• 제목/요약/키워드: structure control

검색결과 9,603건 처리시간 0.05초

MFC를 이용한 손상된 복합재의 능동제어 (Active Control of Damaged Composite Structure Using MFC Actuator)

  • 손정우;김흥수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.535-540
    • /
    • 2013
  • In this work, active control algorithm is adopted to reduce delamination effects of the damaged composite structure and control performance with MFC actuator is numerically evaluated. Finite element model for the damaged composite structure with piezoelectric actuator is established based on improved layerwise theory. In order to achieve high control performance, MFC actuator, which has increased actuating force, is considered as a piezoelectric actuator. Mode shapes and corresponding natural frequencies for the damaged smart composite structure are studied. After design and implementation of active controller, dynamic characteristics of the damaged smart composite structure are investigated.

  • PDF

The actuation equation of macro-fiber composite coupled plate and its active control over the vibration of plate and shell

  • Tu, Jianwei;Zhang, Jiarui;Zhu, Qianying;Liu, Fan;Luo, Wei
    • Structural Monitoring and Maintenance
    • /
    • 제5권2호
    • /
    • pp.297-311
    • /
    • 2018
  • Plate and shell structure is widely applied in engineering, i.e. building roofs, aircraft wings, ship platforms, and satellite solar arrays. Its vibration problem has become increasingly prominent due to the tendency of lightening, upsizing and flexibility. As a new smart material with great actuating force and toughness, macro-fiber composite (MFC) is composed of piezoelectric fiber and epoxy resin basal body, which can be directly pasted onto the surface of plate and shell and is suitable for vibration control. This paper deduces the actuation equation of MFC coupled plate in different boundary conditions, an equivalent finite element modeling method is proposed which uses MFC actuating force as the applied excitation, and on this basis the active control simulation and experiment of MFC over plate and shell structure vibration are accomplished. The results indicate that MFC is able to implement effective control over plate and shell structure vibration in multi-band range. The comparison between experiment and simulation proves that the actuation equation deduced herein, effective and practicable, can be applied into the simulation calculation of MFC vibration control over plate and shell structure.

Research Progress of the Structure Vibration-Attitude Coordinated Control of Spacecraft

  • Yang, Jingyu;Qu, Shiying;Lin, Jiahui;Liu, Zhiqi;Cui, Xuanming;Wang, Chu;Zhang, Dujiang;gu, Mingcheng;Sun, Zhongrui;Yang, Kang;Zhou, Lanwei;Chen, Guoping
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권4호
    • /
    • pp.590-601
    • /
    • 2015
  • This paper gives an overview of research on the field of structure vibration-attitude coordinated control of spacecraft. First of all, the importance of the technology has been given an introduction, and then later the research progress of space structure dynamics modeling, research progress of structure vibration-attitude coordinated control of flexible spacecraft have been discussed respectively. Finally, future research on application of structure vibration-attitude coordinated control of spacecraft has been recommended.

정보기술구조유형이 경영성과에 미치는 영향 - 조직구조와 통제시스템의 조절효과를 중심으로 - (Influences of Information Technology Structure Taxonomy on Business Performance - Moderating Effect of Organization Structure and Control System -)

  • 김문식
    • Asia pacific journal of information systems
    • /
    • 제9권1호
    • /
    • pp.17-38
    • /
    • 1999
  • While the value of information technology has long been a hot issue, few solid results have been found as of yet. It is partly due to methodological factors and model underspecifcation. This study empirically develops a ITS(information technology structure) taxonomy and investigates the relationships between ITS taxonomy and business performance in the Korean firms. Among factors that impact business performance, organization structure and control system are selected and they are hypothesized to moderate-the relationships between ITS taxonomy and business performance. By surveying 91 manufacturing firms and applying hierarchical cluster analysis, four ITS are identified : centralized, decentralized, centralized cooperative, decentralized cooperative. ANOVA, correlation analysis and crosstable analysis say the presence of moderating effect of organization structure and control system. Cooperative ITS is best in business performance. Centralized ITS is related to functional organizational form. Decentralized ITS is related to product organizational form with decentralized decision making, Centralized cooperative ITS is related to matrix organizational form. Decentralized cooperative ITS is related to matrix organizational form with high integration. These findings have implications for the opportunities and challenges to match information technology with organization structure and control system.

  • PDF

Integration of health monitoring and vibration control for smart building structures with time-varying structural parameters and unknown excitations

  • Xu, Y.L.;Huang, Q.;Xia, Y.;Liu, H.J.
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.807-830
    • /
    • 2015
  • When a building structure requires both health monitoring system and vibration control system, integrating the two systems together will be cost-effective and beneficial for creating a smart building structure with its own sensors (nervous system), processors (brain system), and actuators (muscular system). This paper presents a real-time integrated procedure to demonstrate how health monitoring and vibration control can be integrated in real time to accurately identify time-varying structural parameters and unknown excitations on one hand, and to optimally mitigate excessive vibration of the building structure on the other hand. The basic equations for the identification of time-varying structural parameters and unknown excitations of a semi-active damper-controlled building structure are first presented. The basic equations for semi-active vibration control of the building structure with time-varying structural parameters and unknown excitations are then put forward. The numerical algorithm is finally followed to show how the identification and the control can be performed simultaneously. The results from the numerical investigation of an example building demonstrate that the proposed method is feasible and accurate.

