• 제목/요약/키워드: structural strength assessment

검색결과 355건 처리시간 0.026초

Influence of infill panels on an irregular RC building designed according to seismic codes

  • Ercolino, Marianna;Ricci, Paolo;Magliulo, Gennaro;Verderame, Gerardo M.
    • Earthquakes and Structures
    • /
    • 제10권2호
    • /
    • pp.261-291
    • /
    • 2016
  • This paper deals with the seismic assessment of a real RC frame building located in Italy, designed according to the current Italian seismic code. The first part of the paper deals with the calibration of the structural model of the investigated building. The results of an in-situ dynamic identification test are employed in a sensitivity and parametric study in order to find the best fit model in terms of frequencies and modal shapes. In the second part, the safety of the structure is evaluated by means of nonlinear static analyses, taking into account the results of the previous dynamic study. In order to investigate the influence of the infills on the seismic response of the structure, the nonlinear static analyses are performed both neglecting and taking into account the infill panels. The infill panels differently change the behavior of the structure in terms of strength and stiffness at different seismic intensity levels. The assessment study also verifies the absence of brittle failures in structural elements, which could be caused by either the local interaction with infills or the failure of the strength hierarchy.

Seismic performance analysis of steel-brace RC frame using topology optimization

  • Qiao, Shengfang;Liang, Huqing;Tang, Mengxiong;Wang, Wanying;Hu, Hesong
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.417-432
    • /
    • 2019
  • Seismic performance analysis of steel-brace reinforced concrete (RC) frame using topology optimization in highly seismic region was discussed in this research. Topology optimization based on truss-like material model was used, which was to minimum volume in full-stress method. Optimized bracing systems of low-rise, mid-rise and high-rise RC frames were established, and optimized bracing systems of substructure were also gained under different constraint conditions. Thereafter, different structure models based on optimized bracing systems were proposed and applied. Last, structural strength, structural stiffness, structural ductility, collapse resistant capacity, collapse probability and demolition probability were studied. Moreover, the brace buckling was discussed. The results show that bracing system of RC frame could be derived using topology optimization, and bracing system based on truss-like model could help to resolve numerical instabilities. Bracing system of topology optimization was more effective to enhance structural stiffness and strength, especially in mid-rise and high-rise frames. Moreover, bracing system of topology optimization contributes to increase collapse resistant capacity, as well as reduces collapse probability and accumulated demolition probability. However, brace buckling might weaken beneficial effects.

Investigation of performance of steel plate shear walls with partial plate-column connection (SPSW-PC)

  • Azandariani, Mojtaba Gorji;Gholhaki, Majid;Kafi, Mohammad Ali;Zirakian, Tadeh;Khan, Afrasyab;Abdolmaleki, Hamid;Shojaeifar, Hamid
    • Steel and Composite Structures
    • /
    • 제39권1호
    • /
    • pp.109-123
    • /
    • 2021
  • This research endeavor intends to use the implicit finite element method to investigate the structural response of steel shear walls with partial plate-column connection. To this end, comprehensive verification studies are initially performed by comparing the numerical predictions with several reported experimental results in order to demonstrate the reliability and accuracy of the implicit analysis method. Comparison is made between the hysteresis curves, failure modes, and base shear capacities predicted numerically using ABAQUS software and obtained/observed experimentally. Following the validation of the finite element analysis approach, the effects of partial plate-column connection on the strength and stiffness performances of steel shear wall systems with different web-plate slenderness and aspect ratios under monotonic loading are investigated through a parametric study. While removal of the connection between the web-plate and columns can be beneficial by decreasing the overall system demand on the vertical boundary members, based on the results and findings of this study such detachment can lower the stiffness and strength capacities of steel shear walls by about 25%, on average.

