• Title/Summary/Keyword: structural evaluation

Search Result 4,836, Processing Time 0.03 seconds

Fracture Analysis of Welded Plates using the J-integral (J-적분을 이용한 용접구조물의 파괴해석)

  • 심용래
    • Computational Structural Engineering
    • /
    • v.9 no.4
    • /
    • pp.173-179
    • /
    • 1996
  • Study of weldment fracture behavior includes thermal analysis, residual stress analysis, and fracture analysis. The J-integral loses its path-independency in a residual stress field. Therefore, it is necessary to develop a program to calculate the J-integral in a welded plate. In this study, theoretical formulation and program were developed for the evaluation of the J-integral at the crack tip of weldments. To verify equations and program, welded thin plate and thick plate were used to calculate residual stress and the J-integral.

  • PDF

Probabilistic Safety Analysis for Seismic Performance Evaluation of Bridges -Focused on Fragility Analysis using Capacity Spectrum Method- (교량의 내진성능 평가를 위한 확률적 지진안전성 분석 - 역량스펙트럼법을 이용한 지진취약도 분석을 중심으로-)

  • 이진학;김상훈
    • Computational Structural Engineering
    • /
    • v.17 no.2
    • /
    • pp.31-41
    • /
    • 2004
  • 몇 일 전 필자는 대전에 위치한 한 연구소에 근무하고 계신 분으로부터 지진취약도 분석에 관한 문의 전화를 받았다. 그분의 대학 후배가 지진취약도에 대한 연구를 하고 싶다는 내용이었다. 최근 필자는 그분 외에도 다른 분들과 함께 지진취약도 분석 및 이를 확장한 바람에 의한, 혹은 홍수에 의한 구조물의 확률적 안전성 분석에 관한 논의를 하곤 하였다. 현재까지 국내에서는 구조물의 취약도 분석에 대한 연구가 그다지 활발하지 않으나, 이에 대한 관심은 지속적으로 증가할 것으로 보여진다. 지진취약도를 한마디로 요약하면, "임의의 크기를 갖는 지진이 발생하였을 때, 구조물에 어느 규모 이상의 손상이 발생할 확률"을 의미하는 것으로, 구조물의 확률적 지진안전성으로 부를 수 있다. 예를 들어, "최대지반가속도가 0.1g인 지진이 발생하였을 때, 해당 구조물에 보수를 요하는 수준 이상의 손상이 발생할 확률이 30%이다"와 같은 정보를 지진취약도 곡선으로부터 읽을 수 있다. (중략)

Flexural Performance of Reinforced Concrete Beams Retrofitted with Different FRPs (섬유 접착 보강 철근콘크리트 보의 보강재료에 따른 휨 성능 비교)

  • 정상인;신영수;홍건호;박종환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.751-756
    • /
    • 2001
  • This paper deals with the experimental evaluation of the performance of R.C beams strengthened with aramid, glass and carbon fiber sheets. To evaluate the effects of FRPs on the flexural strengthening of the beams, strengthening ratio is adopted as a main variable. Seven beams were fabricated and strengthened under same tensile strength based on ultimate strength of FRPs and strengthening length. Deflection, flexural stiffness, strain of FRP, ultimate load and failure load are compared to evaluate the effects of FRPs on structural behavior of retrofitted beams. The results shows that little effects of FRPs on behavior of strengthened beams can be estimated and the fail modes are more influenced on structural behavior than that.

  • PDF

Evaluation of Structural Capacity of L-shaped Walls with Different Confinement Details Under Web-direction Lateral Force (복부방향 수평하중을 받는 L형 벽체의 횡보강근 구속에 따른 구조성능 평가)

  • 조남선;하상수;최창식;오영훈;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.65-70
    • /
    • 2001
  • The compression toe of structural wall is designed to resist the axial compression and shear force caused by wind or earthquake. The performance of shear wall used in tall building is highly influenced by combined shear and axial force. For this reason, it is possible to result in local brittle failure because of concentrated damage in the potential plastic hinge region under severe earthquake. Thus, it is necessary to establish the lateral confinement details at the plastic hinge of shear wall so that shear wall can behave a ductile manner, The objective of this study is to evaluate the seismic performance of L-shaped walls with different confinement details. For this purpose, three wall specimens were tested experimentally and also analyzed using Nonlinear FEM package.

  • PDF

Study on Seismic Performance Evaluation of Existing Apartment with Wall Type (벽식 노후 공동주택의 내진성능평가에 관한 연구)

  • Jeong Chul-Hwa;Chung Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.52-55
    • /
    • 2004
  • Before incorporating the earthquake-resistance design in design code(998), most of existing residential buildings were built without having lateral resistance capacity in addition to their structural peculiarity such as exterior stair ways, exterior elevator room. For these reasons, the retrofitting research demands for existing buildings arise recently and many retrofitting methods are proposed. These tasks are important to reduce the enormous economic loss and environmental issues. In this study, Scaled residential buildings with/without lateral resistance were tested and monitored with external lateral load especially toward the longer side of the building. From these experiments, enhanced retrofitting methods of old shear wall system are proposed and also compared with structural analysis.

