• Title/Summary/Keyword: structural evaluation

Search Result 4,837, Processing Time 0.029 seconds

Feasibility study of wide-band low-profile ultrasonic sensor with flexible piezoelectric paint

  • Li, Xin;Zhang, Yunfeng
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.565-582
    • /
    • 2008
  • This paper presents a feasibility study of flexible piezoelectric paint for use in wide-band low-profile surface-mount or embeddable ultrasonic sensor for in situ structural health monitoring. Piezoelectric paint is a piezoelectric composite with 0-3 connectivity. Because of its ease of application, piezoelectric paint can be readily fabricated into sensing element with complex pattern. This study examines the characteristics of piezoelectric paint in acoustic emission signal and ultrasonic guided wave sensing. A series of ultrasonic tests including pitch catch and pencil break tests were performed to validate the ultrasonic wave sensing capability of piezoelectric paint. The results of finite element simulation of ultrasonic wave propagation, and acoustic emission generated by a pencil lead break on an aluminum plate are also presented in this paper along with corresponding experimental data. Based on the preliminary experimental results, the piezoelectric paint appears to offer a promising sensing material for use in real-time monitoring of crack initiation and propagation in both metallic and composite structures.

A method to evaluate the risk-based robustness index in blast-influenced structures

  • Abdollahzadeh, Gholamreza;Faghihmaleki, Hadi
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.47-54
    • /
    • 2017
  • Introduction of robustness index in the structure is done in three ways: deterministic robustness index, probabilistic robustness index, and risk-based robustness index. In past decades, there have been numerous researches to evaluate robustness index in both deterministic and probabilistic ways. In this research, by using a risk analysis, a risk-based robustness index has been defined for the structure. By creating scenarios in accordance with uncertainty parameters of critical and unexpected gas blast accident, a new method has been suggested for evaluating risk-based robustness index. Finally, a numerical example for the evaluation of risk-based robustness index of a four-storey reinforced concrete moment frame, designed and built based on Eurocode 8 code, has been presented with results showing a lower risk of robustness.

Pushover analysis - result borders due to hinge formation orders

  • Kulkarni, Supriya R.;Narayan, K.S. Babu
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.173-187
    • /
    • 2018
  • Performance evaluation of RC frame building by nonlinear static pushover analysis that accounts for elastic and post elastic behavior is becoming very popular as a valid decision making tool in seismic hazard resistant designs. Available literature suggests great amount of interest has shown by researchers in suggesting refinements to geometric and material modelling to bridge the gap between analytical predictions and observed performances. Notwithstanding the attempts gaps still exists. Sequence of plastic hinge formation which has great influence on pushover analysis results is an area less investigated. This paper attempts to highlight the importance of hinge sequence considerations to make analysis results more meaningful. Variation in analysis results due to different hinge sequences have been quantified, compared and bounds on analysis results have been presented.

Structural Evaluation of Glass-fiber Reinforced 3-Layer Polymer Composite Pipe (GFRP 보강 폴리머 모르터 3중복합관의 구조적 특성)

  • Yeon, Kyu-Seok;Kwon, Yoon-Hwan;Ryu, Keun-Woo;Jin, Nan-Ji
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.147-151
    • /
    • 2001
  • This study was performed to evaluate the internal and external factors affecting external strength of the 3-layer polymer composite pipes made of polymer mortar and fiber-glass reinforced plastic. Twenty four sandwich type 3-layer polymer composite pipes were made of polymer mortar and fiber-glass reinforced plastic by centrifugal method. The objective of this study was to evaluate the effects the of polymer mortar thickness for and core fiber-glass contents per unit area on external strength of 3-layer polymer composite pipes. For the more economical and practical design of 3-layer polymer composite pipe, further study should be done for the various polymer mortar, fiber-glass and different ratio of the inside/outside FRP thickness.

  • PDF

The Evaluation of Dielectric Capability in 22.9[kV] XLPE Insulated Cables (22.9[kV] XLPE 케이블의 절연성능평가)

  • 김충배;장동환;임장섭;한재홍;김상준;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.81-84
    • /
    • 1998
  • New diagnostic techniques have been tried on the applications of chemical, physical and micro-structural methods because there was a limit to diagnose degradation in Korean Underground Residential Distribution (URD) power cables with the conventional electrical methods. In this study, non-electrical properties were carried out as such. Characterization of interface layer was analyzed by X-ray, characterization of insulator by water tree, degree of crosslinking, shrinkage as well as ${\mu}$ -FTIR, characterization of semiconductive layer by volume resistivity. Electrical properties were also performed by leakage current.