Partial-interaction fatigue assessment of stud shear connectors in composite bridge beams

  • Seracino, Rudolf;Oehlers, Deric J.;Yeo, Michael F.
    • Structural Engineering and Mechanics
    • /
    • 제13권4호
    • /
    • pp.455-464
    • /
    • 2002
  • There is a growing demand to assess the remaining strength and endurance of existing composite steel and concrete bridge beams due to the aging infrastructure, increases in permissible vehicle weights and increases in their frequencies. As codes are generally dedicated to the design of new structures, new procedures are required to aid in the assessment of existing bridges to ensure that they are utilised to the full. In this paper, simple expressions are presented to perform partial-interaction analyses directly from full-interaction analyses, so that the beneficial effect of partial-interaction on the shear forces on the shear connectors can be utilised in assessment to extend the fatigue life of simply supported bridge beams and to determine the effect of remedial work if necessary. Use of the assessment technique is described by way of an illustrative example.

Hull Strength Evaluation of Dissemination 12ft Bass Fishing Boat Using FEA (보급형 12피트 배스 낚시보트의 유한요소해석을 통한 선체강도평가)

  • Oh, Young-Cheol;Ko, Jae-Yong;Chung, Se-Yun;Choi, Jeong-Hwan;Kim, Hyeon-Jin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 한국항해항만학회 2012년도 춘계학술대회
    • /
    • pp.225-226
    • /
    • 2012
  • Recently, In the domestic is used mainly fiberglass reinforced plastic(GRP) and is built for maritime leisure vessel & structures. but it less attention is insufficient for ship of structural strength assessment of maritime leisure vessel. Therefore, The structural strength evaluation suitable for the domestic situation formulate and is applied to domestic regulations of "Guidance for Recreational Crafts" of Korea register of shipping(KR) & "Reinforced plastic line structure standards" of Ministry of Land, Transport and Maritime Affairs. the structural design and finite element analysis(FEA) to ensure the reliability.

  • PDF

The Evaluation of Strength for the Corner Block Structure in the LNG Tank using Sloshing Pressure of the Scaled Tank (모형수조 슬로싱 하중을 이용한 LNG 탱크 코너블럭(Corner Block) 구조물의 구조강도 평가)

  • Park, Jun Hyeong;Park, Si Jong;Kim, Seong Hoon;Choi, Jae Min;Jun, In Ki
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제26권5호
    • /
    • pp.327-333
    • /
    • 2013
  • The purpose of this study is to predict sloshing pressure of a actual tank by using measured pressure in scaled down tank and to evaluate with structural strength of LNG Corner Block. For this purpose, we performed sloshing analysis about 138K class tank by using Ansys CFX program, and were measured both average pressure and maximum peak pressure according to scaled tank ratio. Also, measured pressure was converted to pressure of the actual tank by Froude scale law, and we conducted the evaluation of structural strength about the conner block of actual size KC-1.

Strength Prediction Equations for High Strength Concrete by Schmidt Hammer Test (슈미트 해머 시험에 의한 고강도 콘크리트의 강도 추정식)

  • Kwon, Young-Wung;Park, Song-Chul;Kim, Min-Su
    • Journal of the Korea Concrete Institute
    • /
    • 제18권3호
    • /
    • pp.389-395
    • /
    • 2006
  • For the assessment of exsiting concrete structures, it is important to get the real strength of concrete. The load test or core test has many problems due to cost time, easiness, structural damage, and reliability and so on. Thus, various non-destructive test and statistical analysis techniques for strength assessment have been developed. As a result the real strength of concrete can be obtained by both direct and indirect test. In this study, a series of experimental tests of core strength and Schmidt hammer tests on 3, 7, 14, 28, 90, 180, 365, and 730 days' were done for predicting the compressive strength of high strength concrete with 65.0MPa of 28-days' strength. Each experimental results was analyzed by simple regression analysis. Then, reliability level and error rate between the proposed equations and the existing ones was examined. However, the application of the exsisting equations was inadequate to high strength concrete, because they were conducted under normal strength concrete. Therefore, the following compressive strength equations were proposed for predicting the compressive strength of high strength concrete by Schmidt hammer test. The proposed equations by Schmidt hammer test are as follows.

