• Title/Summary/Keyword: structural detail

Search Result 796, Processing Time 0.026 seconds

Structural Safety Assessment of Mark III Membrane Type Liquid Natural Gas Cargo Containment System under Ice Collision (빙 충돌에 대한 Mark III 멤브레인형 LNG CCS의 구조 안전성 평가)

  • Nho, In Sik;Yun, Young-Min;Park, Man-Je;Oh, Young-Taek;Kim, Sung-Chan
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.126-132
    • /
    • 2014
  • In this study, a method for analyzing the collision and interaction between ice bergy bits and a Mark III type liquid natural gas (LNG) carrier was considered, and the structural safety of a ship's hull and cargo containment system (CCS) was evaluated. In the analysis, a constitutive model implementing the strain rate dependant mechanical property was used to consider the typical material characteristics of ice rationally. A relatively simple and easy ice structure interaction analysis procedure, compared with the accurate but complicated FSI analysis scheme, was suggested. When the ice bergy bits collided with ship's side hull under the four assumed scenarios, the structural behaviors of the ship structure and LNG CCS were simulated by applying the suggested ice collision analysis procedure using the commercial hydro-code LS-DYNA. In addition, the effects of the shapes and colliding speed of the ice bergy bits on the ice-structure interaction and safety of the CCS were examined in detail.

Grillage Method Applied to the Planning of Ship Docking

  • Kim, Sung Chan;Ryu, Cheolho;Lee, Jang Hyun;Lee, Kyung Seok
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.2 no.3
    • /
    • pp.150-157
    • /
    • 2016
  • When blocks are supported on a dock, huge reaction forces concentrated at the supports cause structural damage owing to local stress concentrations. Thus, the supports should be arranged to avoid local failure from the reaction forces by redistributing those forces. Docking analyses to determine the proper blocks and their support arrangements are introduced so that the local stresses are minimized to warrant the safety of the docking supports. Local stresses enforced by the support arrangement should be evaluated by finite element analysis (FEA). However, it is difficult to consider an accurate 3D geometry of the blocks in the finite element model because the structural design information is too complicated to determine within several days using the FEA model. This paper presents a simplified FE model to evaluate the safety of the arrangement of supports using a simplified grillage element. The grillage element can be efficiently used to obrain the reaction forces in docking analysis becasuse the reaction forces at the supports are enough to assess the safety of block. Since a simplified grillage model of the entire ship cannot accurately calculate the local stresses, an optimized modeling method based on the grillage element was introduced. The local reaction forces obtained by the proposed approach and three-dimensional FEA were discussed for typical types of ships. It is shown that the reaction forces obtained by the present grillage model are in reasonably good agreement with the FEA model.

An Experimental Study on Longitudinal Shear Capacity of Composite Slab Embedded with Silence Insulator (방음재를 삽입한 합성슬래브의 수평전단성능에 관한 실험적 연구)

  • Lee, Seon-Keun;Lee, Chy-Hyoung;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.64-71
    • /
    • 2018
  • This paper provides the results for experimental study on longitudinal shear performance for new-concept composite slabs embedded with silence insulator. Longitudinal shear capacity tests are used to predict characteristics of composite action between the concrete block, silence insulator and deckplate. A total set of 7 Push-Down specimens are tested to clarify the composite action between the concrete block, silence insulator and deckplate. Parameters in this study are the width of T-type bar, the depth of reinforced bar and the thickness of silence insulator. The results from experimental study on longitudinal shear capacity for new-concept composite slabs applied T-type bar, Reinforced bar and Silence insulator are summarized as follows. In test result, the Longitudinal Shear Capacity of the new concept specimen is 2 times excellent than basic specimen with safety. It is expected that applying the proposed composite slab detail at the actual site will provide a significant safety factor in structural aspect of the existing composite slab, and greatly contribute to the improvement capacities of resisting vibration and sound.

