• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.033 seconds

Structural identification of gravity-type caisson structure via vibration feature analysis

  • Lee, So-Young;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.259-281
    • /
    • 2015
  • In this study, a structural identification method is proposed to assess the integrity of gravity-type caisson structures by analyzing vibration features. To achieve the objective, the following approaches are implemented. Firstly, a simplified structural model with a few degrees-of-freedom (DOFs) is formulated to represent the gravity-type caisson structure that corresponds to the sensors' DOFs. Secondly, a structural identification algorithm based on the use of vibration characteristics of the limited DOFs is formulated to fine-tune stiffness and damping parameters of the structural model. Finally, experimental evaluation is performed on a lab-scaled gravity-type caisson structure in a 2-D wave flume. For three structural states including an undamaged reference, a water-level change case, and a foundation-damage case, their corresponding structural integrities are assessed by identifying structural parameters of the three states by fine-tuning frequency response functions, natural frequencies and damping factors.

Locating and identifying model-free structural nonlinearities and systems using incomplete measured structural responses

  • Liu, Lijun;Lei, Ying;He, Mingyu
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.409-424
    • /
    • 2015
  • Structural nonlinearity is a common phenomenon encountered in engineering structures under severe dynamic loading. It is necessary to localize and identify structural nonlinearities using structural dynamic measurements for damage detection and performance evaluation of structures. However, identification of nonlinear structural systems is a difficult task, especially when proper mathematical models for structural nonlinear behaviors are not available. In prior studies on nonparametric identification of nonlinear structures, the locations of structural nonlinearities are usually assumed known and all structural responses are measured. In this paper, an identification algorithm is proposed for locating and identifying model-free structural nonlinearities and systems using incomplete measurements of structural responses. First, equivalent linear structural systems are established and identified by the extended Kalman filter (EKF). The locations of structural nonlinearities are identified. Then, the model-free structural nonlinear restoring forces are approximated by power series polynomial models. The unscented Kalman filter (UKF) is utilized to identify structural nonlinear restoring forces and structural systems. Both numerical simulation examples and experimental test of a multi-story shear building with a MR damper are used to validate the proposed algorithm.

Hull Strength Evaluation of Dissemination 12ft Bass Fishing Boat Using FEA (보급형 12피트 배스 낚시보트의 유한요소해석을 통한 선체강도평가)

  • Oh, Young-Cheol;Ko, Jae-Yong;Chung, Se-Yun;Choi, Jeong-Hwan;Kim, Hyeon-Jin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.225-226
    • /
    • 2012
  • Recently, In the domestic is used mainly fiberglass reinforced plastic(GRP) and is built for maritime leisure vessel & structures. but it less attention is insufficient for ship of structural strength assessment of maritime leisure vessel. Therefore, The structural strength evaluation suitable for the domestic situation formulate and is applied to domestic regulations of "Guidance for Recreational Crafts" of Korea register of shipping(KR) & "Reinforced plastic line structure standards" of Ministry of Land, Transport and Maritime Affairs. the structural design and finite element analysis(FEA) to ensure the reliability.

  • PDF

A Study on Structural Safety Evaluation of let Vane under very High Temperature and Dynamic Pressure (초고온 동압을 밭는 제트 베인의 구조 안전성 평가에 대한 연구)

  • Park Sunghan;Lee Sangyeon;Park Jongkyoo;Kim Wonhoon;Moon Soonil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.18-24
    • /
    • 2005
  • To evaluate structural safety factor of the jet vane for the thrust deflection system under the dynamic pressure and very high temperature(2700$^{\circ}C$ ) of the combustion gas flow, the high temperature tension tests of refractory metals and 3-D nonlinear numerical simulations are performed. Through the analysis of high temperature structure behavior for jet vane, the structure safety of jet vane is evaluated, and numerical results are compared with static ground tests of jet vanes. It has been found that most of structural and thermal loading is concentrated on the vane shaft which worked as safe under 1400$^{\circ}C$. From the comparison of static ground tests and numerical results, the evaluation criterion using the vane load and shaft displacement is more useful to estimate the structural safety than using the equivalent stress.

A Study on the Development of the Structural Performance Evaluation Manual of the Skyscrapers Curtain Wall Systems for Construction Managers (초고층건축 알루미늄커튼월 구조설계검토 프로세스와 매뉴얼 개발에 관한 연구: 멀리언과 트랜섬을 중심으로)

  • Cho, Ye-Won;Lee, Min-Cheol;Ock, Jong-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.3
    • /
    • pp.92-101
    • /
    • 2009
  • The purpose of this study was to develop the curtain-wall structure design evaluation manual that can easily examine the curtain-wall structural members (Mullion and Transom) stability from the position of the construction managers. Through analyzing the structural design reports in the previous studies and interview with industry experts, the curtain-wall structural member design process was elicited. The manual, which consists of Microsoft Excel-based work sheet and its manual, was applied to a real curtain-wall design project to make sure its usability. A workshop with three curtain-wall experts and three construction managers was conducted to identify pros and cons of the manual, thereby enhancing its applicability in the future.