Reliability assessment of RC shear wall-frame buildings subjected to seismic loading

  • Tuken, Ahmet;Dahesh, Mohamed A.;Siddiqui, Nadeem A.
    • Computers and Concrete
    • /
    • 제20권6호
    • /
    • pp.719-729
    • /
    • 2017
  • A considerable research is available on the seismic response of Reinforced Concrete (RC) shear wall-frame buildings, but the studies on the reliability of such buildings, with the consideration of human error, are limited. In the present study, a detailed procedure for reliability assessment of RC shear wall-frame building subjected to earthquake loading against serviceability limit state is presented. Monte Carlo simulation was used for the reliability assessment. The procedure was implemented on a 10-story RC building to demonstrate that the shear walls improve the reliability substantially. The annual and life-time failure probabilities of the studied building were estimated by employing the information of the annual probability of earthquake occurrence and the design life of the building. A simple risk-based cost assessment procedure that relates both the structural life-time failure probability and the target reliability with the total cost of the building was then presented. The structural failure probability (i.e., the probability of exceeding the allowable drift) considering human errors was also studied. It was observed that human error in the estimation of total load and/or concrete strength changes the reliability sharply.

A Study on the Fatigue Strength Evaluation for Fillet Weldment including Stress Singularity using Structural Stress with Virtual Node Method (응력 특이점을 갖는 필릿 용접구조물의 피로해석을 위한 가상절점법을 이용한 구조응력 계산 기법 고찰)

  • Ha Chung-In;Kang Sung-Won;Kim Myung-Hyun;Kim Man-Soo;Sohn Sang-Yong;Heo Joo-Ho
    • Journal of Welding and Joining
    • /
    • 제24권3호
    • /
    • pp.27-33
    • /
    • 2006
  • Structural stress approach is well known as a mesh-size insensitive fatigue assessment method by using finite element analyses. It is, however, difficult to estimate the structural stress (SS) at weld end points due to stress singularities when shell elements are used. In this study, fatigue evaluations with longitudinal load carrying box fillet weldment under out-of-plane bending load have been performed by using virtual node method (VNM) in order to avoid the problem, which is called the weld end effect. Various combinations of virtual node parameters, such as reference point and virtual node locations, are investigated for the estimation of proper structural stress values applying VNM in a systematic manner. The appropriate guidance of virtual node parameter has been offered for the fillet weldment considered in the study. The structural stress values obtained by VNM have also been validated by comparing the result with finite element model including weld bead. Moreover, the fatigue strength of the fillet weldment based on the equivalent structural stress is shown to be consistent with the master S-N curve.

Integrity Evaluation of Agitating Axis and Blade in the Organic Waste Reactor (유기성 폐기물 반응기 내부 교반 축 및 블레이드 건전성 평가)

  • Yun, Yu Seong
    • Journal of the Korean Society of Safety
    • /
    • 제32권2호
    • /
    • pp.1-6
    • /
    • 2017
  • Modern society has been experiencing by population growth and urbanization that bring, a change of eating habits which has occurred a various types of waste in a large amount. Even though these wastes are required an immediate treatment with difficulties unsanitary handling and existing waste treatment method are by incineration, fermentation, drying and etc. however a bad smell occurs after the treatment that need's a lot of energy in processing organic wastes with high moisture contents and wasteful and inefficient problem. The strength assessment of the organic waste agitating vessel is required in terms of safety due to the differences of loading on the shaft that was treated by agitating the mixture of food waste. The damage of agitating axis is depended on steam pressure, temperature condition and the force moment that exerted by the food waste. Thus the strength assessment and stability evaluation are very important, especially to handle a hard waste. In this study the rotation capacity of agitation is about 5 tons considering general structural rolled steel pressure vessel strength and steam pressure. The purpose is to estimate the safety and strength evaluation for a agitator axis and impellers according to the rotating angle of the axis under the condition of the 3.2 ton capacity reactor.