• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.031 seconds

Correlation of Experimental and Analytical Inelastic Responses of A 1:12 Scale 10-Story Reinforced Concrete Frame-Wall Structure (1:12축소 10층 철근콘크리트 골조-벽식 구조의 비선형 거동에 대한 실험과 해석의 상관성)

  • 이한선;김상호
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.119-126
    • /
    • 2000
  • Reinforced concrete structural walls are widely known to provide an efficient lateral load resistance and drift control. However, many reported researches on them are mostly limited to the RC structural walls reinforced according to seismic details. When the pushover analysis technique is used for the prediction of inelastic behavior of frame-wall structures for the seismic evaluation of existing buildings having non-seismic details, the reliability of this analysis method should be checked by the test results. The objective of this study is to verify the correlation between the experimental and analytical responses of a high-rise reinforced concrete frame-wall structure having non-seismic details by using DRAIN-2DX program[11] and the test results performed previously[1]. It is concluded that the behavior of the frame-wall model is mainly affected by the fixed-end rotation(uplift at base) and bending deformation of the wall and that the analysis with the LINKS model[10] in DRAIN-2DX describes them with good reliability.

Evaluation of mechanical properties for high strength and ultrahigh strength concretes

  • Murthy, A. Ramachandra;Iyer, Nagesh R.;Prasad, B.K. Raghu
    • Advances in concrete construction
    • /
    • v.1 no.4
    • /
    • pp.341-358
    • /
    • 2013
  • Due to fast growth in urbanisation, a highly developed infrastructure is essential for economic growth and prosperity. One of the major problems is to preserve, maintain, and retrofit these structures. To meet the requirements of construction industry, the basic information on all the mechanical properties of various concretes is essential. This paper presents the details of development of various concretes, namely, normal strength concrete (around 50 MPa), high strength concrete (around 85 MPa) and ultra high strength concrete (UHSC) (around 120 MPa) including their mechanical properties. The various mechanical properties such as compressive strength, split tensile strength, modulus of elasticity, fracture energy and tensile stress vs crack width have been obtained from the respective test results. It is observed from the studies that a higher value of compressive strength, split tensile strength and fracture energy is achieved in the case of UHSC, which can be attributed to the contribution at different scales viz., at the meso scale due to the fibers and at the micro scale due to the close packing of grains which is on account of good grading of the particles. Micro structure of UHSC mix has been examined for various magnifications to identify the pores if any present in the mix. Brief note on characteristic length and brittleness number has been given.

Evaluation of the effect of smart façade systems in reducing dynamic response of structures subjected to seismic loads

  • Samali, Bijan;Abtahi, Pouya
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.983-1000
    • /
    • 2016
  • To date the engineering community has seen facade systems as non-structural elements with high aesthetic value and a barrier between the outdoor and indoor environments. The role of facades in energy use in a building has also been recognized and the industry is also witnessing the emergence of many energy efficient facade systems. This paper will focus on using exterior skin of the double skin facade system as a dissipative movable element during earthquake excitation. The main aim of this study is to investigate the potential of the facade system to act as a damper system to reduce earthquake-induced vibration of the primary structure. Unlike traditional mass dampers, which are usually placed at the top level of structures, the movable/smart double skin facade systems are distributed throughout the entire height of building structures. The outer skin is moveable and can act as a multi tuned mass dampers (MTMDs) that move and dissipate energy during strong earthquake motions. In this paper, using a three dimensional 10-storey building structure as the example, it is shown that with optimal choice of materials for stiffness and damping of brackets connecting the two skins, a substantial portion of earthquake induced vibration energy can be dissipated which leads to avoiding expensive ductile seismic designs. It is shown that the engineering demand parameters (EDPs) for a low-rise building structures subjected to moderate to severe earthquakes can be substantially reduced by introduction of a smart designed double skin system.

A Clinical Study on the Outcome of Chuna Treatment of Adolescent Structural Scoliosis (청소년기의 구조적 척추측만증에 대한 추나치료 결과 고찰)

  • Heo, Su-Young
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.2 no.1
    • /
    • pp.121-132
    • /
    • 2001
  • Objectives The present study retrospectively investigated clinical outcome of patients with structual scoliosis during Chuna treatment. Methods : The study population consisted of 34 patients(14 patients of adolescent and 20 patients of adult) who were diagnosised as scoliosis with radiological finding. All patients were treated with Chuna treatment, and after treatment, evaluated with radiological measurement by calculating the scoliosis correction angle from the Initial and follow-up spine AP and lateral views. Also the evaluation of clinical outcome was done twice pre and post treatment during this study. Results : The results were summarized as follows ; 1) The 85.3 percent of patients complained physical pain. and adult group had various painful lesion compared with adolescent group. 2) Adult group had treated $18.0{\pm}7.2$ times and adolescent group treated $13.5{\pm}5.7$ times with Chuna treatment. 3) Scoliotic angle is reduced in 92.9 percent of adolescent group and had all of adult group after Chuna treatment, especially, statistically significance appeared in adult group. 4) Adult group was superior to adolescent group in correctability and scoliotic angle change. 5) Correction effect was better in the group which initial scoliotic angle was lessor, or had more time of treatment. 6) According to grade of vertebral body rotation, scoliotic angle is larger and correctability was lower. Conclusions : Chuna treatment was efficacious against scoliosis. And it is necessary for adolescent scoliosis patient to be more carefully treated and observed.