Evaluation of Progressive Collapse Resistance of Steel Moment Frame with WUF-B Connection and Composite Slab using Equivalent Energy-based Static Analysis (WUF-B 접합부 및 합성슬래브로 설계된 철골모멘트골조의 에너지 기반 근사해석을 이용한 연쇄붕괴 저항성능 평가)

  • Noh, Sam-Young;Park, Ki-Hwan;Hong, Seong-Cheol;Lee, Sang-Yun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.19-28
    • /
    • 2018
  • The progressive collapse resistance performance of a steel structure constructed using the moment frame with the WUF-B connection and the composite slabs was evaluated. GSA 2003 was adapted for the evaluation. Additionally the structural robustness and the sensitivity against the progressive collapse were analyzed. In the numerical analysis, a reduced model comprised of the beam and spring elements for WUF-B connection was adapted. The composite slab was modeled using the composite-shell element. Instead of the time-consuming dynamic analysis for the effect of the sudden column removal, the equivalent energy-based static analysis was effectively applied. The analysis results showed that the structure was the most vulnerable to in the case of the internal column removal, however it satisfied the chord rotation criterion of GSA 2003 due to the contribution of the composite slab which improved the stiffness of structure. In the robustness evaluation, the structural performance showed more than 2.5 times of the requirement according to GSA 2003, and the structural sensitivity analysis indicated the decrease of 33% of the initial structural performance.

The Design of Initial Member Sections and the Evaluation of Seismic Performance for Architectural Steel Structures with Brace Hysteretic Dampers (내진 댐퍼 브레이스를 가진 건축 강구조물의 초기 분재단면 설계 및 내진성능 평가)

  • Lee Sang-Ju;Lee Dong-Woo;Yang Jae-Guen;Han Sang-Eul
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.619-627
    • /
    • 2005
  • An initial member sections of steel structures is selected by experience of expert building structural designers. And appropriate member section is designed by repeat calculation through structural analysis. Therefore an initial assumption of member section is necessary for saving the time for structural design and is important to acquire safety of building structures. Also brace damper are generally used to prevent or decrease structural damage by its hysteretic behavior in building structures subjected to strong earthquake. Based on plastic design, the initial section of members for architectural steel structures with brace hysteretic dampers is presented and seismic effect of structural behavior by the ratio of damper stiffness to structural story stiffness is estimated in this paper.

  • PDF

Evaluation of one component structural sealant for curtain wall. (커튼월용 1액형 구조용 실란트 물성 평가 연구)

  • Han, Chang-Hwa;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.228-229
    • /
    • 2014
  • Recently, to ensure the high openness and prospect right of the building, curtain wall system is mainly applied to the high-rise buildings at domestic and overseas. As a result, the use of Structural Sealant is increasing. Structural Glazing Sealant is applied with the glass and AL-FRAME (Mullion) that the strong structural strength is required to hold. However, the structural sealant at the construction site in a variety of external influences, such as wind load, thermal load, uv, chemical pollutants etc, in case of storing condition, if structural sealant stored in high temperature for a long period time, it will not perform well compared with initial performance. In this study, the influence of the performance of one-component structural sealant evaluated for proper storage conditions at the construction site and how to use the non-intended.

  • PDF

Incorporating mesh-insensitive structural stress into the fatigue assessment procedure of common structural rules for bulk carriers

  • Kim, Seong-Min;Kim, Myung-Hyun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.1
    • /
    • pp.10-24
    • /
    • 2015
  • This study introduces a fatigue assessment procedure using mesh-insensitive structural stress method based on the Common Structural Rules for Bulk Carriers by considering important factors, such as mean stress and thickness effects. The fatigue assessment result of mesh-insensitive structural stress method have been compared with CSR procedure based on equivalent notch stress at major hot spot points in the area near the ballast hold for a 180 K bulk carrier. The possibility of implementing mesh-insensitive structural stress method in the fatigue assessment procedure for ship structures is discussed.

Evaluation of Underwater-Curing Coating Materials

  • Nah, Hwan-Seon;Kim, Kang-Seok;Kim, Kang-Sik;Lee, Chul-Woo;Baker, Randy
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.68-73
    • /
    • 2009
  • An evaluation of underwater - repair coating materials was based on the premise that defective areas of the existent epoxy coating such as blistering and cracking will be repaired on spot under submerged condition. Tests include the clarification as to whether they are compatible between as-built coating and new repair coating on each concrete specimen. Candidate coating materials for repair were tested in a laboratory to scrutinize their suitability to perform the needed function satisfactorily. The qualification tests performed are as a minimum as follows: Integrated radiation tolerance test, chemical resistance test (submerged condition in deionized water), hardness test and adhesion test of the repair materials. The proper repair coating materials were selected and approved from this test results.