• 제목/요약/키워드: subcutaneous fat thickness

검색결과 77건 처리시간 0.038초

초음파법에 의한 피하지방두께의 측정과 신체조성 (Body composition and measurement of subcutaneous fat thickness by ultrasonic method)

  • 성수광;장수정
    • 대한인간공학회지
    • /
    • 제13권1호
    • /
    • pp.47-58
    • /
    • 1994
  • The purpose of this study was to obtain the basic data for a design for comfort wear. The subjects of this study were 197 women's university stu- dents. The characteristics of their body types and the thickness of subcuta- neous fat at eight body sites were measured. The thickness of subcutaneous fat was measured by both Ultrasonics and with a Skinfold Caliper. The cor- relation between their values and the thickness of subcutaneous fat were compared. The relationship between Rohrer Index and the subject's self- conception of their body was also compared. The results were as follows: 1. The measurement of thickness of subcutaneous fat at triceps and scapula was a little lower, in using Skinfold Caliper method, than Ultrasonics method because of the pressure of the caliper. 2. Correlation between percentage of fat in body and body characteristics was high in order of chest girth > weight > abdomen girth. 3. The thickness of subcutaneous 8 body these sites was high in order of thigh > triceps > scapula > abdomen > suprailiac > chest > calf > forearm. Percentage of body fat has a positive correlation with both average thickness of subcutaneous fat and thickness of subcutaneous fat at triceps. 4. Rohrer Index shows a positive correlation between average thickness of subcutaneous fat and percentage of body fat. 5. About half of subjects of this study thought that they were obese although the data proved otherwise.

  • PDF

피하지방두께와 착의량에 관한 연구 -대학생을 중심으로- (A Study on the Subcutaneous Fat Thickness and Clothing Weight)

  • 정운선;최정화
    • 한국의류학회지
    • /
    • 제8권3호
    • /
    • pp.73-79
    • /
    • 1984
  • The purpose of the study is to obtain the basic data of the proper clothing weight according to the subcutaneous fat thickness. This study was done in April and October, and the subjects were 295 male and female college students. Results were as follows: 1. In the case of female students in April, there was no correlation between the subcutaneous fat thickness and the total clothing weight. But there was low negative correlation between the subcutaneous fat thickness and the upper and under clothing weight. 2. In the case of female students in October, there was low negative correlation between the subcutaneous fat thickness and the total, upper, outer clothing weight. 3. In the case of male students in October, there was no correlation between the subcutaneous fat thickness ana the clothing weight.

  • PDF

Abdominal Subcutaneous Fat Thickness Measured by Ultrasonography Correlates with Hyperlipidemia and Steatohepatitis in Obese Children

  • Lee, Sung Hyun;Kim, Dongwan;Baek, Min Young;Tchah, Hann;Kim, Yeon Sun;Ryoo, Eell;Kim, Yun Mi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제18권2호
    • /
    • pp.108-114
    • /
    • 2015
  • Purpose: The aim of this study is to evaluate the relationship between abdominal subcutaneous fat thickness measured by ultrasonography (US) and serum lipid profile and liver transaminases in obese children. Methods: One hundred and sixty-six children diagnosed with obesity from May 2001 to December 2013 were included in this study. Data on serum lipid profile and liver transaminases were collected from clinical records. Abdominal subcutaneous fat thickness and grade of hepatic steatosis were evaluated by US. Results: Of the 166 children, 107 were diagnosed with hepatic steatosis by US, 46 with grade I, 56 with grade II, and five children with grade III. According to the grade of hepatic steasosis, the average values of midline abdominal subcutaneous fat thickness and right flank abdominal subcutaneous fat thickness measured $2.9{\pm}0.8cm$ and $1.9{\pm}0.7cm$ in the normal group, $3.3{\pm}0.8cm$ and $2.0{\pm}0.7cm$ in grade I, $3.8{\pm}0.8cm$ and $2.3{\pm}0.8cm$ in grade II, and $4.1{\pm}0.8cm$ and $2.8{\pm}1.4cm$ in grade III, respectively. Abdominal subcutaneous fat thickness correlated with grade of hepatic steatosis (p<0.01). In addition, abdominal subcutaneous fat thickness correlated with concentration of serum lipids and liver transaminases in the age group of 12-14 years (p<0.01). Conclusion: Abdominal subcutaneous fat thickness measured by US can be used as a reliable predictor of possible hyperlipidemia and steatohepatitis in children, especially during the adolescent stage.

