• 제목/요약/키워드: subjective visual assessment

검색결과 102건 처리시간 0.021초

시각자극에 대한 실시간 및 비 실시간 주관적 평가와 생리반응과의 상관관계 (Correlation between Real-Time and Off-Time Subjective Assessments and Physiological Responses for Visual Picture Stimulus)

  • 정순철;민병찬;민병운;김상균;오지영;김유나;김철중;박세진
    • 대한인간공학회지
    • /
    • 제18권3호
    • /
    • pp.27-39
    • /
    • 1999
  • The purpose of this study was to approve the capability of human sensibility evaluation based on physiological responses and real-time subjective assessments. Three well-trained healthy human subjects were participated in the experiments. We measured physiological responses such as Heart Rate Variability(HRV), Galvanic Skin Response(GSR) and skin temperature under rest and visual stimulation conditions, respectively. Off-time subjective assessments were recorded before and after visual stimulations. Real-time subjective assessments were recorded during visual stimulations. The results of physiological responses and off-time and real-time subjective assessments were quantified and compared. The results showed that the correlation between physiological responses and real-time subjective assessments was high (83%) for both the positive and negative visual stimulation. The correlation between the physiological responses and off-time subjective assessments was high (83%) for the negative visual stimulation but was low (15%) for the positive visual stimulation. Although the current observation is preliminary and requires more careful experimental study, it appears that the correlation between real-time subjective assessment and physiological responses is higher than that of the off-time subjective assessment and physiological responses.

  • PDF

실시간 주관적 감성 변화와 GSR 반응과의 상관 관계 (A Study on Correlation between On-Line Subjective Evaluation and GSR)

  • 정순철;민병찬
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2003년도 춘계학술대회 논문집
    • /
    • pp.120-122
    • /
    • 2003
  • In this study, an experiment was conducted in order to investigate the feasibility and effectiveness of and on-line subjective assessment (OLSA) system. The present study compared Galvanic Skin Response (GSR) with the OLSA by presenting 28 subjects in their 20s with pictures arousing either positive or negative sensibility. According to the correlation coefficients, changes in subjective sensibility caused by the positive visual stimulus were related more closely to GSR, from the positive visual stimulus, and changes in subjective sensibility caused by the negative visual stimulus were related more closely to GSR from the negative visual stimulus. In conclusion, the most remarkable characteristic of the present system is that it not only assesses the average sensibility when stimuli are presented, but also shows the changing strength of sensibility over time.

  • PDF

실시간 주관적 감성 평가시스템을 이용한 긍정 및 부정 시각자극에 대한 연구 (A Study on Positive and Negative Visual Stimuli using the Real-Time Human Sensibility Assessment System)

  • 민병찬;정순철;민병운;신미경;정학기;김철중
    • 대한인간공학회지
    • /
    • 제20권1호
    • /
    • pp.31-43
    • /
    • 2001
  • The present study the feasibility of the new subjective assessment devise; Real-Time Subjective Assessment Digitizer (RTSAD). The subjects were instructed to evaluate their sensibility during the presentation of the positive and the negative visual stimuli using RTSAD. After the presentation of each of the stimulus, a questionnaire was used for comparing the results with those from RTSAD. It was argued that the biggest utility of the RTSAD is the capability of measuring and figuring out the trends of the subjective assessment in real time. The results from the questionnaires unlike the results from RTSAD, reflects only the averaged human sensibility for the entire time of the presentation of the stimulus.

  • PDF

Visual Analogue Scale(VAS)을 이용한 동통평가표에 의한 동통관리의 효용성에 관한 연구 (A Study on Efficiency of Pain Management by Questionnaire using Visual Analogue Scale in Back - Pain Patients)

  • 이복희;윤홍일;박지환
    • 대한정형도수물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.105-112
    • /
    • 1995
  • This study was designed to investigate the efficiency of subjective assessment that exams the subjective symptom of patients with back pain at the department of physical therapy. To assess the subjective symptom, we used the pain questionnaire using visual analogue scale (VAS) that was developed by Wang on 1995. Questionnaires were administered to 31 adult patients(male : 11, female : 20) with herniated lumbar disk(13), low back pain(8), myofascial pain syndrom(5), lumbar strain(4), ankylosing spondylitis(1). Mean age was 36.3 ranged from 20 to 65. The results of this study were as follows : 1) In each of 15 subjects, there was a significant decrease in VAS between pre- and post-treatment(p<0.05). 2) Mean VAS of total subjects was $6.26{\pm}2.55$ in pre-treatment, $4.50{\pm}2.47$ in post-treatment (p<0.001). Result of this study was shown efficiency of pain management by subjective assessment. The continuous study is needed for many interesting illue of pain management using VAS.

  • PDF

3D 영상의 제작 왜곡이 시청 피로도에 미치는 영향 분석 (An Analysis of Visual Fatigue Caused From Distortions in 3D Video Production)

  • 장형준;김용구
    • 방송공학회논문지
    • /
    • 제17권1호
    • /
    • pp.1-16
    • /
    • 2012
  • 양안식 입체 영상 미디어의 제작 워크플로우 개선을 위해, 본 논문에서는, 제작 및 후-제작 단계에서 발생할 수 있는 다양한 제작 왜곡들이 시청 피로도에 미치는 영향을 주관적 시청 실험을 통해 분석하였다. 주관적 시청 실험의 객관적 지표 생성을 위해 제작 왜곡의 요인들을 분류하여 7가지의 대표적 시청 피로도 유발 요인을 선정하고, 선정된 각 요인 별 시청 실험을 위해 카메라와 피사체의 움직임 정도를 조합하여 4가지 실험 동영상을 제작하였다. 제작된 실험 영상들은 각기 7단계의 제작 왜곡을 부가하여 5초 단위의 시청 실험 콘텐츠 196개를 생성하였으며, 생성된 콘텐츠와 ITU-R BT.1438 권고에 따라 총 101명의 실험 참가자를 모집하여 주관적 시청 실험을 실시하였다. 실시된 시청 실험의 분석 결과는 제작 현장에서 발생할 수 있는 다양한 왜곡에 대한 상대적인 중요도 및 각 오차에 대한 허용 한계 범위 등에 대한 기본 정보를 제공한다.

