• 제목/요약/키워드: subcooling

검색결과 220건 처리시간 0.023초

비등을 수반하는 발열면에 충돌하는 수분류의 임계열유속에 관한 연구 (Critical Heat Flux of an Impinging Water Jet on a Heated Surface with Boiling)

  • 이종수;김희동;최국광
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.485-494
    • /
    • 2000
  • The purpose of this paper is to investigate a critical heat flux(CHF) during forced convective subcooled and saturated boiling in free water jet system impinged on a rectangular heated surface. The surface is supplied with subcooled or saturated water through a rectangular jet. Experimental parameters studied are a width of heated surface, a height of supplementary water and a degree of subcooling. Incipient boiling point is observed in the temperature of 6${\~}8^{\circ}C$ of superheat of test specimen. CHF depends on jet velocity for various boiling-involved coolant system. CHF also is proportional to the nozzle exit velocity to the power of n, where n is 0.55 and 0.8 for subcooled and saturated boiling, respectively. CHF is enhanced with a higher jet velocity, higher degree of subcooling and smaller width of a heated surface.

첨가제를 첨가한 TMA 물계-포접화합물의 열물성 연구 (The Study of Thermal Properties of TMA Clathrate on Additives)

  • 김광일;정낙규;김진흥;김창오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.250-255
    • /
    • 2003
  • TMA clathrate that is used as PCM of low temperature thermal storage system in this research creates hydrate crystallization at higher temperature then pure water, and its application is expected as PCM because of comparatively big latent heat without phase separation phenomenon. Acetone, Ethylen Glycol, and Ethanol is used as additive and evaluated experimentally for the purpose of the improvement in subcooling of TMA clathrate. In view of the results so far achieved subcooling is improved, the running time of the refrigerator is reduced. Thus the results are expected to use for the increase of coefficient of performance of low temperature thermal storage system in the building.

  • PDF

FLUENT 5.4 코드를 이용한 양방향 유동 튜브에 대한 유동해석 (Flow Analyses using FLUENT 5.4 Code for the Bi-directional Flow Tube)

  • 강경호;윤병조;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.934-938
    • /
    • 2003
  • Flow analyses using FLUENT 5.4 code were performed to validate the application of the local bidirectional flow tube in case of water and air flow. In this study, sensitivity studies have been performed to optimize the design features of the bi-directional flow tube which can be applied for the various experimental conditions. 2-dimensional axisymmetric steady state flow analyses have been performed. By calculating the differential pressure at both the front and the rear hole of the flow tube, K values were evaluated. The K values show good linearity regardless of the tube sizes and the Re numbers in both water and air flow. And system pressure and water subcooling didn’'t affect the K values. Under the elevated pressure of 80bar with 80K water subcooling, the K value indicates a similar trend with the case of 2bar with 80K water subcooling.

  • PDF

자동차용 IRDS 응축기에 대한 실험과 해석적 연구 (An Experimental and Numerical Study on Automotive IRDS Condenser)

  • 김학준
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.58-65
    • /
    • 2011
  • The specific objective of this study was to develop an IRDS (integrated receiver drier subcooling) condenser model for use in a mobile air-conditioning system. A three-zone model based on the desuperheating, two-phase, and subcooling sections of a condenser could be used to estimate the performance with a good accuracy. Overall heat transfer coefficients for each of the three sections, expressed as a function of the air velocity across the condenser and refrigerant mass flow rate and the model using the elemental difference method incorporate calculations to determine the pressure drop, heat performance within the condenser and it includes physical parameters (pass, tube hole size and length) that can be varied to analyze potential design changes without exhaustive experimental efforts. it was found that an accuracy of heat performance was within 5% in case of using the various condensers, the refrigerant pressure drop was predicted within 25% and the pressure drop of air side was well matched with experiment data within 4%.

충돌수분류(衝突水噴流)에 의한 서브쿨 Burnout열류속(熱流束)에 관한 연구 (Subcooled Burnout Heat Flux on a Heated Surface with Impinging Water Jet)

  • 엄기찬;이종수;박성연
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.527-536
    • /
    • 1996
  • Convective nucleate boiling and burnout heat flux have been studied on a flat, downward facing, constant heat flux surface cooled by an impinging water jet. The tests are progressed from low, nonboiling power to high, burnout heat flux power. The jet velocity and the subcooling do not affect the nucleate boiling curve of $q{\sim}{\Delta}T_{sat}$ diagram, but the supplementary water height affects the curve. For the case of dimensionless height of supplementary water S/D=1, the boiling curve shift to the heigher heat flux than that of S/D=0 or S/D=2. Burnout heat flux is enhanced with increasing jet velocity and subcooling. Also. by using the supplementary water(S/D=1 or S/D=2), burnout heat flux is larger than that of the simple water jet(S/D=0). A generalized correlation for the burnout heat flux data in the present boiling system with an impinging water jet is successfully evolved.

