• Title/Summary/Keyword: substation

Search Result 998, Processing Time 0.034 seconds

Newly Proposed Seismic Criteria of Transmission and Substation Equipments (송변전기기의 내진설계기준 제안)

  • 조양희;박형기;송영철;방기성
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.163-170
    • /
    • 2002
  • A new seismic design criteria of electric transmission and substation facilities has been proposed. For this propose, the historic data of the earthquake damage and the state-of-the-art of the facilities were carefully reviewed and evaluated. Based on the results, a most reasonable and efficient design criteria has been extracted and proposed for the practical design of the facilities. The criteria is expected to be effectively used for obtaining the seismic safety of newly constructed or extensioning facilities. However, an independent criteria is required to evaluate and improve the seismic capacity of existing facilities

  • PDF

The design of the traction power supply for the test line of Light Rail Vehicle (경전철 시험선용 전력공급시스템 설계)

  • 김국진;백병산;전용주;정상기;김남규
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.322-328
    • /
    • 2001
  • In the electric railway systems, it is very important that we should design the system configuration, location and power capacity of substation. This paper presents the results of system configuration and system design of the DC traction power supply for the test line of Light Rail Vehicle. The voltage fluctuation of train and the power capacity of substation are calculated by computer simulation using the nodal equation, K.C.L/K.V.L, Ohm's law and superposition theory.

  • PDF

Substation Power Quality Test of Hanvit 350 running (한국형 고속열차 주행시 전철변전소 전력품질 시험)

  • Lee, Tae-Hyung;Park, Choon-Soo;Im, Young-Chan;Choi, Seong-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1479-1481
    • /
    • 2007
  • It is important to evaluate the power quality at a substation when a test train is running. Especially, the Korea Electric Power Company(KEPCO) restrict the power quality generated from the electrical train within limited value. So, this paper represents the results of the power quality test when Hanvit 350 is running at the KTX high speed line and the assessment.

  • PDF

Grounding System Design of GIS type AC Substation using Personal Computer (P.C.에 의한 GIS형 AC Substation의 접지계 설계)

  • Yim, Han-Suck;Kim, Wang
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-53
    • /
    • 1990
  • GIS(Gas-Insulated Switchgear)형 옥내변전소에 있어서 접지계의 구성은 접지도체를 포설할 수 있는 면적이 협소하기 때문에 특별한 설계방법이 요구된다. 본 논문에서는 접지망의 전위해석과 축소형 변전소의 접지계 설계기법을 제시하였고, 아울러 컴퓨터 시뮬레이션을 위한 프로그램을 작성하고 그 시뮬레이션 결과를 측정치와 비교하여 프로그램의 타당성을 입증하였다.

  • PDF

Analysis on Fault for Switching Devices in Transmission & Substation System (송변전계통 전력개폐설비의 고장 실태조사 연구)

  • Lee, Bong-Hee;Lee, Hie-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.415-417
    • /
    • 1999
  • Recently, Reliability of switching devices for transmission & substation system is very important. Therefore, We have investigated fault trend of switching devices from 1982 to 1998 This paper presents fault analysis on Circuit Breakers, Disconnecting Switch, Gas Insulated Switchgear, etc. Thus, this paper will help improve design, manufacture, construction technology and maintenance method.

  • PDF

A Study on the Criteria of Earthing Systems for Substation (변전소의 접지설계기준에 관한 연구)

  • Kim, I.S.;Kim, M.K.;Huh, D.H.;Yoon, J.Y.;Han, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.152-154
    • /
    • 2007
  • This paper represents the criteria of earthing system for substation design in Korea. The construction of new substations and expansion of existing facilities are commonplace projects in KEPCO(Korea Electric Power Corporation). The KEPCO has had the only design criteria, which need to be adequate criteria considering the new technology and environment in Korea.

  • PDF

A Study on Substation Automation in Power System (전력계통의 변전소 자동화에 대한 연구)

  • Moon, Hyoung-Bae;Lim, Seong-Joo;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.119-124
    • /
    • 2005
  • The deregulation of energy market, together with structure reorganization of vertically integrated companies in electrical utility requires efficient and reliable substation automation system. The problem of non-standards where other countries suffer through the SA points could be settled using IEC 61850 and hereby the coming SAS project can realize the system that characterize the telecommunication standards and function integration.

  • PDF

Interoperability Test of the Digital Substation using IED Conformance Testing System (IED 적합성 시험장치를 이용한 디지털 변전소 상호운용성 시험)

  • Lee, N.H.;Jang, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.11-12
    • /
    • 2007
  • In order to verify a digital substation based on IEC 61850, KEPRI in charge of POWER IT project related to SAS has constructed IED conformance testing system, which consists of HMI, IED (Intelligent Electronic Device), network equipment, V/I generator, and performed the interoperability test between two IEDs made by other vendors. The test was proceeded based on SCL and with system integrated tools

  • PDF

A study of bad data processing application in the substation (변전소내 Bad Data Processing어 관한 연구)

  • Jin B.G.;Choi I.S.;Hyun S.H.;Lee S.J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.406-408
    • /
    • 2004
  • It is very necessary to adopt bad data processing in order to maintain the security and the reliability of data acquisition and management in the substation. This paper presents a bad data processing method of per module unit by using rule based system. The propriety of this method has been verified by the case study

  • PDF