Structural Relationships among Frontline Hotel Employees' Core Self-evaluations, Perceived Customer Verbal Aggression and Turnover Intention (호텔직원의 핵심자기평가, 지각된 고객언어폭력 및 이직의도 간의 구조적 관계)

  • Kim, Tae-Goo;Lee, Gye-Hee
    • Culinary science and hospitality research
    • /
    • v.18 no.4
    • /
    • pp.100-117
    • /
    • 2012
  • The purpose of this study is to investigate the structural relationships among frontline hotel employees' core-self evaluations (self-esteem, generalized self-evaluations, locus of control, and emotional stability) as personal resources, customer verbal aggression as a job stressor, and turnover intention as a job outcome. Data were gathered from a sample of frontline employees of 10 five-star hotels in Busan via self-administered questionnaires. A total number of 405 questionnaires were utilized. This study used structural equation modeling to verify the research model and hypotheses. As hypothesized, the results demonstrated that core-self evaluations reduced customer verbal aggression and turnover intention, and customer verbal aggression amplified turnover intention. Finally, practical implications were discussed in detail and limitations of the study and future research directions were also suggested.

  • PDF

Estimation Formula for Shear Strength of RCS Beam-Column Joint (RCS 보-기둥 접합부의 전단강도 산정식 평가)

  • Chang, Kug-Kwan;Jeon, Choong-Geun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.1-9
    • /
    • 2015
  • This study is on the shear strength of the internal joints of RCS composite structure consisting of reinforced concrete column and steel beam. As a newly structure system, the composite system has been developed to fully utilize the advantages of reinforced concrete column and steel beam, which also include economic and practical joint detail. Nevertheless stress transfer mechanism and structural behavior of the joints had not been still clearly revealed and shown much difference from the proposed equation. In this study, by observing the crossing of reinforced concrete column through steel beam to the RCS structure beam type, thirty seven shear failure specimens were selected and applied to the 5 major equations which is used to calculate the shear strength of RCS joint. Through the regression analysis, modified equation which is more reliable and approximate results for shear strength of RCS joints was proposed.

Statistical characteristics of sustained wind environment for a long-span bridge based on long-term field measurement data

  • Ding, Youliang;Zhou, Guangdong;Li, Aiqun;Deng, Yang
    • Wind and Structures
    • /
    • v.17 no.1
    • /
    • pp.43-68
    • /
    • 2013
  • The fluctuating wind induced vibration is one of the most important factors which has been taken into account in the design of long-span bridge due to the low stiffness and low natural frequency. Field measurement characteristics of sustained wind on structure site can provide accurate wind load parameters for wind field simulation and structural wind resistance design. As a suspension bridge with 1490 m main span, the Runyang Suspension Bridge (RSB) has high sensitivity to fluctuating wind. The simultaneous and continuously wind environment field measurement both in mid-span and on tower top is executed from 2005 up to now by the structural health monitoring system installed on this bridge. Based on the recorded data, the wind characteristic parameters, including mean wind speed, wind direction, the turbulence intensity, the gust factors, the turbulence integral length, power spectrum and spatial correlation, are analyzed in detail and the coherence functions of those parameters are evaluated using statistical method in this paper. The results indicate that, the turbulence component of sustain wind is larger than extremely strong winds although its mean wind speed is smaller; the correlation between turbulence parameters is obvious; the power spectrum is special and not accord with the Simiu spectrum and von Karman spectrum. Results obtained in this study can be used to evaluate the long term reliability of the Runyang Suspension Bridge and provide reference values for wind resistant design of other structures in this region.

Reliability Analysis for Fracture of Concrete Armour Units (콘크리트 피복재의 단면파괴에 대한 신뢰성 해석)

  • 이철응
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.2
    • /
    • pp.86-96
    • /
    • 2003
  • A fracture or breakage of the concrete armor units in the primary cover layer of breakwaters is studied by using the reliability analysis which may be defined as the structural stability. The reliability function can be derived as a function of the angle of rotation that represents the rocking of armor units quantitatively. The relative influences of all of random variables related to the material and geometric properties on the fracture of armor units is analyzed in detail. In addition, the probability of failure for the fracture of individual armor unit can be evaluated as a function of the incident wave height. Finally, Bernoulli random process and the allowable fracture ratio may be introduced together in this paper, by which the probability of failure of a breakwater due to the fracture of armer units can be obtained straightforwardly. It is found that the probability of failure of a breakwater due to the fracture of armor units may be varied with the several allowable fracture ratios. Therefore, it should be necessary to consider the structural stability as well as the hydraulic stability for the design of breakwaters with multi-leg slender concrete armor units of large size under wave action in deep water.

