• Title/Summary/Keyword: structural member behavior

Search Result 398, Processing Time 0.023 seconds

Improvement of Earthquake-Resistant Performance of R/C Beam-Column Joint Constructed with High-Strength Concrete Subjected to Cyclic Loading (고강도 철근콘크리트 보-기둥 접합부의 내진성능 개선에 관한 실험적 연구)

  • Ha, Gee-Joo;Kim, Jin-Keun;Chung, Lan
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.1
    • /
    • pp.135-145
    • /
    • 1992
  • With the increasing tendency to construct high rise reinforced concrete building~i, it is required to use high strength materIals, smaller member sections, and larger reinforcing bars, I t is generally recognized that under severe seismic loads beam column jomts may become more critical structural components than other structural elements. In a ductile momentresistmg reinforced concrete frame, the connection of bearncolumn must be capable of resistll1g the large lateral forces caused by seismic actions, The purpose of this experimental study is to evaluate and ll1vestigate the earthquake resistant perform ance of beam-colurrm subassemblies constructed with high-strength concrete cast by the concrete of com¬pressive strength of 700kg / cm2 subjected to reversed cyclic loadings. New approaches for moving the plastic hinging zone away from the column face and preventing the di¬agonal crack in the joint region are adopted to advance the earthquake-resistant performance of beam-column subassemblies using high-strengh concrete under severe earthquake-type loading. Exper¬imental results indicate that the modified new details which are introduced by intermediate reinforcement in the beam over a specific beam length adjacent to the joint are able to attain the stable hysteretic behavior and the enhancement of earthquake-resistant performance. Keywords: high strength concrete: beam-column Joints; seirnic loads(reversed cyclic loading) : earth¬quake-resistant performance; plastic hinge zone: diagonal crack: intermediate reinforce¬ment ; closed strirrup: hysteretic behavior: enhancement .

Study on the Variation of Energy Dissipation Factor of Reinforced Concrete Beam under Cyclic Loading (반복하중을 받는 철근콘크리트 보의 에너지소산계수 변화 특성 고찰)

  • Suk-Hyeong Yoo;Dae-Young Kang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.86-93
    • /
    • 2023
  • As the hysteretic behavior of reinforced concrete members under cyclic loading progresses, the energy dissipation ability decreases due to a decrease in stiffness and strength and pinching effects. However, the guideline "Nonlinear Analysis Model for Performance-Based Seismic Design of Reinforced Concrete Building Structures, 2021" requires calculating a single energy dissipation factor for each member and all histeric step, so the decrease in energy dissipation capacity according to histeric step cannot be considered. It is judged that Therefore, in this study, the energy dissipation factor according to the histeric step was examined by comparing the existing experimental results and the nonlinear time history analysis results for a general beam under cyclic loading. The energy dissipation factor was calculated as the ratio of the energy dissipation amount of the actual specimen to the energy dissipation amount of the idealized elastoplastic behavior obtained as a result of nonlinear time history analysis. In the existing experiment results, the energy dissipation factor was derived by calculating one cycle for each histeric step, and the energy dissipation factor was derived based on the nonlinear modeling process in the guidelines. In the existing experimental study, the energy dissipation factor was calculated by setting each histeric step (Y-L-R), and the energy dissipation factor was found to be 0.36 in the Y-L step and 0.28 in the L-R step, and the energy dissipation factor in the guideline was found to be 0.31. This shows that the energy dissipation factor calculation formula in the guidelines does not indicate a decrease in the energy dissipation capacity of reinforced concrete members.

Factors Affecting Members' Sense of Belonging in Virtual Community (가상커뮤니티에서의 구성원 소속감에 영향을 미치는 요인)

