• Title/Summary/Keyword: structural capacity

Search Result 3,221, Processing Time 0.03 seconds

Structural Behavior of Beam-Column Joints Consisting of Composite Structures

  • Lee, Seung-Jo;Park, Jung-Min;Kim, Wha-Jung
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.111-120
    • /
    • 2002
  • This study proposes a joint model consisting of different types of members as a new structural system, and then investigates the resulting structural behavior. The joint model consists of a concrete-filled steel tube column (CFT) together with a steel reinforced concrete at the end plus reinforced concrete beam at the center. For comparison, two other joint models were designed, that are, a CPT with a reinforced concrete beam, and a CFT with a steel reinforced concrete at the end plus steel concrete beam at the center, then their joint capacity and rigidity, energy absorption capacity, etc., were all investigated. From the results, the CFT column with a steel reinforced concrete at the end plus steel concrete beam at the center was outstanding in terms of its capacity and rigidity. The results of this analysis demonstrate that an adequate connection type and reinforcement method with different materials of increasing the rigidity, thereby producing a capacity improvement along with protection from pre-fractures.

  • PDF

The ultimate bearing capacity of rectangular tunnel lining assembled by composite segments: An experimental investigation

  • Liu, Xian;Hu, Xinyu;Guan, Linxing;Sun, Wei
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.481-497
    • /
    • 2017
  • In this paper, full-scale loading tests were performed on a rectangular segmental tunnel lining, which was assembled by steel composite segments, to investigate its load-bearing structural behavior and failure mechanism. The tests were also used to confirm the composite effect by adding concrete inside to satisfy the required performance under severe loading conditions. The design of the tested rectangular segmental lining and the loading scheme are also described to better understand the bearing capacity of this composite lining structure. It is found that the structural ultimate bearing capacity is governed by the bond capacity between steel plates and the tunnel segment. The failure of the strengthened lining is the consequence of local failure of the bond at waist joints. This led to a fast decrease of the overall stiffness and eventually a loss of the structural integrity.

Evaluation on Structural Performance of Structural Insulated Panels in Wall Application (벽식 구조체 적용을 위한 구조용단열패널 성능 평가)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Lee, Cheol-Hee;Hwang, Sung-Wook;Jo, Hye-Jin;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.

Difference of Deterioration According to Exposed Condition of Column in Wooden Traditional Building (노출 환경에 따른 목조 고건축물 기둥의 열화 차이)

  • Kim, Gwang-Chul;Bae, Mun-Sung;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.58-68
    • /
    • 2003
  • Capacity assessment of structural member must be ahead of the safety assessment of wooden traditional building. Capacity assessment of structural member has been dependent on empirical method with visual inspection even now. Safety assessment of building, however, can be more correct and reasonable provided non-destructive evaluation technique that scientific and logic would be used to evaluate the capacity of structural member. For that purpose, non-destructive evaluation technique was applied to column among many structural members of wooden traditional building to examine the possibility of capacity assessment of structural member. And then, those data will be used as a basic data for capacity assessment of structural member in a following study. Specially, deterioration progress levels of column according to exposed condition were measured. Similar results were obtained as compared with results of visual inspection, so there was a good possibility of application for non-destructive evaluation technique.

A Study on the Load Carrying Capacity Assessment of the Preflex Beam Bridge (프리플렉스 합성형교의 내하력 평가에 관한 연구)

  • 채원규
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.145-150
    • /
    • 1997
  • In this thesis, the field test by truck load and the structural analysis were performed on a preflex beam bridge to investigate the load carrying capacity. From the field test and the structural analysis results, K(corrective factor) and $P_n$(load carrying capacity) of the preflex beam bridges were studied, and these factors were applied to the load carrying capacity assessment of the preflex bridges.

  • PDF

A Study on the Load Carrying Capacity Assessment Method of the Prestressed Concrete Beam Bridges (연속 프리스트레스트 콘크리트 빔교의 내하력 평가 기법에 관한 연구)

  • 채원규
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.126-134
    • /
    • 1998
  • In this paper, the field test by truck load and the structural analysis were performed on a prestressed concrete beam bridge to investigate the load carrying capacity of the prestressed concrete beam bridges. From the results of the field test and the structural analysis, CAF (composite action factor), TIF(transformed impact factor), and $P_n$(load carrying capacity) of the prestressed concrete beam bridges were studied, and the load carrying capacity assessment of the prestressed concrete beam bridges were carried out using these factors.