  • PDF

FLOW BOILING HEAT TRANSFER FROM PLAIN AND MICROPOROUS COATED SURFACES IN SUBCOOLED FC-72

  • ;;유승문
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.181-188
    • /
    • 2001
  • The present research is an experimental study of subcooled flow boiling behavior using flat, microporousenhanced square heater surfaces in pure FC-72. Two $1-cm^{2}$ copper surfaces, one highly polished (plain) and one microporous coated, were flush-mounted into a 12.7 mm square, horizontal flow channel. Testing was performed for fluid velocities ranging from 0.5 to 4 m/s (Reynolds numbers from 18,700 to 174,500) and pure subcooling levels from 4 to 20 K. Results showed both surfaces' nucleate flow boiling curves collapsed to one line showing insensitivity to fluid velocity and subcooling. The log-log slope of the microporous surface nucleate boiling curves was lower than the plain surface due to the conductive thermal resistance of the microporous coating layer. Both, increased fluid velocity and subcooling, increase the CHF values for both surfaces, however, the already enhanced boiling characteristics of the microporous coating appear dominant and require higher fluid velocities to provide additional enhancement of CHF to the microporous surface.

  • PDF

고온측 냉매에 따른 이원 냉동시스템의 성능 분석 (Performance Analysis of Cascade Refrigeration System with Respect to Refrigerants Appling to High Temperature Cycle)

  • 윤정인;전민주;손창효
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents the Coefficient of performance(COP) and mass flow ratio of cascade refrigeration system with respect to refrigerants appling to high temperature cycle. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporating temperature, condensing temperature and internal heat exchanger effectiveness in high temperature cycle. The result of this study is as follows : The COP of cascade system increases with increasing degree of superheating and subcooling, compressor efficiency and internal heat exchanger effectiveness except increasing condensing temperature. The mass flow ratio of low and high temperature cycle increases with increasing evaporating temperature and condensing temperature, but decreases with increasing internal heat exchanger effectiveness, degree of superheating and subcooling. Also, the mass flow ratio has no correlation with compressor efficiency at high temperature cycle.

R32를 포함한 R22 대체 혼합냉매의 모세관 유동 특성 (Flow Characteristics of Refrigerant Mixtures with R32 in a Capillary Tube)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.177-186
    • /
    • 1996
  • The characteristics of the flow of pure HFC refrigerants(R32, R125, and R134a) and their mixtures through capillary tubes were investigated experimentally. Two capillary tubes with 1.2mm and 1.6mm inner diameter and 1.5m length were adopted as test sections. Mass flow rates and temperatures and pressures were measured for several condensing temperatures and degrees of subcooling at capillary tube inlet. The effects of the condensing temperature, inner diameter of capillary tube, and subcooling on the mass flow rate of refrigerants were discussed, and the mass flow rates of HFC refrigerants were compared with that of R22. The pressure and temperature distributions along the capillary tube compared with that of R22. The pressure and temperature distributions along the capillary tube show that there is a metastable equilibrium state in the flow through the tube. Underpressure for vaporization increases as refrigerant mass flux increases and inlet subcooling decreases. Empirical correlation was suggested to predict underpressure for vaporization of the HFC refrigerants.

  • PDF

상변화 물질을 사용한 축열조에서의 열전달 - 수직원관에서의 내향용융 실험 - (Heat Transfer in Heat Storage System with P.C.M. - Inward Melting in a Vertical Tube)

  • 손화승;황태인;이채문;최국광;임장순
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.53-61
    • /
    • 1989
  • In the present investigation, experiments on the melting of a phase change material were performed to research heat transfer phenomena generated by means of conduction and natural convection in the vertical tube at inward melting. The phase change material used in the experiments is 99 percent pure n-Docosane paraffin which is measured melting temperature of $42.5^{\circ}C$, latent heat of 37.5 cal/g, heat conductivity of $0.1505W/m^{\circ}C$. Experiments were performed both in the no-subcooling which is initiating it at melting temperature of phase change material, and in the subcooling which means to initiate it under melting temperature of phase change material, in order to compare and investigate the horizontal temperature history, vertical temperature history, ratio of melting and melted mass, figure of the melting front in the vertical tube. In the experimental results, heat transfer from tube wall to phase change material were due to conduction at early stage and due to natural convection with the passage of time, and then occurred melting downward from surface by volumetric expansion. Natural convection affects temperature distribution in the tube, ratio of melting and melted mass, figure of the melting front and then progress rapidly in case of nosubcooling compared to subcooling.

  • PDF

초음파 진동이 경사진 평판에서의 CHF에 미치는 영향에 대한 실험연구 (Experimental Study of the Ultrasonic Vibration Effects on CHF Occurring on Inclined Flat Surfaces)

  • 정지환;김대훈;권영철
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.139-144
    • /
    • 2003
  • 본 연구는 초음파 진동의 영향을 받는 풀비등 조건에서의 CHF 열전달 촉진현상을 이해하기 위해 수행되었다. 평판에 얇은 구리박판이 덮여 있는 시료와 증류수를 냉각제로 사용하여 초음파 유무, 경사각도의 변화 및 물의 과냉도 변화에 대하여 평판 가열면에서의 CHF를 측정하였다. 실험장치는 수조, 전원공급장치, 시험부, 초음파 발생장치, 데이터 획득장치 등으로 구성되었다. 실험조건은 3가지 과냉도에 대한 실험과 6가지 시편의 경사각도를 변화시켜 수행되었다. 측정값을 통해 초음파 진동이 CHF를 증진시키며, 그 영향은 경사각의 변화뿐만 아니라 과냉도에 따라서 크기가 달라지는 것을 알 수 있다. 초음파 진동에 의한 CHF증가율은 과냉도가 커질수록, 그리고 시편의 경사각도가 수직에서 수평하향 방향으로 기울어질수록 증가하였다. 가시화 실험을 통해 CHF 증가의 원인이 음장에서 기포 생성과 이탈의 동적거동과 밀접하게 관련되어 있음을 확인하였다.