  • Lee, Kook-Yong
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.35 no.1
    • /
    • pp.19-45
    • /
    • 2010
  • Virtual Communities, which are formed on the Internet, are expected to serve the needs of members for e-collaboration, e-communication, information and knowledge sharing. The executives of organizations should consider virtual community as a new innovation or knowledge pool since members share knowledge. However, many virtual community have failed due to members' low willingness to engage and furthermore to share knowledge with other members. Thus, there is a need to understand and foster the determinants of members' sense of belonging behavior in virtual community. This study develops an integrated model designed to investigate and explain the relationships between contextual factors, personal perceptions of virtual community, usability, trust and sense of belonging in using a certain virtual community. Empirical data was collected from 201 and tested using structural equation modeling (SEM) to verify the fit of the hypothetical model. The results show that the perceived usability and community trust of members significantly influences sense of belonging in using the virtual community, and information quality, system quality, familiarity on the virtual community are significantly influence the usability but not reputation. And I confirmed that perceived shared vision and responsiveness play the role of determinants in making the member's trust, perceived risk influence the making community trust in directly. The results of the study can be used to identify the motivation underlying members' sense of belonging in a certain virtual community by investigating the impacts of contextual factors and personal perceptions on virtual community, the integrated model better explains behavior than other proposed models. This study might help executives of virtual communities and organizations to manage and promote these determinants of sense of belonging to stimulate members' willingness to engage the community and futhermore enhance their virtual community loyalty.

Study on the Cable Wall System Applied to Reinforced Concrete Exterior (철근콘크리트구조 외장재에 케이블월 시스템 적용에 관한 연구)

  • Park, Hyun-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.579-585
    • /
    • 2017
  • Development of a facade system that can reduce load factor and costs in high-rise building construction is required. The proposed cable wall system is used as a structural support by the glass-cable and can increase openness on lower elevations and the lobby area. Its use in high-rise buildings can reduce construction costs. Without transferring directly a strong initial tension of the cable to the building frame is connected to the steel member and the reinforced concrete structures, by absorbing the initial tension of the cable, it is possible to control the occurrence of a strong concentrated loads to the structure. Comparison of load-displacement test results from the numerical analysis with the test results showed reasonable agreement, Therefore, the proposed numerical results confirm good prediction of cable behavior for the facade system.

Experimental Study on Structural Behavior of Tapered non-compact Frame with Snug-tightened Conditions (밀착조임 볼트체결에 따른 판폭두께비가 큰 변단면 프레임의 구조성능에 관한 실험적 연구)

  • Chung, Kyung-Soo;Jeon, Bae-Ho;Park, Man-Woo;Do, Byung-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.257-265
    • /
    • 2012
  • Current trends in steel construction include using tapered, non-compact sections to minimize the use of excess material as much as possible by choosing the cross-sections instead of the classical approach of using prismatic members. In addition, snug conditions, especially the end-plate type, have the advantage of incurring less construction costs and shorter assembly times as opposed to full pre-tensioned conditions. On the other hand, it is important to predict the collapse of the PEB system due to over-loading. Large-scale tests of tapered steel portal frames with non-compact sections were conducted. The primary test parameters included the bolt connection method and the loading condition (vertical and horizontal load). The test results on initial stiffness and load capacity were investigated. Furthermore, comparisons between the analytical and experimental data for load-displacement curves were initiated. In addition, we evaluated the applicability of a snug bolt for the PEB frame in the field.

Fire Damaged Behavior of Real Sized Normal Strength RC Columns (화해를 입은 실물크기 보통강도 RC 기둥의 거동)

  • Lee, Cha-Don;Shin, Yeong-Soo;Hong, Sung-Gul;Lee, Kyung-Ku;Lee, Seung-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.866-876
    • /
    • 2003
  • Experiments were performed for the real sized 12 reinforced concrete columns of 350${\times}$350${\times}$3350 mm with normal concrete in order to observe the fire-damaged behavior of these columns. Columns were heated according to the ISO heating curve. Main experimental parameters were: magnitude of axial load, heating time, cover thickness, and eccentricity. Effects of these parameters on the axial expansion and contraction, rotation, buckling, ISO fire resistance, and structural stability were experimentally quantified. It has been observed that the contraction rate of axial deformation was affected mostly by the duration of heating time and buckling of reinforcement or member by the magnitude of axial load, duration of heating time, cover thickness and eccentricity in order. Based on the experimental observations, ISO fire resistance criteria were qualiatively criticized.

A Study on the Design Criteria Relating to the Local Buckling of Pultruded FRP Structural Compression Members (펄트루젼 구조압축재의 국부좌굴 설계규준 개발에 관한 연구)

  • Joo, Hyung Joong;Lee, Seung Sik;Yoon, Soon Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.597-606
    • /
    • 2006
  • Since FRP materials have various advantages over steel, many research activities to use them for the civil engineering applications are now in progress. The present paper deals with the local buckling behavior of FRP pultruded members as a first step toward the development of design criteria. In the design of compression members, it is very important to know not only if local buckling occurs or not but also which plate component governs local buckling, but it is not easy to perform this work in a rigorous manner. In the present paper, a simple and accurate equation which can compute the coefficients of buckling of orthotropic plates and local buckling of pultruded compression members is suggested by performing rigorous analysis, energy analysis, and parametric study. The local buckling strength and the plate component governing the local buckling behavior of thin-walled pultruded compression members can be easily determined by using the proposed equation.

