• Title/Summary/Keyword: stroke order

Search Result 564, Processing Time 0.029 seconds

Development and Verification of PZT Actuating Micro Tensile Tester for Optically Functional Materials

  • Kim Seung-Soo;Lee Hye-Jin;Lee Hyoung-Wook;Lee Nak-Kyu;Han Chang-Soo;Hwang Jai-Hyuk
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.477-485
    • /
    • 2005
  • This paper is concerned with the development of a micro tensile testing machine for optically functional materials such as single or poly crystalline silicon and nickel film. This micro tensile tester has been developed for testing various types of materials and dimensions. PZT type actuation is utilized for precise displacement control. The specifications of the PZT actuated micro tensile testers developed are as follows: the volumetric size of the tester is desktop type of 710mm' 200mm' 270mm; the maximum load capacity and the load resolution in this system are IKgf and 0.0152mgf respectively and; the full stroke and the stoke resolution of the PZT actuator are $1000{\mu}m$ and 10nm respectively. Special automatic specimen installing and setting equipment is applied in order to prevent unexpected deformation and misalignment of specimens during handling of specimens for testing. Nonlinearity of the PZT actuator is compensated to linear control input by an inverse compensation method that is proposed in this paper. The strain data is obtained by ISDG method that uses the laser interference phenomenon. To test the reliance of this micro tensile testing machine, a $200{\mu}m$ thickness nickel thin film and SCS (Single Crystalline Silicon) material that is made with the MEMS fabrication process are used.

Vibration Characteristics of a Model Ship with Weis-Fogh type Ship's Propulsion Mechanism (Weis-Fogh형 추진기구를 장착한 모형선의 진동특성)

  • Ro, Ki-Deok;Choi, Byeong-Kuen;Lee, Jeong-Hwan;Oh, Se-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • A model ship equipped with the Weis-Fogh type ship's propulsion mechanism, which is consisted of one wing in a squared channel, was constructed. Sailing and vibration tests of the model ship were performed with the opening angles in a pool. The results are summarized as follows. The thrust and the speed of model ship were the highest for the spring-type wing of which the opening angle is automatically controlled in one stroke. Moreover, these values were approximately reduced by 4% from $30^{\circ}$ opening angle to $15^{\circ}$ in order. The maximum amplitude and RMS values of the model ship were the lowest for the wing having the opening angle of $30^{\circ}$, but were the largest for spring-type wing. And in case of the same opening angle, these values were lower for the ship on sailing than that on stationary.

Development of the Special Heat Generating Terminal of Cauterizer for Prostate (전립선 전용 전자쑥뜸 발열단자의 개발)

  • Jo, Bong-Kwan;Lee, Yun-Ho
    • Journal of Acupuncture Research
    • /
    • v.26 no.2
    • /
    • pp.41-48
    • /
    • 2009
  • Objectives : The conventional direct and indirect moxibustion therapies for prostate treatment could not been applied to the acupuncture point of $CV_1$(Conception Vessel Meridian 1, 會陰) because of its boring body region. The position of $CV_1$(會陰) is the back side of hard part between the anus and the genital organ. The conventional moxibustion methods have many troubles in operating to the acupuncture point of $CV_1$(會陰). In order to get rid of these problems, we have suggested the special heat generating terminal especially for prostate. The features of the special heat generating terminal for prostate are the low temperature infrared heater and the adhesive moxa-pad. These features are no burnt, no fiery and especially suitable for the point of $CV_1$(會陰). Methods: The heat generating terminal which is a part of the moxa-extract moxibustion cauterizer is composed of a PTC(Positive Temperature Coefficients) ceramic heater and the adhesive moxa-pad We had got the experimental demonstrations by the stimulating the acupuncture points which are $CV_1$(會陰), $BL_{28}$(Bladder Meridian 28, 膀胱兪), and $CV_3$(Conception Vessel Meridian 3, 中極) with the special heat generating terminal for the prostatitis and the benign prosthetic hypertrophy. And the stimulation level was 43$^{\circ}C$ infrared heat for one hour. The type of thermography is IRIS-5000. Results : With one subject suffering the prostatitis and another subject suffering the benign prosthetic hypertrophy, we cauterized the acupuncture points $CV_1$(會陰), $BL_{28}$(膀胱兪) and $CV_3$(中極) with the special heat generating terminal for prostate. We measured the temperature variations by the thermography before and after stimulations. Finally we estimated the tendency of temperature decreasing in the region of post-stroke urinary symptoms and the improvement of nocturnal enuresis after the stimulations. Conclusions : We suggest that the special heat generating terminal of moxa-extract moxibustion cauterizer proposed herein is effective for the treatment of prostate by NIH-CPSI and IPSS.

