• 제목/요약/키워드: subcooling

검색결과 220건 처리시간 0.027초

The Generic Analysis Method for Core Flow Instability

  • Jun, Byung-Soon;Park, Eung-Jun;Park, Jong-Ryool
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.335-341
    • /
    • 1997
  • The generic analysis method for core flow instability is suggested to confirm that the core flow instability would not occur on PWR conditions. For the confirmation, the stability criteria of each fuel type are provided. Instability investigations in various accident conditions prove that the locked rotor accident is the most limiting case to instability. Parametric Effects are surveyed and in good agreement with available studies. The effects of heat flux distribution become negligible as the subcooling number is decreased. The power margin to instability is calculated quantitatively in various accident conditions.

  • PDF

환상유로에서의 임계열유속에 관한 실험적 연구

  • 천세영;전형길;정흥준;문상기;민경호;정문기
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.343-348
    • /
    • 1996
  • 한국원자력연구소에서는 광범위한 열유동조건에서 CHF 실험을 수행하기 위해 고온, 고압으로 운전할 수 있는 RCS 열수력 Loop를 제작하고 기초 실험자료를 얻기 위해 환상 유로에서 CHF 측정실험을 수행하였다. 실험은 압력 1.82Mpa, 질량유속 300~566kg/$m^2$.s Test Section입구 Subcooling 18$^{\circ}C$ 및 47$^{\circ}C$의 범위에서 수행되었다. CHF 실험자료와 Doerffer의 CHF 상관식을 비교한 결과 상관식은 실험치 보다 최고 160% 크게 예측하였고 Doerffer 상관식은 저유량 영역에서 적용이 어려워질 것으로 예상되었다. 따라서 저유량 영역의 체계적인 CHF 실험자료가 필요하다.

  • PDF

$NH_3-CO_2$를 사용하는 이원 냉동 시스템의 성능 분석 (Performance Analysis of an Ammonia(R717) and Carbon Dioxide(R744) Two-Stage Cascade Refrigeration System)

  • 손창효
    • 한국가스학회지
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2010
  • 본 논문은 암모니아-이산화탄소용 이원 냉동시스템의 작동변수에 대한 최적의 설계자료를 제공하고자 이원 냉동시스템의 사이클 성능을 분석하였다. 작동변수로는 암모니아용 고온사이클과 이산화탄소용 저온사이클내의 과냉각도와 과열도, 압축기효율, 응축과 증발온도이다. 이에 대한 주요결과를 요약하면 다음과 같다. 이원 냉동사이클의 과냉도가 증가할수록 COP는 증가하는 반면 과열도가 증가할수록 COP는 감소하는 것을 알 수 있다. 이원 냉동사이클의 응축온도가 증가할수록 이원 냉동사이클의 COP는 증가하는 반면 증발온도가 증가할수록 COP가 감소함을 알 수 있다. 또한, 이원 냉동사이클의 압축효율이 증가할수록 COP가 증가한다. 따라서, 과열도, 과냉각도, 압축효율, 증발온도, 응축온도 등의 인자들이 R717과 R744용 이원 냉동사이클의 COP에 영향을 미친다.

경막 결정화기에서 벤젠-시클로헥산 혼합물로부터 벤젠의 결정성장속도 (Layer Growth Rate of Benzene Layer from Benzene-Cyclohexane Mixtures in Layer Crystallizer)

  • 김광주;이정민;유승곤
    • 공업화학
    • /
    • 제7권2호
    • /
    • pp.308-314
    • /
    • 1996
  • 경막형 결정화기에서 벤젠-시클로헥산 혼합물로부터 벤젠의 결정성장속도가 조사되었다. 결정성장속도는 경막결정화기의 냉각벽에 부착되는 결정의 양으로부터 얻어진 결정두께와 시간에 대한 상관관계식으로부터 결정되었다. 결정성장속도와 결정의 표면온도와, 용융액의 온도의 차로 정의되는 과냉각정도와의 상관관계가 얻어졌다. 이 이성분 공융계에 대한 결정성장속도는 과냉각정도의 2승에 비례하였다. 경막결정화기의 열전달 및 물질전달 속도에 근거하여 결정의 표면온도 및 결정두께를 예측할 수 있는 모델식이 제시되었다. 5wt% 및 10wt%의 시클로헥산을 포함한 벤젠-시클로헥산 혼합물에 대하여 여러 다른 냉각온도에서 실험적으로 얻어진 결정두께의 자료와 모델식으로 계산된 결과가 비교되었다.