  • PDF

A Study on Evaluation of Performance Point for the Latticed Dome (래티스 돔의 성능점 산정에 관한 연구)

  • Han Sang-Eul;Lee Sang-Joo;Gan Eun-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.317-324
    • /
    • 2006
  • Performance-based design concept is needed to evaluate the seismic capacity of building. In this study, the method estimating the performance point of the spatial structures based on capacity spectrum method (CSM) is proposed. And for efficient evaluation for the performance point of the spatial structures, the algorithm to convert spatial structural system to ESDOF system is simulated Its efficiency is confirmed by comparing with time history analysis of full model. And dynamic behaviors of spatial structures are examined by using this method. At last, evaluation of structural performance according to variation of stiffness after plastic deformation on the substructures is carried out.

  • PDF

P-${\Delta}$ Effects on the Reliability of Offshore Platforms

  • Leon, David-De;Dante Campos
    • Computational Structural Engineering : An International Journal
    • /
    • v.3 no.1
    • /
    • pp.31-37
    • /
    • 2003
  • A typical marine platform in the Bay of Campeche is studied from the standpoint of structural reliability, and several characteristics of its deck such as slenderness and diameter/thickness ratios of the legs and actual degree of correlation between some variables are taken into account. The global and local buckling capacities of the deck legs are compared and the correlation coefficient between the critical axial load and the critical moment is assessed in order to validate its influence on the structural reliability. In addition, the influence of the vertical load, and its uncertainty, on the variance of the decks capacity, and latter on, on the platform's failure probability is assessed. The results presented may be used in future studies to further extend and upgrade the first version of the Reference Norm (PEMEX, 2000) and, in the longer term, to improve the current practice in the Design and Requalification of Offshore Marine Platforms in the Bay of Campeche.

  • PDF

Buckling Enhancement of Column Strips with Piezoelectric Layer

  • Wang, Quan;Wang, Dajun
    • Computational Structural Engineering : An International Journal
    • /
    • v.3 no.1
    • /
    • pp.49-59
    • /
    • 2003
  • This paper discusses the enhancement of the buckling capacity of column strips by use of piezoelectric layer. The analytical model for obtaining the buckling capacity of the piezoelectric coupled column with general boundary conditions modelled with different types of springs applied at the ends of the column is derived the first time. Based on this proposed model, the buckling capacity of the column strips can be accurately predicted by solving an eigenvalue problem. The computational results show the great potential of the piezoelectric materials in enhancing the buckling capacity of the column strips. The optimal locations of the piezoelectric layer for higher buckling capacity are also obtained for the columns with. standard pinned-pinned, fixed-free, and fixed-pinned structures. In addition, the buckling capacity and the increase of buckling capacity are discussed for those columns with the general boundaries as well. This research may provide a benchmark for the buckling analysis of the piezoelectric coupled strips.

  • PDF

Effects of gamma irradiation on the functional and structural characteristics of soy protein isolates (방사선 조사가 분리대두단백의 기능적, 구조적 특성에 미치는 영향)

  • 오경남;이숙영
    • Korean journal of food and cookery science
    • /
    • v.20 no.3
    • /
    • pp.256-264
    • /
    • 2004
  • The effects of irradiation on the functional and structural characteristics of soy protein isolates were studied. Soymilk was irradiated at 1, 5, and l0kGy, after which soy protein isolates were prepared. The functional properties of soy protein isolates were examined including solubility, emulsion capacity and stability, foam capacity and stability, structural properties as represented by SDS-PAGE pattern, and secondary and tertiary structures. The solubility and emulsion capacity were increased by radiation treatment at 1kGy however the values were adversely affected again as dosage was increased above 5kGy. As irradiation dosage increased, an increase of foaming capacity at 1kGy and a decreasing turnover afterwards were also noted in foaming capacity, although the differences were not statistically significant. The SDS-PAGE pattern showed fragmentation and aggregation of protein molecules as affected by irradiation in proportion to the dosage increase. The results of CD and fluorescence spectroscopy revealed increased aperiodic structure contents with the dosage increase. It was assumed that irradiation dosagefrom 5 to l0kGy could initiate minimal denaturation of protein in various foods compared to general heat treatment.