  • PDF

Damage-Based Seismic Performance Evaluation of Reinforced Concrete Frames

  • Heo, YeongAe;Kunnath, Sashi K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • A damage-based approach for the performance-based seismic assessment of reinforced concrete frame structures is proposed. A new methodology for structural damage assessment is developed that utilizes response information at the material level in each section fiber. The concept of the damage evolution is analyzed at the section level and the computed damage is calibrated with observed experimental data. The material level damage parameter is combined at the element, story and structural level through the use of weighting factors. The damage model is used to compare the performance of two typical 12-story frames that have been designed for different seismic requirements. A series of nonlinear time history analyses is carried out to extract demand measures which are then expressed as damage indices using the proposed model. A probabilistic approach is finally used to quantify the expected seismic performance of the building.

Visualization of Delamination Region in Concrete Structures using Mode Shapes of Delaminated Concrete Section (I) : Modal Test (박리된 콘크리트의 진동 모드 형상을 이용한 콘크리트 구조물 박리 손상 영역 가시화 (I) : 모드 시험)

  • Oh, Taekeun;Shin, Sung Woo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.21-26
    • /
    • 2013
  • Delamination of cover concrete due to re-bar corrosion is a critical damage reducing structural safety of reinforced concrete structures. Therefore, it should be detected and evaluated to provide appropriate maintenance to recover structural integrity. Impact-echo method, which utilizes thickness vibration characteristics of delaminated concrete section, is effective for detection and evaluation of small areal size delamination. However, it may not be applicable for large areal size delamination in which flexural vibration modes are dominated. In this study, applicability of vibration mode shapes of delaminated concrete section is investigated for visualization of delamination region in concrete structures. Numerical and experimental modal tests are performed to estimate mode shapes of delaminated concrete section and linear absolute summation technique is proposed for effective visualization of delamination region based on estimated mode shapes.

A study of Military-Vehicle Maintenance Service Quality and Customer Satisfaction by Structural Equation Model(SEM) (구조방정식 모형을 이용한 군(軍) 정비부대 서비스품질과 고객만족 측정에 관한 연구)

  • Seo, Jung-Hwan
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2007.11a
    • /
    • pp.171-175
    • /
    • 2007
  • The Service sector has increased in importance over the last decade in troops. Military included public sector, but has very different peculiarity from other public institution. So it's necessary that developing an evaluation tool that measuring service quality and customer satisfaction for troops. This study was conducted to identify tile service quality factors which are utilized to measure military vehicle maintenance service quality and customer satisfaction. In this paper, developing a Structural Equation Model at 'three dimensional model of service quality', and it is applied to customers of military vehicle maintenance service.

  • PDF

The Development of pallet based on the DFSS Methodology and Value Engineering for Lighter Logistics (식스 시그마 DFSS 와 VE 를 이용한 경량 파렛트 설계)

  • Yoon, Min-Su;Whang, Jeong-Feel
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1334-1337
    • /
    • 2007
  • A steel pallet to carry lighter logistic articles is developed based on the DFSS(design for Six Sigma) methodology. Combining the conventional DFSS(Design For Six Sigma) methodology with that of VE(Value Engineering) is the novel feature of this paper to achieve maximum cost reduction. In this paper, systematical steps to achieve the required structural spec's are presented by conventional DMEDI(Define-Measure-Explore-Develop-Implement) process. To imply the target costing, evaluation of functions consisting of the pallet has been performed by value methodology. Then best design concept is selected in the Explore step, following structural optimization utilizing FEM. Finally the performance of prototype is investigated by pilot test in the Implement step. The developed steel pallet is being commercialized in the fields of automated ware house.

  • PDF

Evaluation of the Structural Coal Combustion Model in a Swirling Pulverized Coal Combustor (탈휘발 예측 코드를 활용한 탈휘발 및 촤반응 모델 평가)

  • Joung, Daero;Han, Karam;Huh, Kang Y.;Park, Hoyoung
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.2
    • /
    • pp.32-39
    • /
    • 2012
  • In this study, pre-processor code based on structural behavior of coal is applied to predict yields, pyrolysis rate and compositions of volatile and char. These parameters are used in the devolatilization and char burnout sub-models as user-defined functions of commercial CFD code. The predicted characteristics of these sub-models are compared with those employing the conventional model based on experiment and validated against the measurement of a 2.1 MW swirling pulverized coal flame in a semi-industrial scale furnace. And the influence of the turbulence-chemistry interaction on pulverized coal combustion is analyzed.