  • PDF

작동변수에 따른 R744용 해양온도차 발전 사이클의 엑서지 분석 (Exergy Analysis of R744 OTEC Power Cycle with Operation Parameters)

  • 윤정인;손창효;백승문;김현주;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1036-1042
    • /
    • 2012
  • 본 논문은 R744용 해양온도차 발전 시스템의 운전변수에 대한 최적의 설계를 위해서 엑서지효율을 이론적으로 분석하였다. 본 연구에서 고려된 작동변수로는 과열도와 과냉각도, 증발온도와 응축온도, 터빈과 펌프 효율 등이다. 분석한 결과를 요약하면 다음과 같다. R744용 해양온도차 발전 사이클의 증발온도, 과열도, 터빈효율, 펌프효율이 증가할수록 엑서지 효율은 증가한다. 그러나 응축온도와 과냉각도는 증가할수록 엑서지 효율이 감소한다. 이 중에서 증발온도의 변화가 R744용 해양온도차 발전 사이클의 엑서지 효율에 가장 크게 영향을 미치고, 펌프효율이 가장 적게 영향을 미친다. 따라서 R744용 해양온도차 발전 사이클의 엑서지 효율을 증가시키기 위해서는 증발온도를 표층수 온도에 가장 근접하게 증가시키는 것이 유리하다.

단열 모세관내 R600a의 유동 특성 (Flow Characteristics of R600a in an Adiabatic Capillary Tube)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.449-454
    • /
    • 2010
  • 본 논문은 균질유동모델을 적용하여 단열 모세관내 R600a의 유동 특성을 이론적으로 조사하였다. 이 모델은 시뮬레이션 해석에 필요한 기본적인 질량, 에너지, 운동량 방정식에 근거하고 있다. 또한 2개의 마찰인자와 점성계수모델을 이용하여 유동특성을 조사하였다. R600a의 열역학 및 전달 물성치는 EES 물성치 코드를 이용하여 계산하였다. 작동변수들에 대한 기초 설계자료를 제공하고자 단열 모세관내 R600a의 유동 특성을 분석하였다. 본 연구의 작동변수에는 응축온도, 증발온도, 과냉각도, 모세관의 직경이 있다. 주요 결과를 요약하면 다음과 같다. R600a용 단열 모세관내 응축온도, 증발온도, 과냉각도, 관직경은 모세관 전체길이에 영향을 준다. 즉 R600a용 모세관 전체길이는 식(15)와 같은 상관식으로 나타낸다.

천연 제올라이트와 합성 제올라이트 5A를 이용한 메탄 하이드레이트의 생성에 대한 비교 연구 (A Comparative Study on the Formation of Methane Hydrate Using Natural Zeolite and Synthetic Zeolite 5A)

  • 박성식;박윤범;김남진
    • 신재생에너지
    • /
    • 제8권2호
    • /
    • pp.24-32
    • /
    • 2012
  • Natural gas hydrates have a high potential as the 21st century new energy resource, because it have a large amount of deposits in many deep-water and permafrost regions of the world widely. Natural gas hydrate is formed by physical binding between water molecule and gas mainly composed of methane, which is captured in the cavities of water molecules under the specific temperature and pressure. $1m^3$ methane hydrate can be decomposed to the methane gas of $172m^3$ and water of $0.8m^3$ at standard condition. Therefore, there are a lot of practical applications such as separation processes, natural gas storage transportation and carbon dioxide sequestration. For the industrial utilization of methane hydrate, it is very important to rapidly manufacture hydrate. However, when methane hydrate is artificially formed, its reaction time may be too long and the gas consumption in water becomes relatively low, because the reaction rate between water and gas is low. So in this study, hydrate formation was experimented by adding natural zeolite and Synthetic zeolite 5A in distilled water, respectively. The results show that when the Synthetic zeolite 5A of 0.01 wt% was, the amount of gas consumed during the formation of methane hydrate was higher than that in the natural zeolite. Also, the natural zeolite and Synthetic zeolite 5A decreased the hydrate formation time to a greater extent than the distilled water at the same subcooling temperature.