VAS를 이용한 동통평가표에 의한 동통관리의 효용성에 관한 연구 (A Study on Efficiency of Pain Management by Questionnaire using Visual Analogue Scale in Back- Pain Patients)

  • 이복희;윤홍일;박지환
    • 대한물리치료과학회지
    • /
    • 제2권3호
    • /
    • pp.679-689
    • /
    • 1995
  • This study was designed to investigate the efficiency of subjective assessment that exams the subjective symptom of patients with back pain at the department of physical therapy. To assess the subjective symptom, we used the pain questionnaire using visual analogue scale(VAS) that was developed by Wang on 1995. Questionnaires were administered to 31 adult patients(male : 11, female: 20) with herniated lumbar disk(13), low back pain(8), myofascial pain syndrom(5), lumbar strain(4), ankylosing spondylitis(1). Mean age was 36.3 ranged from 28 to 65. The results of this study were as follows: 1) In each of 15 subjects, there was a significant decrease in VAS between pre-and post-treatment(p < 0.05 -p<0.001). 2) Mean VAS of total subjects was $6.26{\pm}2.55$ in pre-treatment, $4.50{\pm}2.47$ in post-treatment(p < 0.001). The result of this study was shown efficiency of pain management by subjective assessment. The continuous study is needed for many interesting issue of pain management using VAS.

  • PDF

An Objective No-Reference Perceptual Quality Assessment Metric based on Temporal Complexity and Disparity for Stereoscopic Video

  • Ha, Kwangsung;Bae, Sung-Ho;Kim, Munchurl
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제2권5호
    • /
    • pp.255-265
    • /
    • 2013
  • 3DTV is expected to be a promising next-generation broadcasting service. On the other hand, the visual discomfort/fatigue problems caused by viewing 3D videos have become an important issue. This paper proposes a perceptual quality assessment metric for a stereoscopic video (SV-PQAM). To model the SV-PQAM, this paper presents the following features: temporal variance, disparity variation in intra-frames, disparity variation in inter-frames and disparity distribution of frame boundary areas, which affect the human perception of depth and visual discomfort for stereoscopic views. The four features were combined into the SV-PQAM, which then becomes a no-reference stereoscopic video quality perception model, as an objective quality assessment metric. The proposed SV-PQAM does not require a depth map but instead uses the disparity information by a simple estimation. The model parameters were estimated based on linear regression from the mean score opinion values obtained from the subjective perception quality assessments. The experimental results showed that the proposed SV-PQAM exhibits high consistency with subjective perception quality assessment results in terms of the Pearson correlation coefficient value of 0.808, and the prediction performance exhibited good consistency with a zero outlier ratio value.

  • PDF

블록기반 동영상 부호화기의 객관적 화질평가 (Objective Picture Quality Assessment of Block Based Moving Picture Coder)

  • 정태윤;홍민석;박강서;김현술;박상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1589-1598
    • /
    • 1999
  • Conventional MSE or PSNR based methods for objective picture quality assessment of moving picture coder are not well correlated with subjective human evaluation. In recent years, the design of better objective quality assessment has attracted much intention and several picture quality metrics based on the properties of Human Visual System has been proposed. This paper proposes new metric which is appropriate for objective picture quality assessment of block based moving picture coder by considering frequency sensitivity, inter-intra channel masking and several distortion artifacts caused by block based coding. The experimental results show that the proposed method is good correlated with subjective assessment.

  • PDF

철도영상전송시스템의 화질평가방안에 관한 연구 (A study on the Quality Assessment Method on Railway Video Transmission System)

  • 장석각;조봉관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1247-1252
    • /
    • 2004
  • A objective quality assessment for the evaluation performance of a video transmission system as a basic step for construction of digital video transmission system between the spots and headquarter. Due to a limit of an analog video transmission system and the developments of various digital media and digital video standards, the need of introduce of a digital system are increased gradual1y, At this points. previously performance evaluations are performed and the quality assessment is the most important thing. We can be divided quality assessment method by the subjective quality assessment and objective quality assessment. The subjective quality assessment method has some problems which are required high cost and much time to evaluate the quality, And because existing objective quality assessment method such that PSNR are based on an analog form, the correlation with subjective data is very low. Therefore we design a new objective quality assessment method using Gabor wavelet transform reflecting HVS(Human Visual System), Designed objective quality assessment method is superior to other objective method such that PSNR or EPSNR In this paper, we proposed objective quality assessment using Gabor wavelet can be used for performance evaluation and verification of video transmission system.

  • PDF

An Image Quality Assessment Scheme based on HVS using Gabor Function

  • Eom Minyoung;Choe Yoonsik
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.128-132
    • /
    • 2004
  • In this paper, we propose a new image quality assessment scheme considering the human visual perception characteristics. A subjective quality assessment is obtained by the response of the receptive field in the primary visual cortex and a human's eye can't focus on all of the visual range in a moment. Take advantage of two facts above, we apply Gabor wavelet transform, which is well fit the receptive field in the cortex, to divided constant sized subblocks. Then a local distortion of the subblocks and a global distortion for the entire image are calculated in order. The proposed method has been evaluated using video test sequences provided by the Video Quality Experts Group (VQEG). The experimental results show that good correlation with human perception is obtained using the proposed metric, which is what we called GPSNR.

  • PDF