained by the 3-D non-linear electromagnetic analysis. And in order to verify the 3-D non-linear electromagnetic analysis of a single phase 1MVA HTS transformer, a 1MVA test transformer with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The energy conservation method to perform the analysis of leakage impedances of both a 1MVA HTS transformer and test transformer was used. The characteristic analysis such as efficiency, voltage regulation and % impedance voltage drop of transformer was performed. And the obtained values of both 1MVA HTS transformer and test transformer were compared.

  • PDF

초전도 테이프 제작을 위한 니켈기판상의 산화물 박막증착에 대한 연구 (Study on depositing oxide films on Ni substrate for superconducting tape)

  • 김호섭;;정준기;하홍수;고락길;최수정;박유미;송규정;염도준;박찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.531-534
    • /
    • 2004
  • 초전도 coated conductor는 보호층/초전도층/완충층/금속기판의 구조를 가지며 완충층은 다층산화물 박막으로 이루어져 있다. 본 연구에서는 니켈 기판의 원자가 초전도층으로 확산 침투하는 것을 방지하는 YSZ(Yttria Stabilized Zirconia) 박막의 증착방법 및 최적조건에 대하여 소개하고자 한다. 금속타겟을 사용하며 산화반응가스로서 수증기를 사용하는 것을 특징으로 하는 DC reactive sputtering을 이용하여 YSZ를 증착하였으며 기판 온도는 $850^{\circ}C$ 이며 증착시 수증기 분압은 1mTorr이었다. YSZ의 최적두께를 알아보기 위하여 $CeO_2(12.2nm)/Ni$ 상부에 130nm, 260nm, 390nm, 650nm로 두께를 달리하여 YSZ층을 증착하고 SEM으로 박막 표면상태를 관찰한 결과 columnar grain growth를 하며 두께가 두꺼워 질수록 표면조도가 증가함을 알 수 있었다. 4개의 각 시료위에 thermal evaporation 증착법을 이용하여 $CeO_2$를 18.3nm의 두께로 증착한 후 PLD를 이용하여 YBCO 초전도 박막을 300nm 두께로 증착하였고 77K, 0T에서 임계전류가 각각 0, 6A, 7.5A, 5A로 측정되었다. 이는 YSZ층의 두께가 두꺼워질수록 기판 구성원자의 확산방지역할을 충실히 하는 반면에 표면조도는 증가함을 알 수 있었다.

  • PDF

The fabrication of bulk magnet stacked with HTS tapes for the magnetic levitation

  • Park, Insung;Kim, Gwantae;Kim, Kyeongdeok;Sim, Kideok;Ha, Hongsoo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권3호
    • /
    • pp.47-51
    • /
    • 2022
  • With the innovative development of bio, pharmaceutical, and semiconductor technologies, it is essential to demand a next-generation transfer system that minimizes dust and vibrations generated during the manufacturing process. In order to develop dust-free and non-contact transfer systems, the high temperature superconductor (HTS) bulks have been applied as a magnet for levitation. However, sintered HTS bulk magnets are limited in their applications due to their relatively low critical current density (Jc) of several kA/cm2 and low mechanical properties as a ceramic material. In addition, during cooling to cryogenic temperatures repeatedly, cracks and damage may occur by thermal shock. On the other hand, the bulk magnets made by stacked HTS tapes have various advantages, such as relatively high mechanical properties by alternate stacking of the metal and ceramic layer, high magnetic levitation performance by using coated conductors with high Jc of several MA/cm2, consistent superconducting properties, miniaturization, light-weight, etc. In this study, we tried to fabricate HTS tapes stacked bulk magnets with 60 mm × 60 mm area and various numbers of HTS tape stacked layers for magnetic levitation. In order to examine the levitation forces of bulk magnets stacked with HTS tapes from 1 to 16 layers, specialized force measurement apparatus was made and adapted to measure the levitation force. By increasing the number of HTS tapes stacked layers, the levitation force of bulk magnet become larger. 16 HTS tapes stacked bulk magnets show promising levitation force of about 23.5 N, 6.538 kPa at 10 mm of levitated distance from NdFeB permanent magnet.

The physical properties of several HTS coated conductors

  • Lee, Nam-Jin;Oh, Sang-Soo;Song, Kyu-Jeong;Ha, Dong-Woo;Kim, Ho-Sup;Ha, Hong-Soo;Ko, Rock-Kil;Kim, Tae-Hyung;Kim, Sang-Cheol;Yu, Kwon-Kuk;Moon, Seung-Hyun;Youm, Do-Jun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권4호
    • /
    • pp.19-23
    • /
    • 2007
  • The superconducting properties of several HTS coated conductors (CC), which had different tape structures, fabricated by KERI, X and Y institutes were compared. We have fabricated the $high-J_c$ SmBCO CC, which has 273.5 A/cm, $1.2MA/cm^2$ and 93.5 K for $I_C,\;J_C\;and\;T_{c-zero}$, respectively, using the EDDC (Evaporation using Drum in Dual Chambers) process. Both X and Y institutes CCs, however, were purchased. The n-values of KERI, X and Y institutes CCs are 58.5, 40.7 and 31.5 in $V=1{\sim}10{\mu}V$ criterion, respectively. The in-field properties of $I_C$ at 77K were investigated and the $J_C(B)/J_C(0G)$ at 0.5 T with $B{\perp}$ ab-plane are 0.31, 0.19 and 0.24 for KERI, X and Y institutes CCs, respectively. From the $I_C-{\theta}-B$ measurement, we observed that the ab-plane of ReBCO phase was tilted for the ab-plane of substrate in the KERI and X institutes CCs. The tilted angle is about 5 degree. We confirmed that the peak shift (as an inclined texture) was observed by X-ray (102) pole figures of the SmBCO for the KERI CC.

Thermodynamic simulation and structural optimization of the collimator in the drift duct of EAST-NBI

  • Ning Tang;Chun-dong Hu;Yuan-lai Xie;Jiang-long Wei;Zhi-Wei Cui;Jun-Wei Xie;Zhuo Pan;Yao Jiang
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4134-4145
    • /
    • 2022
  • The collimator is one of the high-heat-flux components used to avoid a series of vacuum and thermal problems. In this paper, the heat load distribution throughout the collimator is first calculated through experimental data, and a transient thermodynamic simulation analysis of the original model is carried out. The error of the pipe outlet temperature between the simulated and experimental values is 1.632%, indicating that the simulation result is reliable. Second, the model is optimized to improve the heat transfer performance of the collimator, including the contact mode between the pipe and the flange, the pipe material and the addition of a twisted tape in the pipe. It is concluded that the convective heat transfer coefficient of the optimized model is increased by 15.381% and the maximum wall temperature is reduced by 16.415%; thus, the heat transfer capacity of the optimized model is effectively improved. Third, to adapt the long-pulse steady-state operation of the experimental advanced superconducting Tokamak (EAST) in the future, steady-state simulations of the original and optimized collimators are carried out. The results show that the maximum temperature of the optimized model is reduced by 37.864% compared with that of the original model. The optimized model was changed as little as possible to obtain a better heat exchange structure on the premise of ensuring the consumption of the same mass flow rate of water so that the collimator can adapt to operational environments with higher heat fluxes and long pulses in the future. These research methods also provide a reference for the future design of components under high-energy and long-pulse operational conditions.