R744-R404A용 캐스케이드 냉동시스템 개발에 관한 연구(1) - 성능 특성에 관한 분석 - (Development of Cascade Refrigeration System Using R744 and R404A - Analysis on Performance Characteristics -)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.182-188
    • /
    • 2011
  • 본 논문은 R744-R404A용 캐스케이드 냉동시스템의 기초 설계자료를 제공하기 위해서 성능특성에 대해 분석하였다. 작동변수로는 R404A용 고온사이클과 R744용 저온사이클의 과냉각도와 과열도, 압축효율, 응축과 증발온도이다. 이에 대한 주요결과를 요약하면 다음과 같다. 고온사이클에만 과열도를 주는 것이 가장 높은 COP를 가지는 반면에 저온 고온사이클 모두에 대해 과냉도를 주는 것이 가장 높은 COP를 가진다. 과열도, 과냉각도, 압축효율, 증발온도, 응축온도 등의 인자들이 R744와 R404A용 캐스케이드 냉동사이클의 COP에 영향을 미치는 것을 확인할 수 있었고, 이들 각각의 인자들은 캐스케이드 냉동사이클의 성능을 최대로 하는 캐스케이드 증발온도가 존재함을 알 수 있었다.

천연제올라이트를 이용한 메탄 하이드레이트 생성에 대한 연구 (A Study on the Methane Hydrate Formation Using Natural Zeolite)

  • 박성식;안웅진;김대진;전용한;김남진
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.259-264
    • /
    • 2011
  • Gas hydrate is formed by physical binding between water molecule and gas such as methane, ethane, propane, or carbon dioxide, etc., which is captured in the cavities of water molecule under the specific temperature and pressure. $1\;m^3$ hydrate of pure methane can be decomposed to the methane gas of $172\;m^3$ and water of $0.8\;m^3$ at standard condition. If this characteristic of hydrate is reversely utilized, natural gas is fixed into water in the form of hydrate solid. Therefore, the hydrate is considered to be a great way to transport and store of natural gas in large quantity. Especially the transportation cost is known to be 18~25% less than the liquefied transportation. However, when methane gas hydrate is artificially formed, its reaction time may be too long and the gas consumption in water becomes relatively low, because the reaction rate between water and gas is low. Therefore, for the practical purpose in the application, the present investigation focuses on the rapid production of hydrates and the increment of the amount of captured gas by adding zeolite into pure water. The results show that when the zeolite of 0.01 wt% was added to distilled water, the amount of captured gas during the formation of methane hydrate was about 4.5 times higher than that in distilled water, and the methane hydrate formation time decreased at the same subcooling temperature.

자동차용 리시버/건조기 일체형 응축기의 성능해석 (Performance Analysis of Integral Receiver/Dryer Condenser for Automobile)

  • 원성필
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.245-252
    • /
    • 2007
  • The important problems from the point of view of preventing global warming are to save the power consumption of automotive air-conditioning systems and reduce the refrigerant amount filled. To achieve such requirements, integral receiver/dryer (R/D) condensers were developed recently. Typical integral R/D condensers have extra headers that play the role of R/D. Except an extra header and somewhat complex tube array resulting from the extra header, the most integral R/D condensers have almost the same specification that tube has multi channels, fin has louvers, flow in tube is parallel, etc. When integral condensers are applied, it is known that the refrigerating effect increases, resulting from the increase of subcooling degree in condenser, and the refrigerant amount used saves. In spite of several merits, integral condensers have not been applied a lot. That is why there is an uncertainty in performance, using integral condensers. The objective of this study is to theoretically optimize the tube array in an integral R/D condenser that is really being applied to some vehicles. The tube array has a great effect on the performance of the integral condenser as well as common ones. Through computer simulation, we could see that the tube array, 14-6-3-5-3-4, in the same condenser was the best, comparing heat release rate, pressure drop, etc. to the real array, 17-5-3-3-2-5. It should be noted that the optimization is based on the condenser performance only.