• Title/Summary/Keyword: study room

Search Result 8,226, Processing Time 0.039 seconds

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel. undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesio-distally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference on fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even of that portion consists of mainly enamel and a little dentin structure.

  • PDF

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

The Effect of Corticosteroid in Conservative Treatment of Patients with Hemoptysis (객혈 환자의 보존적 치료에서 겉질스테로이드의 효과)

  • Kwon, Jee Suk;Yoo, Seung Soo;Kang, Yeh Rim;Lee, Jeong Woo;Kim, Eun Jin;Cha, Seung Ick;Park, Jae Yong;Jung, Tae Hoon;Kim, Chang Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.486-490
    • /
    • 2007
  • Background: This study examined the effect of corticosteroids as a short-term treatment for patients with hemoptysis that requires conservative treatment including bed rest, antitussives and antibiotics. Methods: From February 2005 to August 2006, 78 consecutive patients who visited the emergency room because of hemoptysis were enrolled in the study. Patients with hemoptysis due to lung cancer, active pulmonary tuberculosis, and pneumonia were excluded. The 78 patients were divided randomly into a corticosteroid medication group (n=37) and a control group (n=41). The mean control time of hemoptysis, mean in-hospital days, and complications of treatment were investigated prospectively. Results: For the etiology of hemoptysis, inactive pulmonary tuberculosis alone or its associated complications (bronchiectasis and/or aspergilloma) were the most common causes (51%); bronchiectasis alone and bronchitis were the next most common causative diseases (15%, respectively). The patients' characteristics and symptoms in the corticosteroid medication and control groups were similar. The steroid medication group showed a significantly lower mean control time of hemoptysis than the control group ($4.0{\pm}2.7$ days, $6.1{\pm}4.8$ days, respectively) (p=0.022) and had a lower mean number of in-hospital days ($5.8{\pm}3.4$ days, $7.9{\pm}4.8$ days, respectively) (p=0.036). There were no significant complications, such as hospital-acquired pneumonia or gastrointestinal bleeding, related to the use of corticosteroids. Conclusion: The use of corticosteroids as a conservative treatment for hemoptysis due to bronchitis, bronchiectasis, inactive pulmonary tuberculosis and its related complications safely reduces the control time of hemoptysis as well as the number of in-hospital days.

Quality characteristics of fresh-cut Dioscorea bulbifera treated under various blanching conditions prior to vacuum-packaging during storage (블랜칭 처리에 의한 신선편이 둥근마의 저장 중 품질 특성)

  • Seong, Bong Jae;Kim, Sun Ick;Jee, Moo Geun;Kim, Soo Dong;Kwon, A Reum;Kim, Hyun Ho;Lee, Ka Soon
    • Food Science and Preservation
    • /
    • v.24 no.5
    • /
    • pp.565-575
    • /
    • 2017
  • This study was carried out to investigate shelf-life and quality of fresh-cut Dungkunma (Dioscorea bulbifera) in order to elevate utilization of Dungkunma a fresh food. Before vacuum-packaging (in polyethylene/polypropylene film ($100{\mu}m$, $15{\times}20cm$, $75{\pm}2cmHg$) and storaging at $2^{\circ}C$, Dungkunma was peeled out and cut to dice type ($2.0{\pm}0.5cm^3$), and then washed and blanched using hot water (at $90{\pm}2^{\circ}C$ with 2% NaCl solution for 30 sec). Blanched Dungkunma was pre-dried at room temperature, $40^{\circ}C$ and $50^{\circ}C$ for removing surface water. Each peeled dice Dungkunma was packed 50 g in polyethylene/polypropylene film ($100{\mu}m$, $15{\times}20cm$) with vacuum treatment ($75{\pm}2cmHg$) and stored at $2^{\circ}C$ for 90 days. Hardness and adhesiveness of Dungkunma blanched by 2% NaCl and pre-dried at $50^{\circ}C$ (SB50) were the highest, but changes were the least during storage. Lightness and yellowness of stored Dungkunma in all treatments decreased slightly while redness increased during storage. Changes of color of SB50 was the least. Total concentration of aerobic bacteria in SB50 was $1.88{\pm}0.18log\;CFU/g$ during 90 days and E. coli was detected in all treatments during whole storage periods. Dioscin and allantoin contents of SB50 were virtually unchanged during the storage. Consequently, the results of this study suggest that vacuum packaged Dungkunma after blanching using 2% NaCl solution could be effective to prolong the quality of fresh-cut Dungkunma.