Thickness of Rectus Abdominis Muscle and Abdominal Subcutaneous Fat Tissue in Adult Women: Correlation with Age, Pregnancy, Laparotomy, and Body Mass Index

  • Kim, Jungmin;Lim, Hyoseob;Lee, Se Il;Kim, Yu Jin
    • Archives of Plastic Surgery
    • /
    • 제39권5호
    • /
    • pp.528-533
    • /
    • 2012
  • Background Rectus abdominis muscle and abdominal subcutaneous fat tissue are useful for reconstruction of the chest wall, and abdominal, vaginal, and perianal defects. Thus, preoperative evaluation of rectus abdominis muscle and abdominal subcutaneous fat tissue is important. This is a retrospective study that measured the thickness of rectus abdominis muscle and abdominal subcutaneous fat tissue using computed tomography (CT) and analyzed the correlation with the patients' age, gestational history, history of laparotomy, and body mass index (BMI). Methods A total of 545 adult women were studied. Rectus abdominis muscle and abdominal subcutaneous fat thicknesses were measured with abdominopelvic CT. The results were analyzed to determine if the thickness of the rectus abdominis muscle or subcutaneous fat tissue was significantly correlated with age, number of pregnancies, history of laparotomy, and BMI. Results Rectus abdominis muscle thicknesses were 9.58 mm (right) and 9.73 mm (left) at the xiphoid level and 10.26 mm (right) and 10.26 mm (left) at the umbilicus level. Subcutaneous fat thicknesses were 24.31 mm (right) and 23.39 mm (left). Rectus abdominismuscle thickness decreased with age and pregnancy. History of laparotomy had a significant negative correlation with rectus abdominis muscle thickness at the xiphoid level. Abdominal subcutaneous fat thickness had no correlation with age, number of pregnancies, or history of laparotomy. Conclusions Age, gestational history, and history of laparotomy influenced rectus abdominis muscle thickness but did not influence abdominal subcutaneous fat thickness. These results are clinically valuable for planning a rectus abdominis muscle flap and safe elevation of muscle flap.

향한기의 표의훈련이 피하지방두께에 미치는 영향 (Effect on the Subcutaneous Fat Thickness of the clothing Training in the Cold Condition)

  • 박승순;이원자
    • 한국의류학회지
    • /
    • 제23권4호
    • /
    • pp.551-562
    • /
    • 1999
  • This study was intended to investigate the effect on the human body such as subcutaneous fat thickness the circumference of extremities etc. of the clothing training of putting on thin clothes periodically from the cold period. The subjects were divided into the clothing training group and the non-training group, The training group was asked to wear cool clothes in daily life and to wear the training clothes of T-shirts with half-length sleeves and pants and perform the clothing training for two hours daily three times a week in a cold environment over the period from November to February. The non-training group was asked to lead a life wearing comfortable clothes. Then a comparative experiment was conducted at 15$\pm$1$^{\circ}C$, 50$\pm$5% R, H and 0.25m/sec before and after the clothing training. After the clothing training regardless of gender subcutaneous fat thickness was more increased and total clothing weight per the surface area of the body was decreased in the training group than the non-training group. The training group showed lower skin temperature in the limbs and lower average skin temperature than the non-training group irrespective of gender which proved the effect of the clothing training. The training group was shown to have attendancy toward a greater sense of warmth and a less sense of discomfort which proved the effect of the clothing training.

  • PDF

체지방량 추정을 위한 초음파피지후계와 Caliper의 비교 (Comparison of Caliper and Ultrasound Measurement for the Estimation of Body Fat)

