• Title/Summary/Keyword: structure detection

Search Result 2,026, Processing Time 0.029 seconds

Validation of the Korean Version of the Talent Development Environment Questionnaire for Sport (한국판 스포츠영재육성환경질문지(TDEQ) 타당성 검증)

  • Choi, Young-Jun;Hwang, Seunghyun
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.5
    • /
    • pp.207-219
    • /
    • 2015
  • The purpose of this study was to test the validation of the Korean version of the Talent Development Environment Questionnaire for sport(TDEQ; Martindale et al., 2010), developed through the conceptual and statistical verification stages(substantive stage-structural stage-external stage). In accordance with the procedure of translation, the substantive concepts of the items were reviewed. The data were collected from a sample of 244 ; 117 high school student-athletes and 127 university student-athletes. In order to test the internal structure of TDEQ, EFA/CFA, and internal consistency were performed. As a result, Korean version of the TDEQ had 5 factors with 38 items. External relationship by correlation analysis and group differentiation analysis were obtained to enhance the validity of the test. Overall, the Korean TDEQ will be used as a diagnostic and evaluation tool at the stage of detection, identification, selection, and development of Sport Talent.

A numerical application of Bayesian optimization to the condition assessment of bridge hangers

  • X.W. Ye;Y. Ding;P.H. Ni
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.57-68
    • /
    • 2023
  • Bridge hangers, such as those in suspension and cable-stayed bridges, suffer from cumulative fatigue damage caused by dynamic loads (e.g., cyclic traffic and wind loads) in their service condition. Thus, the identification of damage to hangers is important in preserving the service life of the bridge structure. This study develops a new method for condition assessment of bridge hangers. The tension force of the bridge and the damages in the element level can be identified using the Bayesian optimization method. To improve the number of observed data, the additional mass method is combined the Bayesian optimization method. Numerical studies are presented to verify the accuracy and efficiency of the proposed method. The influence of different acquisition functions, which include expected improvement (EI), probability-of-improvement (PI), lower confidence bound (LCB), and expected improvement per second (EIPC), on the identification of damage to the bridge hanger is studied. Results show that the errors identified by the EI acquisition function are smaller than those identified by the other acquisition functions. The identification of the damage to the bridge hanger with various types of boundary conditions and different levels of measurement noise are also studied. Results show that both the severity of the damage and the tension force can be identified via the proposed method, thereby verifying the robustness of the proposed method. Compared to the genetic algorithm (GA), particle swarm optimization (PSO), and nonlinear least-square method (NLS), the Bayesian optimization (BO) performs best in identifying the structural damage and tension force.

A method of assisting small intestine capsule endoscopic lesion examination using artificial neural network (인공신경망을 이용한 소장 캡슐 내시경 병변 검사 보조 방법)

  • Wang, Tae-su;Kim, Minyoung;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.2-5
    • /
    • 2022
  • Human organs in the body have a complex structure, and in particular, the small intestine is about 7m long, so endoscopy is not easy and the risk of endoscopy is high. Currently, the test is performed with a capsule endoscope, and the test time is very long. The doctor connects the removed storage device to the computer to store the patient's capsule endoscope image and reads it using a program, but the capsule endoscope test results in a long image length, which takes a lot of time to read. In addition, in the case of the small intestine, there are many curves due to villi, so the occlusion area or light and shade of the image are clearly visible during the examination, and there may be cases where lesions and abnormal signs are missed during the examination. In this paper, we provide a method of assisting small intestine capsule endoscopic lesion examination using artificial neural networks to shorten the doctor's image reading time and improve diagnostic reliability.

  • PDF

Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing (3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작)

  • Yuntae Ha;JinBeom Kwon;Suji Choi;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

A study on the implementation of Korea's traditional pagoda WebXR service

  • Byong-Kwon Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.69-75
    • /
    • 2024
  • This study focuses on enhancing the understanding of the form and characteristics of traditional towers, or 'pagodas,' by utilizing WebXR technology to enable users to explore 3D models and experience them in virtual reality on the web. Traditional towers in Korea pose challenges for direct on-site verification due to their size, making it difficult to examine the structure and features of each level. To address these issues, this research aims to provide users with a WebXR service that allows them to remotely explore and analyze towers without geographical or temporal constraints. The research methodology involves utilizing WebAR to offer a web-based service where users can directly view the original form of the tower's 3D model using smart devices both online and on-site. However, outdoor conditions may affect performance, and to address this, a tower-outline detection and matching technique was employed. Consequently, we propose a remote support service for traditional towers, allowing users to remotely access information and features of various towers nationwide on the web. Meanwhile, on-site visits can involve experiencing augmented reality representations of towers using smart devices.

