• 제목/요약/키워드: stud

검색결과 543건 처리시간 0.021초

Tilt Rotor-Wing Concept for Multi-Purpose VTOL UAV

  • Hwang, Soo-Jung;Kim, Yu-Shin;Lee, Myeong-Kyu
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권1호
    • /
    • pp.87-94
    • /
    • 2007
  • Tilt rotor-wing concept to show enhanced performance in low speed mission is presented. Three types of stud wings on the existing tilt rotor configuration are suggested and their characteristics are compared. Aerodynamic analysis indicates that the stud wing concept gives significant performance improvement on the endurance and range in the low speed regime when compared with the tilt rotor. Penalties of the stud wing are discussed from the perspectives of conversion corridor, structural weight, configuration design, and cross wind stability. This study concludes that the advantage of the stud wing in general UAV mission performance is so significant as to surpass the penalties in other perspectives investigated.

조립형 건식벽체의 차음성능 개선 공법에 관한 연구 (Method of how to improve transmission loss of dry walls)

  • 김경호;전진용;김성훈;이형기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.719-724
    • /
    • 2013
  • In the case of newly developed stud which has more performance of sound transmission loss, it is expected that sound would transmit through runner than stud. so we developed construction method of runner and stud. As a result, sound transmission loss is improved about 2 dB by using this method. But this construction method could be applied to only newly developed stud. In addition, sound leak of wall joint is about 2 dB, and it could be improved by using rubber gasket at joint.

  • PDF

전자기기 케이스를 위한 마그네슘 판재 스터드 용접 기술에 관한 연구 (A study for CD stud welding of Magnesium alloy for electric device case)

  • 이목영;류충선;장웅성;최상운
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.53-56
    • /
    • 2007
  • Magnesium sheet used in electrical device due to mobility and EMF shielding characteristics. Magnesium case by press forming was advantageous compare with conventional die casting process, because of its thin gauge of wall and surface quality. But it need to makes the boss to fix inner part or assemble the case. CD stud welding was effective way for joining the boss to the thin gauge case of the electrical devices. In this study, we investigated the performances of the magnesium boss welder To measure the process parameters such as the force and the weld current, we design the monitoring system for CD stud welding. We test the characteristics of CD stud welding for AZ31 sheets at some variables. Finally we select the optimum welding range of magnesium sheets in CD stud welding process.

  • PDF

차륜형장갑차 고경도장갑강에 대한 스터드 용접의 적용 (STUD Welding on High Hardness Armor Steel of KWV)

  • 조환휘;신용철;이희준
    • 한국군사과학기술학회지
    • /
    • 제19권5호
    • /
    • pp.567-573
    • /
    • 2016
  • GMAW and GTAW processes have been used for welding of equipment mounting pads during decades. For improving the mobility and survivability of KWV(Korean Wheeled Vehicle), various types of equipment are required and numbers of pads for welding were increased. In this research, for improving productivity of mounting pads welding process, new technology of stud welding was studied. In this study, mechanical properties of stud weldment were investigated to compare with those of GMAW weldment. Also, research of stud weldment durability was carried out and proved its fatigue strength under the condition of KWV's 32,000 km load profile.

Bond-slip effect in steel-concrete composite flexural members: Part 2 - Improvement of shear stud spacing in SCP

  • Lee, WonHo;Kwak, Hyo-Gyoung;Kim, Joung Rae
    • Steel and Composite Structures
    • /
    • 제32권4호
    • /
    • pp.549-557
    • /
    • 2019
  • The use of shear studs usually placed in the form of mechanical shear connectors makes it possible to adopt composite steel-concrete structures in various structures, and steel-concrete plate composite (SCP) is being seriously considered for the installation of storage tanks exposed to harsh environments. However, manufacturing of SCP must be based on the application of existing design guidelines which require very close arrangement of shear studs. This means that the direct application of current design guidelines usually produces very conservative results and close arrangement of shear studs precludes pouring concrete within exterior steel faceplates. In this light, an improved guideline to determine the stud spacing should be introduced, and this paper proposes an improved ratio of the stud spacing to the thickness of steel plate on the basis of numerous parametric studies to evaluate the relative influence of the stud spacing on the stability of the SCP.