  • PDF

The Study on The Snake Venom (사독(蛇毒)에 대한 문헌적(文獻的) 고찰(考察))

  • Lee, Jin-Seon;Kwon, Gi-Rok
    • Journal of Pharmacopuncture
    • /
    • v.2 no.1 s.2
    • /
    • pp.73-91
    • /
    • 1999
  • This study was carried out to invastigate the researches of Snake Venom and snakes which used in treatment 1. The fist literature that used the snake for treatment is Shin Nong Ben Cao Jing 2. Composition of Snake Venom is consist of Enzymatic proteins ; Phospholipase A(A1-2), Protease, L-amino acid oxidase etc, and Non-enzymatic proteins ; Crotamine(Cytolysin), Proteolytic factor(Hematoxin), Crotoxin(Neurotoxin) etc. 3. Main toxins in Snake Venom are Hematoxin, Cytolysin, Neurotoxin and Cardiotoxin. Lethal dose 50 value of Agkistrodon brevicaudus is $45.87{\mu}g$/18g, Agkistrodon saxatilis is $10.28{\mu}g$/18g, Agkistrodon ussuriensis is $8.68{\mu}g$/18g, therefore Agkistrodon ussuriensis has strongist Snake Venom of all in Korea. 4. Pharmacological actions of Snake Venom are anticoagulation, thrombolytic function, hypotensor etc. 5. Systemic syndromes and signs after snakebite are Dizziness(25.7%), Vomitting(23.1%), Fever(22%), Visual disturbance(18%), Headache(17.7%) and Dyspnea(17.6%), etc. 6. Local syndrome and sign after snakebite is Discoloration(54.2%), Bleeding(20.2%), Bullae(10.7%), Skinulcer(10.8%), etc. 7. Pathological syndromes after snakebite are WBC increase, Urine protein, Urine sugar, Haematuria and elevation of S-GDT, S-GPT etc. These syndromes are leaded by Hematoxin and Cytolysin. 8. Complication signs after snakebite are Cellulitis, Gastritis, Lympoma, Abscess etc. 9. Common function of Viperidae(Agkistrodon acutus or Zaocys dhumnades etc) is expelling the wind(祛風), removing obstruction in the channels(通絡), antipastic function(止痙). And it is used in order to cure hemiparesis, hemiplegia, facial palsy and CVA disease, etc. 10. Using way of snake for medical treatment is various like Herbal alchol therapy, pill, powder and injection etc. The Study on the Snake Venom should be carried out continuously for using of medical treatment.

Performance test and factor analysis on the performance of shutoff units with the research reactor (연구용 원자로의 정지봉 장치 성능에 미치는 인자 분석과 성능 시험)

