• Title/Summary/Keyword: subcooling

Search Result 220, Processing Time 0.021 seconds

Effects of Micro-fin Structure on Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region (강제대류 및 핵비등영역에 있어서 마이크로 휜 형상이 분무냉각 열전달에 미치는 영향)

  • Kim, Yeung-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.983-990
    • /
    • 2010
  • In the present study, spray cooling heat transfer was experimentally investigated for the case in which water is sprayed onto the surfaces of micro-fins in forced convection and nucleate boiling regions. The experimental results show that an increase in the droplet flow rate improves heat transfer due to forced convection and nucleate boiling in the both case of smooth surface and surfaces of micro-fins. However, the effect of subcooling for fixed droplet flow rate is very weak. Micro-fins surfaces enhance the spray cooling heat transfer significantly. In the dilute spray region, the micro-fin structure has a significant effect on the spray cooling heat transfer. However, this effect is weak in the dense spray region. A previously determined correlation between the Nusselt number and Reynolds number shows good agreement with the present experimental data for a smooth surface.

A Comparative Study on the Formation of Zeolite-Methane Hyudrate (제올라이트-메탄 하이드레이트 생성에 대한 비교 연구)

  • Park, SungSeek;An, EoungJin;Kim, NamJin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.145.2-145.2
    • /
    • 2011
  • 메탄 하이드레이트는 낮은 온도와 높은 압력 조건에서 물분자들의 격자구조에 메탄가스분자가 포획되어 수소결합으로 형성되는 외관상 얼음과 비슷한 결정성 화합물이다. $1m^3$의 메탄 하이드레이트는 표준상태에서 $172m^3$의 메탄가스와 $0.8m^3$의 물로 분해되며, $-10^{\circ}C{\sim}-20^{\circ}C$의 온도에서는 하이드레이트 입자표면에서 생성되는 얼음막으로 인하여 상압에서도 안정하게 존재하는 자기보존 효과를 가지고 있다. 따라서 이와 같은 특징을 천연가스 수송 및 저장의 방법으로 이용할 경우 $-162^{\circ}C$의 초저온을 만들고 유지시키기 위하여 고가의 설비를 필요로 하는 기존의 LNG 수송방법을 대체할 수 있다. 특히 연간 천연가스 소비량을 0.4 ~ 1.0 million ton으로 가정했을 때, 하이드레이트 수송방법은 LNG 수송에 비해 18 ~ 25% 정도의 비용을 절약할 수 있는 경제적인 방법으로 알려져 있다. 그러나 하이드레이트를 인공적으로 제조할 경우 물분자와 가스분자의 반응율이 낮기 때문에 하이드레이트가 생성되기까지 많은 시간이 소요되며, 하이드레이트에 포획되는 가스분자의 양도 적다. 따라서 본 연구에서는 이와 같은 문제점을 해결하기 위하여 다공성 물질인 천연 제올라이트와 제올라이트 13X를 이용하여 제올라이트 혼합유체를 제조하였으며, 메탄가스와 반응시켜 하이드레이트를 생성시키는 실험을 수행하였다. 그 결과, 하이드레이트 생성 시 천연 제올라이트와 제올라이트 13X 모두 0.01 wt%의 혼합비율에서 가장 좋은 효과를 나타내었으며, 하이드레이트에 포획된 가스의 양은 같은 과냉도 조건에서 천연제올라이트와 제올라이트 13X 혼합유체를 이용하여 하이드레이트를 생성 시켰을 때, 증류수보다 각각 4배, 5배 높음을 보였다. 또한 낮은 과냉도에서 하이드레이트 생성 시 제올라이트, 제올라이트13X 혼합유체에서 하이드레이트 생성시간이 증류수에서 하이드레이트를 생성시킬 때보다 빨라짐을 확인하였다.

