• Title/Summary/Keyword: structural analysis and design

Search Result 6,891, Processing Time 0.033 seconds

Use of design optimization techniques in solving typical structural engineering related design optimization problems

  • Fedorik, Filip;Kala, Jiri;Haapala, Antti;Malaska, Mikko
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1121-1137
    • /
    • 2015
  • High powered computers and engineering computer systems allow designers to routinely simulate complex physical phenomena. The presented work deals with the analysis of two finite element method optimization techniques (First Order Method-FOM and Subproblem Approximation Method-SAM) implemented in the individual Design Optimization module in the Ansys software to analyze the behavior of real problems. A design optimization is a difficult mathematical process, intended to find the minimum or maximum of an objective function, which is mostly based on iterative procedure. Using optimization techniques in engineering designs requires detailed knowledge of the analyzed problem but also an ability to select the appropriate optimization method. The methods embedded in advanced computer software are based on different optimization techniques and their efficiency is significantly influenced by the specific character of a problem. The efficiency, robustness and accuracy of the methods are studied through strictly convex two-dimensional optimization problem, which is represented by volume minimization of two bars' plane frame structure subjected to maximal vertical displacement limit. Advantages and disadvantages of the methods are described and some practical tips provided which could be beneficial in any efficient engineering design by using an optimization method.

A Study on Reliability Based Design Criteria for Bridge Foundation (교량기초의 신뢰성 설계규준에 관한 연구)

  • 손용우;정철원
    • Computational Structural Engineering
    • /
    • v.6 no.1
    • /
    • pp.77-89
    • /
    • 1993
  • Current Bridge foundation design is based on Working Stress Design(WSD), but Load Factor Based on Optimum Reliability(LFBOR) design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the bridge foundation, which is most common type of bridge foundation(Shallow, Pile and Caission), and also proposes the theoretical basis of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis of bridge foundation and the uncertainty measuring algorithms of each equation are also derived by Cornell's MFOSM(Mean First Order 2nd Moment Methods)using the stability analysis fourmula Highway Bridge Design Codes.

  • PDF

Seismic analysis of a steam generator for Gyeongju and Pohang earthquakes

  • Myung Jo Jhung;Youngin Choi;Changsik Oh;Gangsig Shin;Chan Il Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1577-1586
    • /
    • 2023
  • Safety qualification of a steam generator is a crucial issue related to faulted condition design loads, including earthquake loads, and it should be ensured that the structural integrity of a steam generator does not exceed its design load. Using data from the Gyeongju and Pohang earthquakes, the two most powerful recorded seismic events in Korea, seismic analyses of a typical steam generator are conducted in this study. The modal characteristics are used to develop an input deck for these analyses. With a time history analysis, the responses of the steam generator in the event of an earthquake are obtained. In particular, the displacement, velocity, and acceleration responses are obtained in the time domain, with these outcomes then used for a detailed structural analysis as part of the ensuing assessment. The response spectra are also generated to determine the response characteristics in the frequency domain, focusing on the response comparisons between the Gyeongju and Pohang earthquakes. Structural integrity can be ensured by performing additional analysis using results obtained from the time history analysis considering the input excitations of various earthquakes considered in the design.

An Integrated System for Aerodynamic, Structural, and RF Stealth Analysis of Flying Vehicles (비행체 공력-구조-RF 스텔스 통합해석 시스템에 관한 연구)

  • Park, Min-Ju;Lee, Dong-Ho;Myong, Rho-Shin;Cho, Tae-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.86-91
    • /
    • 2008
  • An integrated multidisciplinary analysis and design system plays a critical role in the preliminary design of an aircraft. In this work a system based on the CATIA is developed for multidisciplinary computational design; aerodynamics, elasticity, and radar frequency stealth. Common data base of geometry and rectangular grids is generated and used for aerodynamic and structural analysis, while derivative triangular grids are generated for the RCS calculation. The panel method (PANAIR), FEM (NASTRAN), and PO technique are used for aerodynamic, structural, and RF stealth computations, respectively, and several additional algorithms are developed for the effective communication of the common data.

A Numerical Model of Reinforced Concrete Members Exposed to Fire and After-Cooling Analysis (화재 및 화재 후 냉각상태의 철근콘크리트 부재 수치해석)

  • Hwang, Ju-Young;Kwak, Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.101-113
    • /
    • 2015
  • This paper introduces a numerical analysis method for reinforced-concrete(RC) members exposed to fire and proposes considerations in designing RC structures on the basis of the comparison between numerical results and design codes. The proposed analysis method consists of two procedures of the transient heat transfer analysis and the non-linear structural analysis. To exactly evaluate the structural behavior under fire, two material models are considered in this paper. One is "Under-Fire" condition for the material properties at the high temperature and the other one is "After-Cooling" condition for the material properties after cooling down to air temperature. The proposed method is validated through the correlation study between experimental data and numerical results. In advance, the obtained results show that the material properties which are fittable to the corresponding temperature must be taken into account for an accurate prediction of the ultimate resisting capacity of RC members. Finally, comparison of the numerical results with the design code of EN1992-1-2 also shows that the design code needs to be revised to reserve the safety of the fire-damaged structural member.

