• 제목/요약/키워드: subcooling temperature

검색결과 135건 처리시간 0.025초

저온축열용 포접화합물에 냉각특성에 관한 실험적 연구 (A study on cooling characteristics of clathrate compound for cold storage applications)

  • 한영옥;김진흥
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

저온축열용 포접화합물의 열물성에 관한 실험적 연구 (An Experimental Study on Thermal Properties of Clathrate for Cold Storage Applications)

  • 한영옥;정낙규;김진흥
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.725-734
    • /
    • 2000
  • The objective of this paper is to investigate the thermal properties of TMA clathrate applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are peformed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of concentrations and temperature of heat source in TMA clathrate. The results are summarized as follows; 1) temperature of phase change is dropped as the temperature of heat source is lower, 2) the effect of subcooling suppression with about $9.3^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 29wt% and 30wt% . Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$ Thus, it is concluded that TMA clathrate has proper properties as the cold storage medium for building air-conditioning.

  • PDF

Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구 (A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology)

  • 곽경민;배철호
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.

냉매 과냉각을 이용한 열펌프 시스템의 성능 특성 (The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

빙축열시스템 PCM용 TMA-포접화합물의 과냉도 개선에 대한 연구 (The Study on Improvement in Subcooling of TMA Clathrate for PCM in Ice Storage System)

  • 김진흥;정낙규;김창오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1663-1666
    • /
    • 2003
  • TMA clathrate that is used by PCM of ice storage system in this research creates hydrate crystallization at higher temperature than pure water, and application is expected as PCM because having comparative big dormant temperature without phase separation phenomenon. In case this research uses TMA clathrate by PCM, choose admixture by purpose to control or remove subcooling of TMA clathrate and evaluated experimentally. Subcooling is improved and can expect contraction of freezing machine running time and increase of coefficient of performance as that add admixture to TMA clathrate conclusively. Also, may supply thermal storage system that apply low temperature potential heat thermal storage material that subcooling is improved more extensively laying stress on medium size building and small size building, can expect allowance through localization of ice storage system.

  • PDF

첨가제를 포함한 TMA포접화합물의 열물성에 관한 기초적 연구 (A Basic Study on Thermal Properties of TMA Clathrate with Additives)

  • 고광옥;정낙규;김진홍
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1097-1105
    • /
    • 2001
  • The purpose of this study is to investigate the propriety of TMA clathrate as a cold storage medium. Particularly, this is to examine the extent of subcooling improvement when the additives are added to the TMA clathrate, because water used cold storage material has low phase change temperature and subcooling. This study has been analysed and compared with TMA 30 wt% clathrate how phase change temperature, subcooling and specific heat in the various concentrations are changed. This results view to be improved phase change temperature and subcooling of TMA 30 wt% as a cold storage medium, when it had some additive. Additional1y, it is found that the additive must be controlled under available solution limit and study for new additive must be lasted to know its effect.

  • PDF

액 수위와 유량이 세장비가 큰 냉동용 수직 리시버의 과냉에 미치는 영향 (Effect of Liquid Level and Mass Flow Rate on Subcooling of Vertical Refrigeration Receiver Having a Large Aspect Ratio)

  • 김내현
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.385-389
    • /
    • 2017
  • Generally, refrigerant temperature out of the receiver is assumed to be saturated. This may be true for horizontal or vertical receivers having small aspect ratio. However, this assumption needs verification for vertical receiver having large aspect ratio. No study has reported information on this issue. The objective of this study was to determine the effect of liquid level and mass flow rate on liquid subcooling of a long vertical receiver using R-410A. During the test, inlet subcooling was maintained at $5^{\circ}C$ while saturation temperature was maintained at $10^{\circ}C$. Results showed that subcooling was maintained for the long vertical receiver. Subcooling preservation ratio (ratio of exit to inlet subcooling) was increased as mass flow rate or liquid level was increased. As a whole, 50 to 70% subcooling preservation was possible for the present receiver. Further investigations are needed to enhance information on this issue using receivers having different aspect ratios.

TMA-물계 포접화합물의 냉각특성과 과냉각 개선에 대한 연구 (A Study on the Cooling Characteristics and Subcooling Improvement of TMA-Water Clathrate Compound)

  • 박설현;김창오
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.85-92
    • /
    • 2014
  • This study carried out experimental on the cooling characteristics of clathrate compound including TMA(Tri-Methyl-Amine ; $(CH_3)_3N$) as a low temperature latent heat storage material. And additive was used for subcooling improvement of TMA-water clathrate compound. The conclusion of above study is as following ; TMA 25wt%-water clathrate compound is shown stable phase change and low subcooling degree. The subcooling was improved in the case ethanol($CH_3CH_2OH$) 0.5wt% is added to TMA 25wt%-water clathrate compound.

에탄올을 첨가한 TMA 포접화합물의 냉각특성에 대한 연구 (The Study on Cooling Characterics of TMA Clathrate with Ethanol)

  • 김창오;김진흥;정낙규;김석현
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.634-640
    • /
    • 2002
  • The purpose of this study is to investigate the propriety of TMA clathrate as a cold storage medium. Particularly, this is to examine the extent of subcooling improvement when the additives is added to the TMA clathrate, because water used for cold storage ma terial has low phase change temperature and subcooling. This study has been analyzed and compared pure water with TMA 30 wt% clathrate how phase change temperature, subcooling and specific heat in the various concentrations are changed. This results prove low phase change temperature and subcooling control effect when the ethanol is added to the TMA 30 wt% clathrate than the TMA 30 wt% clathrate. In addition, it results low specific heat when there is added to the TMA 30 wt% clathrate over 0.5 wt% ethanol in the cold heat source temperature under $-7^{\circ}C$. The other side, it results high specific heat when the ethanol is added in it at the cold heat source temperature under $-5^{\circ}C$. Therefore, it is found that the additive must be controlled by available solution limit and study for new additive must be lasted to know its effect.

친환경 프레온 냉매를 이용하는 단압축 단팽창 냉동시스템의 성능예측 (Performance Analysis of Two-stage Compression and Two-stage Expansion Refrigeration System using Freon Refrigerants)

  • 노건상;김종열
    • 수산해양교육연구
    • /
    • 제25권2호
    • /
    • pp.301-306
    • /
    • 2013
  • In this paper, cycle performance analysis of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants is presented to offer the basic design data for the operating parameters of the system. Alternative freon refrigerant for freon refrigerant R22 were used as working fluids in this study. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, and mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of two-stage compression and two-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ratio of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and two-stage expansion refrigeration system using alternative freon refrigerants have an effect on COP of this system.