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel, undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesiodistally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference in fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even if that portion consists of mainly enamel and a little dentin structure.

Students' and Parents' Perceptions of Nutrition Education in Elementary Schools (초등학교 영양교육에 대한 학생과 학부모의 인식도 조사)

  • Kim, Hyun-Hee;Park, Yoo-Hwa;Shin, Eun-Kyung;Shin, Kyung-Hee;Bae, In-Sook;Lee, Yeon-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.8
    • /
    • pp.1016-1024
    • /
    • 2006
  • The purpose of this study was to investigate students' and parents' perceptions of nutrition education. In this survey, 7,577 elementary school students and 6,003 of their parents across the country were surveyed about the necessity of implementing nutrition education, its present status and problems and future methods for nutrition education implementation. The results showed that 96.6% of the parents and 62.8% of the students responded that nutrition education was urgently needed, at least once per week in the lower grades of elementary school, and that it should be related to and coordinated with special activities class. In addition, the survey showed that students and their parents wanted nutrition teachers to establish a nutrition counseling room, a practical cooking class, a special activity class, and/or dietary camp during school breaks. With regard to the status of nutrition education at home, there was statistical evidence that suggests significant differences between urban and rural schools. Approximately 63% of the parents indicated that they had difficulty teaching nutrition education in their own homes, because it was difficult to determine the dietary habits and nutritional status of their children. When asked about attending a dietary class for parents, 74% expressed their intent to attend. Parents were most interested in learning about cooking practices, diet therapy, and food information in that order. The results showed that the most effective method of dietary education was to teach appropriate nutritional practices in school and at home simultaneously. Hence, necessary information and education should be provided through special lectures, special cooking classes, and dietary classes for parents. The conclusions of this study suggest that a variety of education programs should be developed to achieve effective nutrition education for students and their parents.

Factors Influencing on the Drop of in vitro Protein Digestibility in Dried Fish Meat (건어육(乾魚肉) 저장(貯藏)중의 단백질(蛋白質) 소화율(消化率) 저하요인(低下要因))

  • Kim, Sang-Ae;Lee, Kang-Ho;Ryu, Hong-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.1
    • /
    • pp.45-55
    • /
    • 1986
  • This paper aims to study the reactions of lipid or oxidized lipid with protein during drying and storing hair tail fish(Trichurus lepturus) and flounder(Kanakius kitaharai) being generally consumed as dried seafood products in Korea and their influence on the drop of in vitro protein digestibility of these fish meat. The results of the study are as follows: The digestibility of the raw materials of flounder and hair tail fish was 87.63% and 86.08% respectively, and that of sundried and hot air dried materials went down $1{\sim}2$ percent with drying process. But in case of defatted and sundried materials, the rate increased 85.15% and 87.15% respectivley. After 30 days of storage, the digestibility decreased in all materials, and hot air dried meat showed a significant decrease. Trypsin indigestible substrate (TIS) contents of flounder and hair tail fish, in case of raw materials were 0.88 and 0.96mg/g. solid repectiveiy and in case of defatted and sundried materials, TIS contents showed a low increase and digestibility showed a high increase. Brown pigment formation had a wide range of increase in case of the sundried and hot air dried materials and it was increased with duration of storage and temperature. The major fatty acids in the fats of hair tail fish and flounder were $C_{18:1},\;C_{16:0},\;C_{22:6}\;and\;C_{16:1}$ and rate of unsaturated to saturated fatty acids was 79.2:20.8 for flounder, 67.8:32.2 for hair tail fish. After 30 days of storage at room temperature. saturated fatty acids increased compared with the raw materials while unsaturated fatty acids showed a tendency to decrease. Avaialble lysine of hair tail fish was higher than that of flounder and both of them lost about 8.23% of that in raw materials after 30 days of storage.