  • PDF

External Condensation Heat Transfer Coefficients of R245fa on Low Fin and Turbo-C Tubes (낮은 핀관과 Turbo-C 촉진관에서 R245fa의 외부 응축 열전달계수)

  • Shim, Yun-Bo;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.167-175
    • /
    • 2009
  • In this study, condensation heat transfer coefficients(HTCs) of R22, R123, R134a and R245fa are measured on both 26fpi low fin and Turbo-C tubes. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling of $3{\sim}8^{\circ}C$. Test results show that HTCs of the newly developed low vapor pressure alternative refrigerant, R245fa, are $7.8{\sim}9.2%$ and $10.3{\sim}18.6%$ higher than those of R123 for 26fpi low fin tube and Turbo-C tube respectively. For all refrigerants tested, HTCs of Turbo-C enhanced tube are higher than those of 26fpi low fin tube. For the low fin tube, Beatty and Katz's prediction equation yielded 20% deviation for all fluids. The heat transfer enhancement ratio of R245fa on the Turbo-C tube is $5.9{\sim}6.4$ while that of R123 is $5.7{\sim}5.9$. From the view point of environmental safety and condensation heat transfer, R245fa is a long term candidate to replace R123 currently used in centrifugal chillers.

Performance Comparison of R134a Organic Rankine Cycle (ORC) Using Hot Wastewater and Surface Seawater (온배수와 표층수를 이용하는 R134a용 유기 랭킨사이클의 성능 비교)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.768-773
    • /
    • 2012
  • This study was performed to find out the possibility that hot waste water from a thermoelectric power plant can be applied to Organic Rankine Cycle (ORC) by comparing the performance characteristics for use of the ocean surface water ($25^{\circ}C$) and hot waste water ($35^{\circ}C$) as a secondary fluid. The parameters considered in this study are four; superheating temperature, subcooling temperature, turbine efficiency, and pump efficiency. Main results of this study are summarized as follows : Overall efficiency of applying hot waste water to ORC is 87% higher than that of surface water. Thus it could be confirmed that hot waste water of the thermoelectric power plant can be applied to ORC.

Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions (운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성)

  • Baek, Seung-Moon;Son, Chang-Hyo;Heo, Jeong-Ho;Choi, In-Soo;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1021-1026
    • /
    • 2014
  • In this paper, among various systems applying hot-gas bypass control, outdoor temperature, outlet temperature of water cooler, superheating and subcooling degree, which are the factors affecting the performance of the system bypassing hot-gas to evaporator inlet were analyzed. The main results were summarized as following. Frist of all, performance of refrigeration system bypassing hot-gas to evaporator inlet was affected by outdoor temperature, outlet temperature of water cooler, superheating and sub cooling degree. Thus, providing basic planning date of refrigeration system obtained through optimization of variables is expectable. Thus, providing the basic design data of refrigeration system can be offered by performing the optimization of these variables. Also, the feasibility of this refrigeration system proposed in this paper was obtained by analyzing operating characteristics of the system bypassing hot-gas to evaporator inlet.

Validation of a CFD Analysis Model for the Calculation of CANDU6 Moderator Temperature Distribution (CANDU6 감속재 온도분포 계산을 위한 CFD 해석모델의 타당성 검토)

  • Yoon, Churl;Rhee, Bo-Wook;Min, Byung-Joo
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.499-504
    • /
    • 2001
  • A validation of a 3D CFD model for predicting local subcooling of moderator in the vicinity of calandria tubes in a CANDU reactor is performed. The small scale moderator experiments performed at Sheridan Park Experimental Laboratory(SPEL) in Ontario, Canada[1] is used for the validation. Also a comparison is made between previous CFD analyses based on 2DMOTH and PHOENICS, and the current model analysis for the same SPEL experiment. For the current model, a set of grid structures for the same geometry as the experimental test section is generated and the momentum, heat and continuity equations are solved by CFX-4.3, a CFD code developed by AEA technology. The matrix of calandria tubes is simplified by the porous media approach. The standard $k-\varepsilon$ turbulence model associated with logarithmic wall treatment and SIMPLEC algorithm on the body fitted grid are used and buoyancy effects are accounted for by the Boussinesq approximation. For the test conditions simulated in this study, the flow pattern identified is a buoyancy-dominated flow, which is generated by the interaction between the dominant buoyancy force by heating and inertial momentum forces by the inlet jets. As a result, the current CFD moderator analysis model predicts the moderator temperature reasonably, and the maximum error against the experimental data is kept at less than $2.0^{\circ}C$ over the whole domain. The simulated velocity field matches with the visualization of SPEL experiments quite well.