  • PDF

Repair of Offshore Structures by Underwater Wet Welding Design and Fatigue Assessment

  • Krohn, A.;Petershagen, H.;Pohl, R.;Szelagowski, P.;Lafaye, G
    • Journal of Ship and Ocean Technology
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 1997
  • Under water wet welding is an economically alternative for the repair of offshore structures. In this paper investigations on the fatigue strength of a wet welded pipe structural member have been reported. For the connection a special sleeve patch design has been developed. The joint was fatigue tested. The evaluation of the test was carried out by means of the hot-spot approach with regard to several extrapolation rules of the hot-spot stress. Obtained results have been compared to actual classfication rules and recommendations.

  • PDF

Evaluation of Settling Characteristics at Lamellar Secondary Clarifier (Lamellar 이차침전지에서의 침강 특성 파악)

  • Lee, Byong-Hi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.471-478
    • /
    • 2012
  • Where an activated sludge system needs to be converted to biological nutrient removal(BNR) system, the secondary clarifier must handle higher MLSS from bioreactor since nitrification in BNR system that requires higher SRTs than activated sludge system. Either increase the clarifier size or modification of clarifier physical structure is required to cope with MLSS surge. One of recommended structural modification is the insertion of Lamellar within clarifier. In this study, two clarifiers - one has Lamellar structure inserted and the other does not - were used to compare the effect of Lamellar in solid/liquid separation. Same MLSS was fed to both clarifiers and concentrations of MLSS were varied. With all MLSS concentrations, attachment of MLSS on Lamellar was observed and it was found that detached MLSS caused the higher effluent SS concentrations than that of non-Lamellar clarifier effluent. From these results, Lamellar should not be inserted in clarifier to handle MLSS from BNR processes and the recommendation must be withdrawn.

Long run ambient noise recording for a masonry medieval tower

  • Casciati, S.;Tento, A.;Marcellini, A.;Daminelli, R.
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.367-376
    • /
    • 2014
  • Ambient vibration techniques are nowadays a very popular tool to assess dynamic properties of buildings. Due to its non destructive character, this method is particularly valuable, especially for health monitoring of historical monuments. The present ambient vibration experiment consists on the evaluation of vibration modes of a Medieval tower. Situated in Soncino (close to Cremona, in the Northern Italian region named Lombardia), the tower of 41.5 meters height has been monitored by seismometers located at different points inside the structure. Spectral ratios of the recorded ambient vibrations clearly identify a fundamental mode at about 1 Hz, with a slight difference in the two horizontal components. A second mode is also evidenced at approx 4-5 Hz, with a moderate degree of uncertainty. The records of a ML 4.4 earthquake, occurred during the monitoring period, confirm the information obtained by microtremor analysis. Daily variations of both 1st and 2nd mode were detected: these variations, of an amount up to 2%, seem to be well related with the temperature.

Autologous blood injection to the temporomandibular joint: magnetic resonance imaging findings

  • Candirli, Celal;Yuce, Serdar;Cavus, Umut Yucel;Akin, Kayihan;Cakir, Banu
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.13-18
    • /
    • 2012
  • Purpose : The aim of this study was to investigate the effect of the autologous blood injection (ABI) for chronic recurrent temporomandibular joint (TMJ) dislocation using magnetic resonance imaging (MRI). Materials and Methods : ABI was applied to 14 patients who had chronic recurrent TMJ dislocation. MRIs of the patients were taken and compared before and one month after the injection. Results : All of the patients had no dislocations of their TMJs on clinical examination one month after the injection. In the pre-injection, unilateral or bilateral TMJ dislocations were observed on MRIs in all patients. One month after the injection, TMJ dislocations were not observed in MRI evaluation of any patients. A significant structural change that caused by ABI was not observed. Conclusion : The procedure was easy to perform and it caused no foreign body reaction. However, it was unclear how the procedure prevented the dislocation.

Seismic Evaluation of Face-Loaded Unreinforced Masonry Walls (URM) (면외하중에 대한 비보강 조적벽의 내진성능 평가)

  • 유은진;이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.04a
    • /
    • pp.304-311
    • /
    • 2001
  • Unreinforced masonry is widely used as a structural material in residential constructions and known to have poor seismic performance in the out-of-plane rather than in-plane behavior. In countries of lower seismicity such as Korea, it is necessary to check the possibility of the mode of the out-of-plane failure. Though face loading is a major cause of the failure of masonary walls, Korean Seismic Code does not include provision for face-loaded unreinforced masonry walls. This paper briefly reviews the concept of analysis for unreinforced masonry walls subjected to face-load excitation proposed by Priestley, and its applicatility to Korean case.

  • PDF