  • PDF

Characteristics of Sand-Silt Mixtures during Freezing-Thawing by using Elastic Waves (탄성파를 이용한 모래-실트 혼합토의 동결-융해 특성)

  • Kang, Mingu;Kim, Sangyeob;Hong, Seungseo;Kim, Youngseok;Lee, Jongsub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.47-56
    • /
    • 2014
  • In winter season, the pore water inside the ground freezes and thaws repetitively due to the cold air temperature. When the freezing-thawing processes are repeated on the ground, the change in soil particle structure occurs and thus the damage of the infrastructure may be following. This study was performed in order to investigate the stiffness change of soils due to the freeze-thaw by using elastic waves. Sand-silt mixtures are prepared with in the silt fraction of 40 %, 60 % and 80 % in weight and in the degree of saturation of 40 %. The specimens are placed into the square freezing-thawing cell by the temping method. For the measurement of the elastic waves, a pair of the bender elements and a pair of piezo disk elements are installed on the cell, and a thermocouple is inserted into soils for the measurement of the temperature. The temperature of the mixtures is decreased from $20^{\circ}C$ to $-10^{\circ}C$ during freezing, is maintained at $-20^{\circ}C$ for 18 hours, is gradually increased up to the room temperature of $20^{\circ}C$ to thaw the specimens. The shear waves, the compressional waves and the temperature are measured during the freeze-thaw process. The experimental result indicates that the shear and the compressional wave velocities after thawing are smaller than those of before freezing. The velocity ratio of after thawing to before freezing of shear wave is smaller than that of the compressional wave. As silt fraction increases from 40 % to 80 %, the shear and compressional wave velocities are gradually increased. This study suggests that the freezing-thawing process in unsaturated soil loosens the soil particle structure, and the shear wave velocity reflects the effect of freezing-thawing more sensitively than the compressional wave velocity.

A Study of Hydrodynamics and Reaction Characteristics in Relation to the Desulfurization Temperatures of Zn-Based Solid Sorbent in the Lab-scale High Pressure and High Temperature Desulfurization Process (실험실규모 고온고압건식탈황공정의 수력학적 특성 및 탈황온도에 따른 아연계 탈황제의 반응특성 연구)

  • Kyung, Dae-Hyun;Kim, Jae-Young;Jo, Sung-Ho;Park, Young Cheol;Moon, Jong-Ho;Yi, Chang-Keun;Baek, Jeom-In
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.492-498
    • /
    • 2012
  • In this study, hydrodynamics such as solid circulation rate and voidage in the desulfurizer and the reaction characteristics of Zn-based solid sorbents were investigated using lab-scale high pressure and high temperature desulfurization process. The continuous HGD (Hot Gas Desulfurization) process consist of a fast fluidized bed type desulfurizer (6.2 m tall pipe of 0.015 m i.d), a bubbling fluidized bed type regenerator (1.6 m tall bed of 0.053 m i.d), a loop-seal and the pressure control valves. The solid circulation rate was measured by varying the slide-gate opening positions, the gas velocities and temperatures of the desulfurizer and the voidage in the desulfurizer was derived by the same way. At the same gas velocities and the same opening positions of the slide gate, the solid circulation rate, which was similar at the temperature of $300^{\circ}C$ and $550^{\circ}C$, was low at those temperatures compared with a room temperature. The voidage in the desulfurizer showed a fast fluidized bed type when the opening positions of the slide gate were 10~20% while that showed a turbulent fluidized bed type when those of slide gate were 30~40%. The reaction characteristics of Zn-based solid sorbent were investigated by different desulfurization temperatures at 20 atm in the continuous operation. The $H_2S$ removal efficiency tended to decrease below the desulfurization temperature of $450^{\circ}C$. Thus, the 10 hour continuous operation has been performed at the desulfurization temperature of $500^{\circ}C$ in order to maintain the high $H_2S$ removal efficiency. During 10 hour continuous operation, the $H_2S$ removal efficiency was above 99.99% because the $H_2S$ concentration after desulfurization was not detected at the inlet $H_2S$ concentration of 5,000 ppmv condition using UV analyzers (Radas2) and the detector tube (GASTEC) which lower detection limit is 1 ppmv.