Notional-Load Plastic-Hinge Method for Steel Structure Design (강구조 설계를 위한 가상하중 소성활절 해석)

  • 김승억;윤영묵
    • Computational Structural Engineering
    • /
    • v.9 no.2
    • /
    • pp.103-113
    • /
    • 1996
  • This paper presents practical notional-load plastic-hinge method for a two-dimensional steel structure design. The proposed method incorporates the refined plastic-hinge concept for spread of plasticity together with a practical notional-load approach. The proposed method can assess realistically both strength and behavior of a structural system and its individual members in a direct manner. As a result, the method can be used for design without tedious separate member capacity checks, including the calculation of K-factor. The strengths predicted by the proposed method are then compared with those predicted by the exact plastic-zone analysis as well as by the conventional LRFD procedure. A good agreement is generally observed. The displacement predictions are compared with the plastic-zone solutions. Analysis and design guidelines in using the proporsed method are given in detail. Analysis and design procedures are recommended. Member sizes determined by the proposed method are compared with those determined by the LRFD method. It is concluded that the procedures are suitable for adoption in practice.

  • PDF

A Study on Algorithm for Determining Seismic Improvement Priority of Highway Bridges (도로교 내진보강 우선순위 결정을 위한 알고리즘에 관한 연구)

  • Kim, Hyung-Gyu;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.138-147
    • /
    • 2018
  • With the recent series of damage caused by earthquakes in Korea, such as Gyeongju and Pohang, we know that Korea is no longer a safe zone for earthquakes and that we need to be prepared for them. In addition, bridges built prior to the introduction of seismic design concepts remain without adequate seismic reinforcement measures, and earthquake reinforcement should be performed efficiently considering economic and structural safety. Preliminary assessment of seismic performance of existing bridges is divided into four seismic groups, taking into account seismicity, vulnerability and Impact, considering the magnitude of the existing bridge's seismic, and prioritization for further evaluation of seismic performance. In this study, unlike the existing anti-seismic reinforcement priority method, scores are calculated based on the seismic design criteria applied to bridges, importance coefficient of the bridge including the zone coefficient and the Importance, vulnerability index of the bridge including the soil condition and the elapsed years, detail coefficient of the bridge including the superstructure form, the span length, the width, the height, the design load, and the daily traffic volume. The calculated score items will be weighted and grouped according to the results. Using this, a simpler and more efficient algorithm was proposed to determine the priority of seismic reinforcement on a bridge.

Characteristics of Rock Phase and Phenomena of Exfoliation, Breakout and Cracks Developed on the Rocks Constituting the Soongryemoon (숭례문의 육축을 이루는 석재의 암상 특징과 박리, 박락 및 균열현상)

  • Lee, Sang Hun
    • Journal of Conservation Science
    • /
    • v.11 no.1 s.14
    • /
    • pp.1-14
    • /
    • 2002
  • After the construction (1398 year at first, secondarily reconstructed at 1448 year), the Soongryemoon (South Gate) had been preserved to late 19c without large damages. The present shape of the gate have been kept after the repairments of two times (1953, 1963). However, the rocks constituting the walls of the gate have been strongly weathered, exfoliated and cracked due to severe changes in the environment as traffic increase, air pollution and the subway which may seem also to cause the structural unstability. The rocks composed of the walls of the gate are almost of granites. On the rocks such deteriorations as onion structure, surface exfoliation, cracks, and edge breakout are developed. These deteriorations may be caused genetically by strong weathering, differential load due to possibly structural unstability, impact and unknown reasons. For the establishment of conservation plan, the factors of these deterioration phenomena and structural unstability must be quantitatively analyzed and diagnosed in detail.

  • PDF