• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.026 seconds

Evaluation of Effective Temperature for Estimate Design Thermal Loads in Steel Deck of Steel Box Girder Bridges (강상자형교의 강바닥판에서 설계온도하중을 위한 유효온도 산정)

  • Shin, Dong-Wook;Kim, Kyoung-Nam;Choi, Chul-Ho;Lee, Seong-Haeng
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.77-87
    • /
    • 2013
  • A present LSD (limited state design) code for temperature load in the domestic bridge design has applied a uniform standard for various bridge types. In this study, in order to calculate the effective temperature, a specimen of steel box girder bridge section with real size dimension was manufactured. For a year, the temperature data were measured at the 18 point in steel deck of steel box girder bridges specimen. Effective temperature within the cross section according to atmospheric temperature was calculated by this experiment data. The analyzed results were very similar correlation when compared with the effective temperature of the Euro Code. Therefore, the effective temperature which calculated based on the present data could be used as the basic data in order to present to the appropriate design criteria for the thermal loads on the domestic bridge design.

A Study on Experiment for Improvement of Water Quality in Concrete Block Using Illite and TiO2 Powder (일라이트와 이산화티탄을 활용한 콘크리트 블록의 수질환경개선을 위한 실험연구)

  • Her, Jae-Won;Kang, Kyung-Soo;Kim, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • In order to conduct the "A Study on Experiment for Improvement of Water Quality in Concrete Block Using illite and $TiO_2$ Powder", as a result of the preliminary mortar experiment, water quality purification characteristic test, pollution-resistance test, fish poison test, and the related KS-equivalent tests after manufacturing the actual concrete block, the following conclusion were deduced. As a result of the concrete block functional evaluation equivalent to KS, all the conditions showed higher compressive strength. Even though increase of absorption rate, according to illite replacement in vesicular structure, was expected as a problem, it was replaced after mixing with Titanium dioxide, and then Titanium dioxide was settled in large pores of illite so there was no problem in absorption rate.

Evaluation of Seismic Strengthening Approach at the Boundary Elements of RC Walls using Prestressed Wire Rope Units (프리스트레스트 와이어로프를 사용한 RC 벽체의 단부 경계요소 내진보강 평가)

  • Kwon, Hyuck-Jin;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.56-63
    • /
    • 2018
  • The present study examined the reversal cyclic flexural behavior of walls with jacket section approach for seismic strengthening through forming the boundary elements at both ends of the wall. The prestressed wire ropes were used for the lateral reinforcement to confine the boundary element of the wall. The main parameter investigated was the height of the jacket section for strengthening. The limit height of the strengthening jacket section was determined by comparing the moment distributions between the existing and strengthened walls. Test results showed that the examined jacket section approach was significantly effective in enhancing the flexural resistance of walls, indicating 46% higher stiffness at peak strength and 210% greater work damage indicator, compared with the flexural performance of the unstrengthened wall. The ductility of the strengthened walls was insignificantly affected by the height of the jacket section when the height is greater than twice the wall length. The flexural capacity of the strengthened walls was 22% higher than the predictions obtained using the equivalent stress block specified in ACI 318-14.

Evaluation of the Effect of Coupler on the Ductility of Rebar by Uniaxial Tensile Test (1축 인장시험을 통한 커플러가 철근 연성도에 미치는 영향 평가)

  • Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan;Jung, Chi-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.90-98
    • /
    • 2018
  • Recently, various reinforced concrete joints have been used in reinforced concrete structures. Therefore, it is important to grasp the tensile properties of the spliced rebar. In this study, uniaxial tensile tests were conducted on Grade 60 D22(#7), D29(#9), and two kinds of couplers manufactured according to ASTM A615 standard for evaluating ductility of coupler joints. The strain was measured using an image processing method more accurate and capable of measuring at various points freely. As the result of uniaxial tensile test, it was possible to calculate the stress-strain relationship and the longitudinal strain distribution according to the stress stages and it was founded that the average strain becomes lower as more occupying the coupler joint portions in the same gauge length. In addition, the empirical equations are proposed to account for the effect of the length of the coupler on the ultimate strain and the rupture strain.

Probabilistic Analysis of Repairing Cost Considering Random Variables of Durability Design Parameters for Chloride Attack (염해-내구성 설계 변수에 변동성에 따른 확률론적 보수비용 산정 분석)

  • Lee, Han-Seung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.32-39
    • /
    • 2018
  • Repairing timing and the extended service life with repairing are very important for cost estimation during operation. Conventionally used model for repair cost shows a step-shaped cost elevation without consideration of variability of extended service life due to repairing. In the work, RC(Reinforced Concrete) Column is considered for probabilistic evaluation of repairing number and cost. Two mix proportions are prepared and chloride behavior is evaluated with quantitative exterior conditions. The repairing frequency and cost are investigated with varying service life and the extended service life with repairing which were derived from the chloride behavior analysis. The effect of COV(Coefficient of Variation) on repairing frequency is small but the 1st repairing timing is shown to be major parameter. The probabilistic model for repairing cost is capable of reducing the number of repairing with changing the intended service life unlike deterministic model of repairing cost since it can provide continuous repair cost with time.