Comparative Analysis of DTM Generation Method for Stream Area Using UAV-Based LiDAR and SfM (여름철 UAV 기반 LiDAR, SfM을 이용한 하천 DTM 생성 기법 비교 분석)

  • Gou, Jaejun;Lee, Hyeokjin;Park, Jinseok;Jang, Seongju;Lee, Jonghyuk;Kim, Dongwoo;Song, Inhong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.3
    • /
    • pp.1-14
    • /
    • 2024
  • Gaining an accurate 3D stream geometry has become feasible with Unmanned Aerial Vehicle (UAV), which is crucial for better understanding stream hydrodynamic processes. The objective of this study was to investigate series of filters to remove stream vegetation and propose the best method for generating Digital Terrain Models (DTMs) using UAV-based point clouds. A stream reach approximately 500 m of the Bokha stream in Icheon city was selected as the study area. Point clouds were obtained in August 1st, 2023, using Phantom 4 multispectral and Zenmuse L1 for Structure from Motion (SfM) and Light Detection And Ranging (LiDAR) respectively. Three vegetation filters, two morphological filters, and six composite filters which combined vegetation and morphological filters were applied in this study. The Mean Absolute Error (MAE) and Root Mean Square Error (RMSE) were used to assess each filters comparing with the two cross-sections measured by leveling survey. The vegetation filters performed better in SfM, especially for short vegetation areas, while the morphological filters demonstrated superior performance on LiDAR, particularly for taller vegetation areas. Overall, the composite filters combining advantages of two types of filters performed better than single filter application. The best method was the combination of Progressive TIN (PTIN) and Color Indicies of Vegetation Extraction (CIVE) for SfM, showing the smallest MAE of 0.169 m. The proposed method in this study can be utilized for constructing DTMs of stream and thus contribute to improving the accuracy of stream hydrodynamic simulations.

Local/Global Structural Health Monitoring System Using Piezoelectric Sensors (압전센서를 이용한 구조물 국부/광역 손상 진단 시스템)

  • Kim, Byung-Soo;Kwon, Hyeok-Sang;Kim, Jin-Wook;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.308-317
    • /
    • 2009
  • In the present work, a sensor system composed of an oscillator sensor and a Lamb wave sensor is proposed for the purpose of structural health monitoring. The oscillator sensing system detecting the shift of a structural resonant frequency in proportion to the amount of defects in the structure is a pretty sensitive and simple device, but its detectable range is limited to its local zone. The Lamb wave sensor system, however, is applicable to global detection of the defects. This study is aimed at investigating the feasible combination of the two systems to exploits their merits simultaneously. The scheme to use PZT patches as the oscillator sensor as well as the Lamb wave sensor was proposed to identify the position, length and number of cracks by means of TOF and amplitude of signals, and its validity was confirmed through experiments.

Imaging Findings of an Intraluminal Duodenal Diverticulum Associated with Adult Duodeno-Duodenal Intussusception and Recurrent Pancreatitis: A Case Report (성인 십이지장-십이지장 장중첩증 및 재발성 췌장염과 관련된 관강내 십이지장 게실의 영상 소견: 증례 보고)

  • Ga Young Yi;Jeong Kyong Lee;Huisong Lee;Sun Young Yi;SangHui Park
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.680-686
    • /
    • 2022
  • Intraluminal duodenal diverticulum (IDD) is a rare congenital abnormality, consisting of a saclike mucosal lesion in the duodenum. Cases of IDD can present with gastrointestinal bleeding, duodenal obstruction, or pancreatitis. Here, we report a rare case of a 25-year-old female presenting with IDD complicated by duodeno-duodenal intussusception and recurrent pancreatitis. The diagnosis was based on findings from radiologic examinations (CT and MRI), upper gastrointestinal series (barium swallow), and gastroduodenofiberscopy. Laparoscopic excision of the presumed duodenal duplication was performed. The subsequent histopathologic evaluation of the excised sac revealed normal mucosa on both sides, but the absence of a proper muscle layer confirmed the diagnosis of IDD. Radiologic detection of a saccular structure in the second portion of the duodenum can indicate IDD with duodeno-duodenal intussusception as the lead point.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

Estimation for warfarin in pharmaceutical preparation using monolithic column

  • Zahraa Hadi Shareef;Ahmed Ali Alkarimi
    • Analytical Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.220-229
    • /
    • 2024
  • This study aims to developing a method for estimating pharmaceutical compounds within a monolith column using high-performance liquid chromatography (HPLC). The monolithic column was prepared using copolymerization of glycidyl methacrylate, co-ethylene dimethacrylate, and co-acrylic acid inside a borosilicate tube of specific dimensions a 60 mm borosilicate tube length with 1.5 mm and 3.5 mm inner and outer diameters, respectively. A UV Ultra violet source with a wavelength of 365 nm was used, and the polymerization process involved mixing glycidyl methacrylate, acrylic acid, ethylene dimethacrylate as a binder, and 2,2-dimethoxy-2-phenyl acetate phenone as an initiator in suitable solvents consisting of ethanol and 1-hexanol. The polymerization process formed the monolith column after 4 minutes, and subsequently, the epoxy groups were altered to diol groups using 0.2 M hydrochloric acid HCl, which were pumped through the column for 3 hours at a flow rate of 10 µL·min-1. Various techniques, such as Scanning Electron Microscope SEM, Brunauer-Emmett-Teller BET, Fourier-transform infrared spectroscopy FT-IR and HNMR, were utilized to characterize and confirm the structure of the monolith. The prepared monolith was employed to estimate and identify the pharmaceutical compound of warfarin using high-performance liquid chromatography HPLC. The analytical curve of warfarin was linear in the range of 3 to 100 ㎍·mL-1 with an r2 value of 0.999. The detection and quantification limits were 0.932 and 2.788 ㎍·mL-1, respectively. The molar absorptivity and Sandells sensitivity were 2.99138 × 106 L·mol-1·cm-1 and 103.1 × 10-3 ㎍·cm-2, respectively.