Design and Analysis of UHF-GPS Antenna for Autonomous Underwater Vehicles (자율무인잠수정용 UHF-GPS 안테나 설계 및 해석)

  • Sang-Jin Park;Yeong-Jun Jo;Dong-Hyun Seo;Lin-Keun Park
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.464-473
    • /
    • 2022
  • In this paper, about a lightweight design that satisfies the performance of UHF-GPS Antenna used in autonomous underwater vehicle is proposed. Structural analysis, watertight external pressure test and non-destructive testing used in the design process are decided in consideration of structural safety for operating external forces in the underwater environment. First, the material of radome is selected for the performance of the UHF-GPS Antenna for communication with the carrier on the underwater operation in consideration of the 20 bar pressure generated. And the material of radome as PA-GF is selected by conducting electromagnetic field analysis and structural analysis and by considering high strength, rigidity and high dielectric constant. Electromagnetic field analysis and structural analysis by the thickness of radome are additionally performed in order to satisfy the required weight of UHF-GPS antenna. After selecting the final model, its structural safety is verified through watertight external pressure test and non-destructive testing.

Development and application of construction monitoring system for Shanghai Tower

  • Li, Han;Zhang, Qi-Lin;Yang, Bin;Lu, Jia;Hu, Jia
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1019-1039
    • /
    • 2015
  • Shanghai Tower is a composite structure building with a height of 632 m. In order to verify the structural properties and behaviors in construction and operation, a structural health monitoring project was conducted by Tongji University. The monitoring system includes sensor system, data acquisition system and a monitoring software system. Focusing on the health monitoring in construction, this paper introduced the monitoring parameters in construction, the data acquisition strategy and an integration structural health monitoring (SHM) software. The integration software - Structural Monitoring/ Analysis/ Evaluation System (SMAE) is designed based on integration and modular design idea, which includes on-line data acquisition, finite elements and dynamic property analysis functions. With the integration and modular design idea, this SHM system can realize the data exchange and results comparison from on-site monitoring and FEM effectively. The analysis of the monitoring data collected during the process of construction shows that the system works stably, realize data acquirement and analysis effectively, and also provides measured basis for understanding the structural state of the construction. Meanwhile, references are provided for the future automates construction monitoring and implementation of high-rise building structures.

15kW-class wave energy converter floater design and structural analysis

  • Singh, Patrick Mark;Chen, Zhenmu;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.146-151
    • /
    • 2016
  • This study concentrates on the design of floater for 15kW-class wave energy converter that extracts the ocean energy by oscillating vertically along the wave motion. The floater connects to a arm structure that connects to a hydraulic cylinder, which drives a hydraulic generator. The study mainly focuses on the structural analysis of the floater. Previous studies have been conducted using a miniature model; however, this study focuses on the size selection of the floater for a full scale model. Static structural analysis is conducted using fine numerical grids. Due to the complexity of the whole model, it is analyzed as a separate component. There are several load cases for each floater size, and they are analyzed thoroughly for stress (von-mises, shear, and normal) and deformation. The initial design was conducted by scaling up from the miniature model of the previous study, and the final design has been redesigned by changing the thickness and internal support structure shape.

A Complementary Analysis for the Structural Safety Evaluation of the Spent Nuclear Fuel Disposal Canister for the Pressurized Water Reactor (가압경수로(PWR)용 고준위폐기물 처분용기의 구조적 안전성 평가 보완 해석)

  • Choi, Jong-Won;Kwon, Young-Joo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.427-433
    • /
    • 2007
  • A structural model of the spent nuclear fuel disposal canister for the pressurized water reactor(PWR) for about 10,000 years long term deposition at a 500m deep granitic bedrock repository has been developed. However this developed structural model of the spent nuclear fuel disposal canister is too heavy to handle without any structural safety problem. Hence a lighter structural model of the spent nuclear fuel disposal canister which is easy to handle has been tried to develop very much. One of the reasons which made the structural model heavy is considered to be due to the severe adaptation of the design conditions like external loads and safety factor etc. to the canister design. Hence a complementary analysis to alleviate such severe design conditions is required for the reduction of the canister weight. In this study, a complementary structural analysis for the spent nuclear fuel disposal canister is carried out changing the design conditions such as external loads and safety factors to recalculate the design parameters like diameter and thickness etc. of the canister. The complementary analysis results shows that the diameter of canister can be shortened from 122cm to 102cm to reduce the weight of the spent nuclear fuel disposal canister.