Flexural and Tensile Performance of Strain-Hardening Cement Composite with Synthetic Fibers (합성섬유를 사용한 변형경화형 시멘트 복합체의 휨 및 인장성능)

  • Kim, Sun-Woo;Lee, Min-Jung;Jang, Yong-Heon;Jang, Gwang-Soo;Song, Seon-Hwa;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.925-928
    • /
    • 2008
  • Fiber is an important ingredient in strain-hardening cementitious composite (SHCC), which can control fracture of cementitious composite by bridging action. The properties of reinforcing fiber, as tensile strength, aspect ratio and elastic modulus, have great effect on the fracture behavior of SHCC. To apply SHCC to structural member, SHCC must have economical efficiency and workability as well as own excellent tensile performance. For these purposes, four-point bending and direct tensile tests on SHCC with only hybrid synthetic fibers, total fiber volume fraction, $V_f$, is 1.5%, are carried out. The research emphasis is on the mechanical properties of SHCC made in Polyvinyl alcohol (PVA) and Polyethylene (PE) fibers, and how this affects the composite property, and ultimately its strain-hardening performance. Also, effect of hybrid type and water-cement ratio on the behavior of SHCC was evaluated in this paper.

  • PDF

Numerical Study on Seismic Behavior of a Three-Story RC Shear Wall Structure (3층 전단벽 구조물의 지진응답에 관한 수치해석)

  • Park, Dawon;Choi, Youngjun;Hong, Jung-Wuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.111-119
    • /
    • 2021
  • A shear wall is a structural member designed to effectively resist in-plane lateral forces, such as strong winds and earthquakes. Due to its efficiency and stability, shear walls are often installed in residential buildings and essential facilities such as nuclear power plants. In this research, to predict the results of the shaking table test of the three-story shear wall RC structure hosted by the Korea Atomic Energy Research Institute, three types of numerical modeling techniques are proposed: Preliminary, Calibrated 1, and Calibrated 2 models, in order of improvement. For the proposed models, an earthquake of the 2016 Gyeongju, South Korea (peak ground acceleration of 0.28 g) and its amplified earthquake (peak ground acceleration of 0.50 g) are input. The response spectra of the measuring points are obtained by numerical analysis. Good agreement is observed in the comparisons between the experiment results and the simulation conducted on the finally adopted numerical model, Calibrated 2. In the process of improving the model, this paper investigates the influences of the mode shape, material properties, and boundary conditions on the structure's seismic behavior.

Unstable Behavior and Critical Buckling Load of a Single-Layer Dome using the Timber Elements (목재를 이용한 단층 지오데식 돔의 불안정 거동과 임계좌굴하중)

  • Hong, Seok-Ho;Ha, Hyeonju;Shon, Sudeok;Lee, Seungjae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.2
    • /
    • pp.19-28
    • /
    • 2023
  • Timber structures are susceptible to moisture, contamination, and pest infestation, which can compromise their integrity and pose a significant fire hazard. Despite these drawbacks, timber's lightweight properties, eco-friendliness, and alignment with current architectural trends emphasizing sustainability make it an attractive option for construction. Moreover, timber structures offer economic benefits and provide a natural aesthetic that regulates building temperature and humidity. In recent years, timber domes have gained popularity due to their high recyclability, lightness, and improved fire resistance. Researchers are exploring hybrid timber and steel domes to enhance stability and rigidity. However, shallow dome structures still face challenges related to structural instability. This study investigates stability problems associated with timber domes, the behavior of timber and steel hybrid domes, and the impact of timber member positioning on dome stability and critical load levels. The paper analyzes unstable buckling in single-layer lattice domes using an incremental analysis method. The critical buckling load of the domes is examined based on the arrangement of timber members in the inclined and horizontal directions. The analysis shows that nodal snapping is observed in the case of a concentrated load, whereas snap-back is also observed in the case of a uniform load. Furthermore, the use of inclined timber and horizontal steel members in the lattice dome design provides adequate stability.