• 제목/요약/키워드: super-conducting field winding

검색결과 4건 처리시간 0.017초

개방회로, 단락회로 특성시험 및 부하시험을 이용한 30 kVA 초전도 발전기의 특성해석 (A Study on 30 kVA Super-Conducting Generator Performance using Open Circuit, Short Circuit Characteristics, and Load Tests)

  • 하경덕;황돈하;박도영;김용주;권영길;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권2호
    • /
    • pp.85-92
    • /
    • 2000
  • 30 kVA rotating-field type Super-Conducting Generator is built and tested with intensive FE(Finite Element) analysis. The generator is driven by VVVF inverter-fed induction motor. Open Circuit Characteristic(OCC) and Short Circuit Characteristic(SCC) are presented in this paper. Also, the test result under the light load(up to 3.6 kW) are given. From the design stage, 2-D FE analysis coupled with the external circuit has been performed. The external circuit includes the end winding resistance and reactance as well as two dampers. When compared with the test data, the FE analysis results show a very good agreement.

  • PDF

핵자기공명(NMR) 응용을 위한 고자장 초전도 마그네트의 최적화 설계 (High Field Superconducting Magnet Optimal Design for Nuclear Magnetic Resonance (NMR) Applications)

  • 고락길;조영식;권영길;진홍범;배준한;심기덕;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.150-153
    • /
    • 2000
  • NMR researches are required high field and high homogeneous super-conducting magnet. Thus superconducting magnets for NMR applications are designed with minimization of coil winding volume satisfied constraints such as field strength, field homogeneity, etc. In this paper, we are discussed optimal design of high field super-conducting magnet for NMR applications. For a design example, we designed unshielded superconducting magnet for 600MHz NMR spectrometer with 100mm room temperature bore size and obtained 14.1011[T] field strength and 1.33 ppm field homogeneity.

  • PDF

100 HP급 고온초전도 모터의 설계 및 성능 해석 (A 100 HP HTS Motor Design and the Performance Analysis)

  • 백승규;손명환;김석환;이언용;권영길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.31-37
    • /
    • 2002
  • A 100 〔HP〕 rated synchronous motor with superconducting rotating field winding has been designed based on the formulated equations established from 2 dimensional magnetic field distributions in a cylindrical coordinate The cross-section was drawn based on calculated design results via Fortran program and then modeled with FEM (Finite Element Method) to investigate the machine performances. First of all, the magnetic field distributions are analysed in many ways according to the field directions and the armature currents. Especially after the rotating Held winding is arranged with BSCCO-2223 high-temperature superconducting(HTS) pancake coils, the exerted magnetic field normally on the HTS tape is calculated through FEM. And the machine output power is calculated according to the torque ang1es which lie between the field and the armature main flux lines. Moreover, this Paper includes the eddy-current loss variations of a copper damper located between the field and the armature coils and design considerations of the 100 HP HTS motor utilizing ferro-magnetic material.

보정된 2차원 해석모델에 의한 초전도 동기발전기의 댐퍼 과도특성 해석 (Transient Characteristic Analysis of Damper in Superconducting Synchronous Generator by the Compensated 2D Analysis Model)

  • 전연도;이형우;이주;홍정표;권영길;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권2호
    • /
    • pp.93-101
    • /
    • 2000
  • This paper presents a novel method for the transient of eddy currents in the dampers of a super-conducting synchronous generator(SCG). The method proposes a 2-D corrected model which takes into account the influence of leakage fluxes of the field winding ends by increasing the effective air gap in order to consider the high precision of the analysis for the conventional 2-D model. The electromagnetic fields for the corrected model are analyzed by the time-stepping finite element method, thus the eddy currents in the dampers and electro-motive forces(EMF) in the stator windings are calculated. As the results, it is proved the presented method is comparatively accurate by comparing measured phase EMF values and the simulation ones, where about 6.4% error at the maximum value of EMF is occurred between them.

  • PDF