  • 정진욱
    • Journal of Nutrition and Health
    • /
    • 제28권4호
    • /
    • pp.282-290
    • /
    • 1995
  • Subcutaneous fat thickness of 74 young male was measured at six sites(biceps, triceps, subscapula, suprailiac, abdomen, thigh). The present study compared caliper with ultrasound measurements for the estimation of body fat. Caliper measurements subcutaneous at six sites had higher coefficient variation than did the ultrasound measures. Caliper measurements subcutaneous at six sites had higher ratio (caliper/ultrasound) than did the ultrasound measures. Compared to other body sites, the correlations between caliper and ultrasound measurements were high for the subscapula(r=0.7327), abdomen(r=0.7355) and thigh (r=0.7207) sites. the correlations between caliper and ultrasound measurements were high for the suprailiac(r=0.6616) site by lean group. the correlations between caliper and ultrasound measurements were high for the abdomen(r=0.7636) site by normal group. The correlations between caliper and ultrasound measurements were high for the subscapula (r=0.8959) and abdomen(r=0.8237) sites by obese group. Ultrasound measurement of biceps(r=-0.4459), abdomen9r=-0.4469), thigh(r=-0.4348) had the highest correlation with body density. Caliper measurement of triceps(r=-0.4017), subscapula(r=-0.4454), abdomen(r=-0.4293) had the highest correlation with body density. Ultasound measurements subcutaneous fat at lean group, obese group had higher coefficients of correlation with body density than did the caliper measurement. Caliper measurements subcutaneous fat at normal group had higher coefficients of correlation with body density than did the ultrasound measures. Ultrasound showed to be superior to the caliper technique in measuring subcutaneous fat of obese persons.

  • PDF

신체 부위에 따른 지방조직의 특성: 컴퓨터단층촬영 및 조직학적 소견 (Characteristics of Fat Tissue According to the Anatomical Regions of the Body: Computed Tomographic and Histological Findings)

  • 신동우;손대구;박무식;김준형;한기환
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.535-546
    • /
    • 2010
  • Purpose: The subcutaneous fat tissue is separated into 2 layers by the subcutaneous fascia: the superficial and deep fat layers. The two fat layers have different structures according to the body regions. The purpose of this study is to evaluate the distribution and pattern of the two fat layers in the human body by computed tomography (CT) and histological analysis according to age, sex, anatomical region, and body mass index (BMI). Methods: This study included 200 males and 200 females who underwent 64-channel dynamic CT in our hospital. The patients were divided into 5 groups according to 10 years of their ages separately in either male or female gender. The thickness of the superficial and deep fat layers was measured in the abdominal, pelvic, and femoral regions, and we analyzed the values. Statistical analyses were performed using SPSS software. The $3{\times}3$-cm whole fat layers were harvested from the same sites of 3 cadavers for histological examination, and one cadaver was dissected for gross evaluation. Results: The total thickness of subcutaneous fat tissue was greater in females than in males, and the ratio of the superficial fat layer to the whole fat layer was higher in females. The superficial fat layer became thinner with increasing age in males. As BMI increased, the total fat layer became thicker, and the superficial fat layer became thicker than the deep fat layer. On histological examination, the superficial fat layer had small adipose lobules and showed a densely distributed pattern in the abdominal region, whereas in the femoral region, it had large adipose lobules and showed a sparsely distributed pattern. There were no significant differences in the histological findings of the deep fat layer between the 3 body regions. Conclusion: Significant differences in histological findings of the two fat layers were found in relation to age, sex, anatomical region, and BMI. The superficial fat layer became thinner with increasing age in males, but it was constant in females. As BMI increased, the total thickness of subcutaneous fat tissue became greater, and the superficial fat layer became thicker than the deep fat layer. Our measurements can be used to understand the characteristics of the fat layers in relation to age, sex, anatomical region, and BMI.

Abdominal skin subcutaneous fat thickness over the gestational period in Korean pregnant women: a descriptive observational study

  • Hwang, Moon Sook
    • 여성건강간호학회지
    • /
    • 제27권4호
    • /
    • pp.318-325
    • /
    • 2021
  • Purpose: Although insulin is usually injected into the abdominal subcutaneous fat, in pregnancy women tend to avoid abdominal injections due to concern about fetal damage. Prior studies have been limited to only measuring skin-subcutaneous fat thickness (S-ScFT) at one site at specific pregnancy points. This study aimed to measure S-ScFT across several abdominal sites and over the gestational period in Korean pregnant women. This can identify which site would be relatively safe for subcutaneous injection during pregnancy. Methods: Healthy women over 24 weeks of pregnancy in Korea were invited to voluntarily participate in this descriptive study. For the 142 women, S-ScFT of 12 sites in the abdomen were measured by ultrasound, several times over the pregnancy. Each incidence was treated as a case and a total of 262 cases were analyzed. Results: The mean S-ScFT during pregnancy was 1.14±0.47 cm (1.25±0.54 cm at 24+0-27+6 weeks; 1.17±0.48 cm at 28+0-31+6 weeks; 1.09+0.40 cm at 32+0-35+6 weeks; and 1.06±0.47 cm at 36+0-40 weeks of pregnancy). Most S-ScFT were thicker than 10 mm. But S-ScFTs in the lateral abdomen and some sites were suboptimal (<6 mm), especially in the pre-pregnancy underweight body mass index group, who had a high rate of suboptimal thickness (27.1% overall and 33.9% in the lateral side). Conclusion: The whole abdomen seems to be appropriate for subcutaneous injection in most Korean women during pregnancy, with a 4 to 5-mm short needle. However, for the lateral abdomen, making the skin fold might be needed for fetal safety.