Soil-structure interaction effect on active control of multi-story buildings under earthquake loads

  • Chen, Genda;Chen, Chaoqiang;Cheng, Franklin Y.
    • Structural Engineering and Mechanics
    • /
    • 제10권6호
    • /
    • pp.517-532
    • /
    • 2000
  • A direct output feedback control scheme was recently proposed by the authors for single-story building structures resting on flexible soil body. In this paper, the control scheme is extended to mitigate the seismic responses of multi-story buildings. Soil-structure interaction is taken into account in two parts: input at the soil-structure interface/foundation and control algorithm. The former reflects the effect on ground motions and is monitored in real time with accelerometers at foundation. The latter includes the effect on the dynamic characteristics of structures, which is formulated by modifying the classical linear quadratic regulator based on the fundamental mode shape of the soil-structure system. Numerical result on the study of a $\frac{1}{4}$-scale three-story structure, supported by a viscoelastic half-space of soil mass, have demonstrated that the proposed algorithm is robust and very effective in suppressing the earthquake-induced vibration in building structures even supported on a flexible soil mass. Parametric studies are performed to understand how soil damping and flexibility affect the effectiveness of active tendon control. The selection of weighting matrix and effect of soil property uncertainty are investigated in detail for practical applications.

개루프제어로 이송되는 공작기계 구조물의 동적 거동을 위한 유한 요소 해석 (Finite element analysis for dynamic behavior of a machine tool structure fed in open loop control)

  • 최진우;이태홍
    • 한국생산제조학회지
    • /
    • 제19권5호
    • /
    • pp.596-602
    • /
    • 2010
  • In this study, a fmite element model was developed for analysis of feeding a structure in open loop control The finite element analysis (FEA) can simulate dynamic behavior of the structure of a machine tool rapidly traveling with a screw feeding driving system. The feeding mechanism was implemented with screw element of the FEA tool used in this study. The procedure was developed for the dynamic transient FEA. First, motion parameters such as jerk and velocity were introduced for the structure to be fed in open loop control When its traveling distance was determined, set-points for the distance were generated based on the motion parameters. The set-points were applied to the FE model constructed for the traveling structure. The FEA was executed and evaluated. In this study, the FEA procedure was applied to the column of a machine tool and the dynamic behavior of the column was evaluated. The FEA helps in evaluation of the motion characteristics of a structure. The convergence time of the structure vibration posterior to feeding termination can be estimated and the stiffness of the flexible structure is also evaluated against jerk, and acceleration. It provides the feeding force which is helpful in selection of the feeding motor.

Smart modified repetitive-control design for nonlinear structure with tuned mass damper

  • ZY Chen;Ruei-Yuan Wang;Yahui Meng;Timothy Chen
    • Steel and Composite Structures
    • /
    • 제46권1호
    • /
    • pp.107-114
    • /
    • 2023
  • A new intelligent adaptive control scheme was proposed that combines observer disturbance-based adaptive control and fuzzy adaptive control for a composite structure with a mass-adjustable damper. The most important advantage is that the control structures do not need to know the uncertainty limits and the interference effect is eliminated. Three adjustable parameters in LMI are used to control the gain of the 2D fuzzy control. Binary performance indices with weighted matrices are constructed to separately evaluate validation and training performance using the revalidation learning function. Determining the appropriate weight matrix balances control and learning efficiency and prevents large gains in control. It is proved that the stability of the control system can be ensured by a linear matrix theory of equality based on Lyapunov's theory. Simulation results show that the multilevel simulation approach combines accuracy with high computational efficiency. The M-TMD system, by slightly reducing critical joint load amplitudes, can significantly improve the overall response of an uncontrolled structure.

다변수 가변구조 제어 시스템에서 시변 스위칭 초평면의 새로운 시도 (New Approach of Time-varying Switching Hyperplane in Multivariable Variable Structure Control Systems)

  • 이주장;김종준;김은선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.402-406
    • /
    • 1990
  • A new approach of a time-varying switching hyperplane based on the theory of variable structure system (VSS) is proposed for the control of multivariable systems. While the conventional switching surface can net achieve the robust performance against parameter variations and disturbances before the sliding mode occurs, the proposed switching hyperplane, which is obtained from the eigen-structure assignment theory powerfully used in the linear multivariable systems, ensures the sliding mode from the initial state. And new continuous control input which guarantees the sliding mode is proposed. This new control input does not arise chattering problem which arises with the conventional control input of variable structure control systems. Through numerical examples, the expellant performances of the proposed controller are verified.

  • PDF

의료용 CSF 제어 밸브 설계를 위한 유동/구조 상호작용 해석 (A Flow/structure Interaction Analysis for the Design of Medical CSF-Flow Control Valve)

  • 원찬식;허남건;이종선
    • 한국전산유체공학회지
    • /
    • 제6권1호
    • /
    • pp.40-46
    • /
    • 2001
  • Pressure-flow control characteristics of a commercially available cerebrospinal flow(CSF) control shunt valve was studied using flow/structure interaction analyses. Pre-stress of the valve diaphragm(membrane) was accounted for the simulation of an actual valve. The present results were in good agreement with the valve specification listed in the commercially available CSF control valve. The flow/structure interaction analysis of the present study can be effectively used to design a variety of CSF control shunt valves.

  • PDF