• Title/Summary/Keyword: structural displacement

Search Result 2,981, Processing Time 0.026 seconds

Seismic Performance Evaluation of bridge using DCM and CSM (변위계수법과 역량스펙트럼 방법을 이용한 교량의 내진성능 평가)

  • Nam Wang-Hyun;Song Jong-Keol;Chung Yeong-Hwa
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.1017-1024
    • /
    • 2006
  • Capacity spectrum method(CSM) of ATC-40(1996) and displacement coefficient method(DCM) of FEMA-273(1997) are applied to evaluate the seismic performance of bridges. In this study, equivalent response is obtained from nonlinear static analysis for the 3spans continues bridge and nonlinear maximum displacement response is calculated using CSM and DCM. Nonlinear maximum displacement response of DCM is larger than this of CSM. It is method that DCM can evaluate target displacement and ductility of structural to be easy and simple, but tend to overestimate the maximum displacement response. Therefore, this method is mainly used at preparation design level to evaluate the structural response. It is not desirable to evaluate the seismic performance using DCM.

  • PDF

Stationary random response analysis of linear fuzzy truss

  • Ma, J.;Chen, J.J.;Gao, W.;Zhao, Y.Y.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.4
    • /
    • pp.469-481
    • /
    • 2006
  • A new method called fuzzy factor method for the stationary stochastic response analysis of fuzzy truss with global fuzzy structural parameters is presented in this paper. Considering the fuzziness of the structural physical parameters and geometric dimensions simultaneously, the fuzzy correlation function matrix of structural displacement response in time domain is derived by using the fuzzy factor method and the optimization method, the fuzzy mean square values of the structural displacement and stress response in the frequency domain are then developed with the fuzzy factor method. The influences of the fuzziness of structural parameters on the fuzziness of mean square values of the displacement and stress response are inspected via an example and some important conclusions are obtained. Finally, the example is simulated by Monte-Carlo method and the results of the two methods are close, which verified the feasibility of the method given in this paper.

Dynamic and static structural displacement measurement using backscattering DC coupled radar

  • Guan, Shanyue;Rice, Jennifer A.;Li, Changzhi;Li, Yiran;Wang, Guochao
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.521-535
    • /
    • 2015
  • Vibration-based monitoring is one approach used to perform structural condition assessment. By measuring structural response, such as displacement, dynamic characteristics of a structure may be estimated. Often, the primary dynamic responses in civil structures are below 5 Hz, making accurate low frequency measurement critical for successful dynamic characterization. In addition, static deflection measurements are useful for structural capacity and load rating assessments. This paper presents a DC coupled continuous wave radar to accurately detect both dynamic and static displacement. This low-cost radar sensor provides displacement measurements within a compact, wireless unit appropriate for a range of structural monitoring applications. The hardware components and operating mechanism of the radar are introduced and a series of laboratory experiments are presented to assess the performance characteristics of the radar. The laboratory and field experiments investigate the effect of factors such as target distance, motion amplitude, and motion frequency on the radar's measurement accuracy. The results demonstrate that the radar is capable of both static and dynamic displacement measurements with sub-millimeter accuracy, making it a promising technology for structural health monitoring.

A vision-based system for dynamic displacement measurement of long-span bridges: algorithm and verification

  • Ye, X.W.;Ni, Y.Q.;Wai, T.T.;Wong, K.Y.;Zhang, X.M.;Xu, F.
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.363-379
    • /
    • 2013
  • Dynamic displacement of structures is an important index for in-service structural condition and behavior assessment, but accurate measurement of structural displacement for large-scale civil structures such as long-span bridges still remains as a challenging task. In this paper, a vision-based dynamic displacement measurement system with the use of digital image processing technology is developed, which is featured by its distinctive characteristics in non-contact, long-distance, and high-precision structural displacement measurement. The hardware of this system is mainly composed of a high-resolution industrial CCD (charge-coupled-device) digital camera and an extended-range zoom lens. Through continuously tracing and identifying a target on the structure, the structural displacement is derived through cross-correlation analysis between the predefined pattern and the captured digital images with the aid of a pattern matching algorithm. To validate the developed system, MTS tests of sinusoidal motions under different vibration frequencies and amplitudes and shaking table tests with different excitations (the El-Centro earthquake wave and a sinusoidal motion) are carried out. Additionally, in-situ verification experiments are performed to measure the mid-span vertical displacement of the suspension Tsing Ma Bridge in the operational condition and the cable-stayed Stonecutters Bridge during loading tests. The obtained results show that the developed system exhibits an excellent capability in real-time measurement of structural displacement and can serve as a good complement to the traditional sensors.

Displacement Measuring Method using Terrestrial LiDAR for Safety and Serviceability Monitoring of Steel Beams (지상 LiDAR를 이용한 철골보의 안전 및 사용성 모니터링을 위한 변위 계측기법)

  • Lee Hong-Min;Park Hyo-Seon;Lee Im-Pyeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.190-197
    • /
    • 2005
  • To monitor the safety and serviceability of a structures, structural responses including displacements due to various design and unexpected loadings must be measured. The maximum displacement and its distributions of a structure can be used as a direct assessment index on its stiffness. For this reason, there have been diversely studied on measuring of the maximum displacement of a structure. However, there is no practical method for measuring displacement of a structure. Therefore, in this paper, new displacement measuring method is developed and accuracy of LiDAR is examined in detail for development of a new method for measuring displacement of a structure.