전기와 자기장 복합 침 자극을 활용한 복부비만 치료 6례에 대한 증례 보고 (A Report on 6 cases of Abdominal Obesity using Electroacupuncture Combined with Magnetic Acupuncture)

  • 윤지원;이현;김윤주;강재희
    • Journal of Acupuncture Research
    • /
    • 제32권4호
    • /
    • pp.213-226
    • /
    • 2015
  • Objectives : This study was aimed to show the effect of electroacupuncture combined with magnetic acupuncture on abdominal obesity without patient dieting, exercise or use of herbal medication. Methods : Women over 85 cm in waist circumference were treated with electroacupuncture combined with magnetic acupuncture. Acupuncture points were located at the abdomen ($CV_{12}$, $CV_6$, $ST_{25}$, $ST_{21}$, $SP_{15}$, $SP_{14}$), extremities ($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) and were stimulated 30 minutes with 2.1~3 Gaus, 500 Hz, tolerable strength. The Interference wave forms were by Whata 153 (Medi Lab, Korea). Two or three treatment sessions per week (five or ten sessions in total) were done. Before treatment, and after the last treatment, we measured waist circumference, hip circumference, waist hip ratio, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio, visceral fat area, free fat mass, body fat mass and skeletal muscle mass. We also measured the subcutaneous temperature of the abdomen($CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$, $CV_6$) by using digital infrared thermal imaging(DITI). Results : In this study, significant reductions were shown in waist circumference, hip circumference, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio and body fat mass. There were no significant differences in waist hip ratio, free fat mass or skeletal muscle mass. There were also significant increases of the subcutaneous temperature on $CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$. Conclusions : From the above results, electroacupuncture combined with magnetic acupuncture might be an effective treatment for abdominal obesity.

전기근육자극 훈련이 복부비만 중년 여성의 복부지방, 체간 근 두께와 활성도에 미치는 영향 (Effects of Neuromuscular Electrical Stimulation Training on Abdominal Fat, Trunk Muscle Thickness and Activity in Middle-Aged Women with Abdominal Obesity)

  • 유승아;유기웅;임창하;김창용;김형동
    • 대한물리의학회지
    • /
    • 제14권2호
    • /
    • pp.125-135
    • /
    • 2019
  • PURPOSE: This study examined the effects of low frequency neuromuscular electrical stimulation (NMES) training on abdominal obesity in middle-aged women through electromyography and ultrasound. METHODS: Twenty-two middle aged women with abdominal obesity participated in the study. A low-frequency NMES device was used on the abdomen and waist of each subject for 20 minutes each (a total of 40 minutes) three times a week for eight weeks. The waist-hip ratio (WHR), weight and BMI (Body Mass Index) were measured. Electromyography (EMG) and ultrasound measurements were performed three times in total (pre-intervention, four weeks into the intervention, and eight weeks post-intervention) to examine the effects of low-frequency NMES on the abdominal muscle activity, muscle thickness, and subcutaneous fat. RESULTS: The results indicated a difference in the WHR and waist circumference before and after intervention (p<.05). The external oblique muscle (EO) showed a significant increase in muscle activity during all measurements taken post-intervention (p<.05). The abdominal subcutaneous fat thickness also showed a significant decrease between each measurement (p<.05). The test results showed that the abdominal subcutaneous fat thickness values taken eight weeks post-intervention were significantly lower than those taken pre-intervention and four weeks into the intervention (p<.05). CONCLUSION: These findings show that low-frequency NMES device training can be applied to middle-aged women with abdominal obesity to improve their body shape and exercise performance.