  • PDF

Evaluation on performances of a real-time microscopic and telescopic monitoring system for diagnoses of vibratory bodies

  • Jeon, Min Gyu;Doh, Deog Hee;Kim, Ue Kan;Kim, Kang Ki
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1275-1280
    • /
    • 2014
  • In this study, the performance of a real-time micro telescopic monitoring system is evaluated, in which an artificial neural network is adopted for the diagnoses of vibratory bodies, such as solid piping system or machinery. The structural vibration was measured by a non-contact remote sensing method, in which images of a high-speed high-definition camera were used. The structural vibration data that can be obtained by the PIV (particle image velocimetry) technique were used for training the neural network. The structures of the neural network are dynamically changed and their performances are evaluated for the constructed diagnosis system. Optimized structures of the neural network are proposed for real-time diagnosis for the piping system. It was experimentally verified that the performances of the neural network used for real-time monitoring are influenced by the types of the vibration data, such as minimum, maximum and average values of the vibration data. It concludes that the time-mean values are most appropriate for monitoring the piping system.

Adjoint Variable Method Combined with Complex Variable for Structural Design Sensitivity (보조변수법과 복소변수를 연동한 설계 민감도 해석 연구)

  • Kim, Hyun-Gi;Cho, Maeng-Hyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.3
    • /
    • pp.243-250
    • /
    • 2009
  • The adjoint variable method can reduce computation time and save computer resources because it can selectively provide the sensitivity information for the positions that designers wish to measure. However, the adjoint variable method commonly employs exact analytical differentiation with respect to the design variables. It can be cumbersome to precisely differentiate every given type of finite element. This trouble can be overcome only if the numerical differentiation scheme can replace this exact manner of differentiation. But, the numerical differentiation scheme causes of severe inaccuracy due to the perturbation size dilemma. For assuring the accurate sensitivity without any dependency of perturbation size, this paper employs a complex variable that has been mainly used for computational fluid dynamics problems. The adjoint variable method combined with complex variables is applied to obtain the shape and size sensitivity for structural optimization. Numerical examples demonstrate that the proposed method can predict stable sensitivity results and that its accuracy is remarkably superior to traditional sensitivity evaluation methods.

Application of the Leak Before Break(LBB) Concept to a Heat Exchanger in a Nuclear Power Plant

  • Kwon, Jae-Do;Lee, Choon-Yeol;Lee, Yong-Son;Sul, Il-Chan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.10-20
    • /
    • 2001
  • The leak before break(LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount(approximately 37.9 liters) containing the radioactive material which can activate the radiation detector device installed in near the heat exchanger is assumed. A postulated initial flaw size that can not grow to a critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat exchanger is not impeded. Particularly the informational scenario presented in this paper discusses an actual nuclear plant.

  • PDF

Girder Distribution Model for Existing Short and Medium Span Steel Girder Bridges (단·중경간 강형교 거더의 횡분배 모델)

  • Eom, Jun-Sik;Nowak, Andrzej S.;Lho, Byeong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.219-229
    • /
    • 2003
  • The objective of this work is to verify the Code specified girder distribution factors for short and medium span bridges. To accomplish this objective, field tests were carried out on seventeen simply supported highway bridges. This paper presents the procedure and results of field tests that were performed to verify girder distribution factors. Finite Element analyses previously performed at the University of Michigan indicated that in most cases currently used girder distribution factors specified in AASHTO Codes are too conservative. However, these studies also showed that for short spans and short girder spacings, the girder distribution factors can be too permissive. Therefore, this paper focused on experimental evaluation of girder distribution factors for short and medium span steel girder bridges. The results were compared with the distribution factors specified by AASHTO Standard (2000) and AASHTO LRFD Code (1998). It has been found that the measured girder distribution factors are lower than AASHTO values in most cases, and sometimes the code specified values are overly conservative. The research work involved formulation of the testing procedure, selection of structure, installation of equipment, measurements, and interpretation of the results.

Experimental Study on the Tensile Behaviors of Stud Connection with Hanger (행거로 보강된 스터드 접합부의 인장거동에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.231-238
    • /
    • 2004
  • This paper presents the tensile behavior of the stud connection between reinforced concrete(RC) and steel members. Hanger reinforcements are placed around the studs to transfer the tensile and flexural loads to the opposite side of the concrete member. Eight specimens for the tensile tests are tested with variables, which are the arrangement details of hanger reinforcements, the reinforcing bars, and the embedment length of stud. The results of the tensile tests show that hanger reinforcements are effective to increase tensile strength for stud connections. Hangers and reinforcing bars near stud bolts contributed to the reduction of brittle failure. From the evaluation on the tensile strength by previous design guidelines, it was shown that CCD (Concrete Capacity Design) method was more suitable for estimation of test strength.

Development of New Data Analysis Method to Evaluate Reliability of the Sensor or Measured Data (댐 매설 계측기 및 계측결과의 원격 신뢰성 평가를 위한 신호처리 기법의 개발)

  • Park, Hyung Choon;Hwang, Hea Jin;Lee, Jong Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.34-44
    • /
    • 2012
  • Many kind of sensors in the dam produce a lot of data associated with the maintenance and safety of the dam. So it is important to measure the reliability of the sensor (or measured data). In this paper, the new method using modified coherence function is proposed to measure the reliability of the sensor remotely. To verify feasibility of proposed method in the field, proposed method was applied to data of piezometer and earth pressure cell. Through field applications, the potential of the proposed method was verified.