Shear Resistance Evaluation of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 전단내력 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.5290-5298
    • /
    • 2013
  • In order to apply a mechanical deck joint to the prefabricated steel grid composite decks, shear resistance of a joint composed of concrete shear key and high-tension bolt is experimentally evaluated by the push-out test. Shear resistance evaluated by the test is compared with resistance estimated by empirical and design equations based on the shear friction theory. Test results show that joint specimens bonded by epoxy have about 10% more shear resistance than specimens with strengthened shear key by steel plates, but in the case of specimens with strengthened shear key there is smaller resistance deviation than specimens bonded by epoxy. In comparison with resistances estimated by empirical and design equations, the deck joint can be safely designed. But because the existed shear resistance of deck joint is underestimated by the ACI-318, application of the LRFD design equation could be more reasonable.

Condition Evaluation of Bare Concrete Bridge Decks (콘크리트 노출 교량 바닥판의 상태평가 기법)

  • Suh, Jin-Won;Rhee, JI-Young;Seo, Sang-Gil;Shin, Jae-In
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.217-224
    • /
    • 2004
  • In 1980's, the concrete bridge decks were constructed with 4cm wearing surface layer instead of asphalt concrete overlays. After about 15 year service periods, deteriorations were appeared on the surfaces of highway bridge decks. Various field NDTs and lab tests were done to analysis the cause of the deterioration on the concrete deck surface. The main cause was the corrosion of rebars with thinner concrete top cover than the design value. The rebars with thinner concrete top cover was earlier corroded by penetrated chloride ions. If the appropriate top cover could be achieved, the bare concrete bridge decks can be used without earlier deteriorations.

Evaluation on Sulfate Attack for Concrete Structures of Nuclear Power Plants (원자력발전소 콘크리트 구조물의 황산염 침식 평가)

  • Lee, Jong-Suk;Moon, Han-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.169-176
    • /
    • 2004
  • The Mechanistic model, considering expansion stress, coefficient of diffusion etc. to time, is applied to predict the deterioration of concrete structures of the nuclear power plant(NPP) due to sulfate attack. Mix design for the test was three kinds of specified compressive strength 385, 280 and $210kgf/cm^2$ which are used to construct NPPs and cement was type I and V. The immersion test was performed with 10% $Na_2SO_4$ solution to cement type and strength for a year. The coefficient of diffusion on each concrete mix is calculated based on the results of immersion test, and it is used for predicting the sulfate attack of the concrete structures of NPP. The coefficient of diffusion of the target concrete ranged $0.5763{\sim}3.9002{\times}10^{-12}m^2/sec.$, and the sulfate attack rate of concrete structures of the NPP was predicted as 0.1~7.1 mm/year.

Girder Distribution Factors for Continuous Steel Girder Bridges (강거더 연속교의 횡방향 활하중분배계수 검증)

  • Eom, Jun-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.151-160
    • /
    • 2005
  • Current bridge design codes do not clearly specify the girder distribution factors for continuous bridges. The objective of the paper is to validate the use of code-specified girder distribution factors for the continuous steel girder bridges, and to provide a basis for recommended girder distribution factors (GDF) for interior girders, suitable for evaluation of existing continuous steel girder bridges. This paper presents the procedure and results of 3-dimensional finite element analysis that were performed on five of continuous steel girder bridges to verify girder distribution factors. The analysis results showed that the live load moment distribution at the negative moment region is very similar to those at the positive moment region in continuous steel girder bridges. It was also found that the GDF's based on the strain values are similar to those based on the deflection. GDF's based on the deflection show marginally better distribution. The analysis results confirmed that the code specified GDF's for continuous steel girder birdges are very conservative.

Evaluation of Nominal Flexural Strength in RC Beams Strengthend with CFRP Plate and Failed by Intermediate Crack Debonding (중간부 부착파괴된 CFRP 판 보강 RC 보의 휨강도 평가)

  • Hong, Sung Nam;Park, Jong In;Kim, Tae Wan;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.101-112
    • /
    • 2011
  • This paper shows a study carried out on the estimation of nominal flexural strength for CFRP-plated RC beams failed by intermediate crack debonding. A strength reduction factor is proposed to consider the effect of the intermediate crack debonding for the determination of nominal flexural strength. The proposed factor is derived from experimental data and utilizes the ratio of effective stress(or strain) in the CFRP plate to its ultimate strength(or strain) which is called effective strain model. An analytical equation for the estimation of the nominal flexural strength is formulated as a function of strength reduction factor. The validity, accuracy and efficiency of the proposed factor are established by comparing the analytical results with the experimental data, and the major design codes, as well as a number of factors given by researchers. The analytical results presented in this paper indicate that the proposed factor can effectively estimate the flexural nominal strength of CFRP-plated reinforced concrete beams failed by intermediate crack debonding.