  • PDF

Crystallization of Benzene from Benzene-Cyclohexane Mixtures by Layer Melt Crystallization - Phenomena of Impurity Inclusion in Crystal - (경막형 용융결정화에 의한 벤젠-사이클로헥산 혼합물로부터 벤젠의 결정화-결정의 불순물 내포현상-)

  • Kim, Kwang-Joo;Lee, Jung-Min;Ryu, Seung-Kon
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.389-394
    • /
    • 1997
  • The distribution of impurity included in benzene layer crystal was explored in layer crystallization of cyclohexane and benzene mixtures. The influence of crystal growth rate on crystal purity was investigated. All experimental results for bezene-cyclohexane system obtained in layer crystallizer have been evaluated with the criterion of Wintermantel. The purity of crystal decreases with increasing degree of subcooling, decreasing feed concentration and increasing crystal growth rate. The crystal growth rate was a key parameter to determine the inclusion of impurity in crystals. The results obtained from runs performed at increasing crystallization time(i.e. crystal thickness) have clearly shown that migration of inclusions within crystal layer to the melt, leading to the removal of impurity occurs. The diffusion of impurity which takes place during the crystallization from the beginning, enhances a further purification of the crystal layer if that underwent a thermal gradient after growth of the layer crystal stops.

  • PDF

A numerical study on the performance of a heat pump assisted dryer (열펌프 건조기의 성능에 관한 수치해석)

  • Kim, I.G.;Park, S.R.;Koh, J.Y.;Kim, Y.J.;Kim, J.G.;Yim, C.S.
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.91-104
    • /
    • 1998
  • This study carried out a numerical analysis on a heat pump assisted dryer using HFC134a. Under the constant degree of superheat and that of subcooling, we analyzed the performance of heat pump assisted dryer with varying an air mass velocity, bypass air ratio, compressor speed and an inlet bulb temperature of dryer. Simulation results were compared with experimental results, so they were maximally agreed in the range of 10%. There was the proper bypass air ratio with varying an air mass velocity. As for the effect of SMER having the inlet temperature $35^{\circ}C$ and compressor speed 1360rpm, bypass air ratio was 30% at the front velocity 0.5kg/s, 40% at the front velocity 0.7kg/s and 50% at the front velocity 0.9kg/s and 1.1kg/s. As the compressor speed was increased, SMER decreased and COP increased. As the inlet bulb temperature was increased, SMER and COP decreased.

  • PDF

Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser (응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험)

  • 김창덕;박일환;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.

Development of cascade refrigeration system using R744 and R404A - Prediction and comparison on maximum COP(Coefficient of Performance) - (R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(2) - 최대 성능계수에 관한 예측과 비교 -)

  • Oh, Hoo-Kyu;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.189-195
    • /
    • 2011
  • In this paper, prediction and comparison on COP(coefficient of performance) of R744-R404A cascade refrigeration system are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, compressor efficiency, and condensing and evaporating temperature in the R404A high- and R744 low-temperature cycle, respectively. The main results were summarized as follows : The prediction for performance of R744-R404A cascade refrigeration system have been proposed through multiple regression analysis and compared with other researcher's correlations. As a result, prediction proposed in the study shows disagreement with existing equations. Therefore, it is necessary to propose the more accurate correlation predicting the COP of R744-R404A cascade refrigeration system through an addition experiments.