  • PDF

A Study on the Displacement Measuring Method of High-rise Buildingas using LiDAR (라이다를 이용한 고층 건물의 변위 계측 기법에 관한 연구)

  • Lee Hong-Min;Park Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.151-158
    • /
    • 2006
  • Structural health monitoring is concerned with the safety and serviceability of the users of structures, especially for the case of building structures and infrastructures. When considering the safety of a structure, the maximum stress in a member due to live load, earthquake, wind, or other unexpected loadings must be checked not to exceed the stress specified in a code. It will not fail at yield, excessively large displacements will deteriorate the serviceability of a structure. To guarantee the safety and serviceability of structures, the maximum displacement in a structures must be monitored because actual displacement is a direct assessment index on its stiffness. However, no practical method has been reported to monitor the displacement, especially for the case of displacement of high-rise buildings because of not to easy accessive. In this paper, it is studied displacement measuring method of high-rise buildings using LiDAR The method is evaluated by analyzing accuracy of measured displacements for existing building.

  • PDF

Properties of ATMD with Acceleration Feedback System (가속도귀환방식에 의한 ATMD의 특성)

  • 최민호;강병두;노필성;김재웅
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.10a
    • /
    • pp.242-249
    • /
    • 1995
  • In order to search more efficient structural control algorithm, several closed-loop algorithm are developed. Among those, feedback control algorithm using parameters as displacement velocity, and acceleration has been studied. In this paper, especially the characteristics of accleration feedback is studied as more efficient control algorithm than any others. Furthermore the fact that ATMD with acceleration feedback system further reduce the variance of structural displacement rather than with displacement or velocity feedback system will be examined and proved.

  • PDF

Soil structure interaction effects on structural parameters for stiffness degrading systems built on soft soil sites

  • Aydemir, Muberra Eser
    • Structural Engineering and Mechanics
    • /
    • v.45 no.5
    • /
    • pp.655-676
    • /
    • 2013
  • In this study, strength reduction factors and inelastic displacement ratios are investigated for SDOF systems with period range of 0.1-3.0 s considering soil structure interaction for earthquake motions recorded on soft soil. The effect of stiffness degradation on strength reduction factors and inelastic displacement ratios is investigated. The modified-Clough model is used to represent structures that exhibit significant stiffness degradation when subjected to reverse cyclic loading and the elastoplastic model is used to represent non-degrading structures. The effect of negative strain - hardening on the inelastic displacement and strength of structures is also investigated. Soil structure interacting systems are modeled and analyzed with effective period, effective damping and effective ductility values differing from fixed-base case. For inelastic time history analyses, Newmark method for step by step time integration was adapted in an in-house computer program. New equations are proposed for strength reduction factor and inelastic displacement ratio of interacting system as a function of structural period($\tilde{T}$, T) ductility (${\mu}$) and period lengthening ratio ($\tilde{T}$/T).

Hybrid displacement FE formulations including a hole

  • Leconte, Nicolas;Langrand, Bertrand;Markiewicz, Eric
    • Structural Engineering and Mechanics
    • /
    • v.31 no.4
    • /
    • pp.439-451
    • /
    • 2009
  • The paper deals with the problem related to the modelling of riveted assemblies for crashworthiness analysis of full-scale complete aircraft structures. Comparisons between experiments and standard FE computations on high-energy accidental situations onto aluminium riveted panels show that macroscopic plastic strains are not sufficiently localised in the FE shells connected to rivet elements. The main reason is related to the structural embrittlement caused by holes, which are currently not modelled. Consequently, standard displacement FE models do not succeed in initialising and propagating the rupture in sheet metal plates and along rivet rows as observed in the experiments. However, the literature survey show that it is possible to formulate super-elements featuring defects that both give accurate singular strain fields and are compatible with standard displacement finite elements. These super-elements can be related to the displacement model of the hybrid-Trefftz principle of the finite element method, which is a kind of domain decomposition method. A feature of hybrid-Trefftz finite elements is that they are mainly used for elastic computations. It is thus proposed to investigate the possibility of formulating a hybrid displacement finite element, including the effects of a hole, dedicated to crashworthiness analysis of full-scale aeronautic structures.

Identification of structural systems and excitations using vision-based displacement measurements and substructure approach

  • Lei, Ying;Qi, Chengkai
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.273-286
    • /
    • 2022
  • In recent years, vision-based monitoring has received great attention. However, structural identification using vision-based displacement measurements is far less established. Especially, simultaneous identification of structural systems and unknown excitation using vision-based displacement measurements is still a challenging task since the unknown excitations do not appear directly in the observation equations. Moreover, measurement accuracy deteriorates over a wider field of view by vision-based monitoring, so, only a portion of the structure is measured instead of targeting a whole structure when using monocular vision. In this paper, the identification of structural system and excitations using vision-based displacement measurements is investigated. It is based on substructure identification approach to treat of problem of limited field of view of vision-based monitoring. For the identification of a target substructure, substructure interaction forces are treated as unknown inputs. A smoothing extended Kalman filter with unknown inputs without direct feedthrough is proposed for the simultaneous identification of substructure and unknown inputs using vision-based displacement measurements. The smoothing makes the identification robust to measurement noises. The proposed algorithm is first validated by the identification of a three-span continuous beam bridge under an impact load. Then, it is investigated by the more difficult identification of a frame and unknown wind excitation. Both examples validate the good performances of the proposed method.