Shear resistance of stud connectors in high strength concrete

  • Lee, Young Hak;Kim, Min Sook;Kim, Heecheul;Kim, Dae-Jin
    • Structural Engineering and Mechanics
    • /
    • 제52권4호
    • /
    • pp.647-661
    • /
    • 2014
  • The use of steel-concrete composite members has been significantly increased as they have the advantages of the reduction of cross sectional areas, excellent ductility against earthquake loadings and a longer life span than typical steel frame members. The increased use of composite members requires an intensive study on the shear resistance evaluation of stud connectors in high strength concrete. However, the applicability of currently available standards is limited to composite members with normal and lightweight strength concrete. In this paper, push-out tests were performed on 24 specimens to investigate the structural behavior and shear resistance of stud connectors in high strength concrete. Test parameters include the existence of shear studs, height to diameter ratio of a shear stud, its diameter and concrete cover thickness. A shear resistance equation of stud connectors is proposed through a linear regression analysis based on the test results. Its accuracy is compared with those of existing shear resistance equations for studs in normal and lightweight concrete.

냉간 비조질강을 이용한 볼 스터드의 정형가공 공정연구 (Net Shape Forming Process for Ball Stud Using High Strength Micro-Alloyed Cold Forging Steel)

  • 윤덕재;최호준;이형욱;이근안;장병록;서성렬;최석우
    • 소성∙가공
    • /
    • 제15권8호
    • /
    • pp.562-567
    • /
    • 2006
  • Micro-alloyed steel or heat-treatment-free used in clean technology have been replacing for conventional quenched-and-tempered structural steels since the micro-alloyed forging steel was developed in early 1970s in Germany for saving money of heat treatment, simplified process, short delivery and good productivity. In this paper, ball stud assembled in steering system for automobile was selected to compare conventional process making heat treatment with new process using high strength micro-alloyed steel without heat treatment. The conventional process for ball stud was composed of a total of 6 steps including upsetting, forward extrusion, machining, burnishing and tread rolling with heat treatment and shot blasting. As opposed to conventional process, newly proposed process for ball stud using the clean technology without heat treatment is simplified such as forward extrusion, heading, upsetting, forming having a flange shape and tread rolling. Also net shape forming process to achieve specified process not to include machined step fur manufacturing the ball stud was applied to newly simplified process since micro-alloyed steel is difficult to be formed.

Shear and tensile behaviors of headed stud connectors in double skin composite shear wall

  • Yan, Jia-Bao;Wang, Zhe;Wang, Tao;Wang, Xiao-Ting
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.759-769
    • /
    • 2018
  • This paper studies shear and tensile behaviors of headed stud connectors in double skin composite (DSC) structure. Firstly, 11 push-out tests and 11 tensile tests were performed to investigate the ultimate shear and tensile behaviors of headed stud in DSC shear wall, respectively. The main parameters investigated in this test program were height and layout of headed stud connectors. The test results reported the representative failure modes of headed studs in DSC structures subjected to shear and tension. The shear-slip and tension-elongation behaviors of headed studs in DSC structures were also reported. Influences of different parameters on these shear-slip and tension-elongation behaviors of headed studs were discussed and analyzed. Analytical models were also developed to predict the ultimate shear and tensile resistances of headed stud connectors in DSC shear walls. The developed analytical model incorporated the influence of the dense layout of headed studs in DSC shear walls. The validations of analytical predictions against 22 test results confirmed the accuracy of developed analytical models.

행거로 보강된 스터드 접합부의 인장거동에 관한 실험적 연구 (Experimental Study on the Tensile Behaviors of Stud Connection with Hanger)

  • 김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권4호
    • /
    • pp.231-238
    • /
    • 2004
  • 본 논문은 스터드를 사용한 철근콘크리트 부재와 철골 부재의 접합부의 인장거동에 관한 연구를 나타내었다. 스터드 접합부의 인장 및 휨 성능을 향상시키기 위하여 행거를 스터드 주위에 설치하였다. 행거로 보강된 스터드 접합부의 인장 성능을 평가하기 위하여 철근비, 행거 상세, 묻힘길이 등을 변수로 한 8 개의 실험체를 계획하였다. 인장실험을 통하여 행거 보강이 접합부의 인장강도를 증가시키는데 매우 효과적인 것을 알 수 있었다. 기준식에 의한 인장강도 평가로부터 CCD식이 강도 산정에 보다 적합한 것으로 나타났다.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.