  • Kim, Kyoung-Rean;Kim, Seoug-Beom;Ko, Jae-Myoung;Moon, Gyoon-Young;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.2 s.41
    • /
    • pp.41-45
    • /
    • 2007
  • The shutoff unit was designed to provide rapid insertion of neutron absorbing material into the reactor core to shutdown the reactor quickly and also to withdraw the absorber slowly to avoid a log-rate trip. Four shutoff units were installed on the HANARO reactor but the half-core test facility was equipped with one shutoff unit. The reactor trip or shutdown is accomplished by four shutoff units by insertion of the shutoff rods. The shutoff rod(SOR) is actuated by a directly linked hydraulic cylinder on the reactor chimney, which is pressurized by a hydraulic pump. The rod is released to drop by gravity, when triplicate solenoid valves are de-energized to vent the cylinder. The hydraulic pump, pipe and air supply system are provided to be similar with the HANARO reactor. The shutoff rod drops for 647mm stroke within 1.13 seconds to shut down the reactor and it is slowly inserted to the full down position, 700mm, with a damping. We have conducted the drop test of the shutoff rod in order to show the performance and the structural integrity of operating system of the shutoff unit. The present paper deals with the 647mm drop time and the withdrawal time according to variation of the pool water temperature, the water level and the core flow.

Development of Textile Pattern Design by Tessellation Technique using Iconography of Jeju's Hyojemunjado - Focused on characters - (제주도 효제문자도 도상을 활용한 테셀레이션 기법의 텍스타일 패턴디자인 개발 - 신(信)자도를 중심으로 -)

  • Jang, Ae Ran;Hyun, Myung Kwan
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.8
    • /
    • pp.78-97
    • /
    • 2016
  • The purpose of this study is to develop textile pattern designs by utilizing the prototype of traditional culture extracted from cultural resources in order to establish a specialty strategy for local cultural contents. To achieve this, the study selected the Hyojaemunjado as source of Jeju traditional culture. Jeju's Hyojaemunjado is characterized mainly by the creative and unique formativeness of Jeju's character paintings. Character paintings often contained images related to the characters featured inside characters, or composed stroke with symbolic iconography. The main subjects of Hyojaemunjado were stories that alluded to the Confucian virtues. Therefore, the purpose of this study was to remind people of the real meaning of Shin(truth) by developing textile pattern designs, which borrows the tessellation technique for design, and the dominant characteristic of geometric abstraction. This study used theoretical research and empirical analysis. First, the study did the theatrical research on Hyojaemunjado based on literature and precedent studies, and then analyzed the style of expression and formativeness on the Shin character paintings through real analysis of Jeju's Hyojaemunjado kept in Jeju National University Museum. Second, based on the analysis of the style(three-tier composition) and formativeness of Hyojaemunjado, it analyzed the formativeness of the iconography about Shin, i.e. character types(semi cursive style, square style) drawn according to the symbolic meaning, palace, unknown flower, pheasant, tile fish and constellation. Based on analysis of the iconography, it stylized the motives that became available on the Archimedean tiling of tessellation, and then developed the textile pattern designs by arranging the iconographic motives with Platonic tiling and Semi-tiling. The reason why this study borrowed tessellation was to create various visual effects using the size of angle, symmetry and change and joint with simple figure.

Application of Cardiac Electromechanical FE Model for Predicting Pumping Efficacy of LVAD According to Heart Failure Severity (심부전 정도에 따른 좌심실보조장치의 박동효율예측을 위한 심장의 전기역학적 유한요소 모델의 응용)

  • Jung, Dae Hyun;Lim, Ki Moo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.8
    • /
    • pp.715-720
    • /
    • 2014
  • In order to maximize the effect of left ventricular assist device (LVAD) on ventricular unloading, the therapy should be begun at appropriate level of heart failure severity. We predicted pumping efficacy of LVAD according to the severity of heart failure theoretically. We used 3 dimensional finite element model of ventricle coupled with 6 Wind-kessel compartmental model of vascular system. Using the computational model, we predicted cardiac responses such as contractile ATP consumption of ventricle, left ventricular pressure, cardiac output, ejection fraction, and stroke work according to the severity of ventricular systolic dysfunction under the treatments of continuous LVAD. Contractile ATP consumption, which indicates the ventricular energetic loading condition decreased maximally at the $5^{th}$ level heart-failure under LVAD therapy. We conclude that optimal timing for LVAD treatment is $5^{th}$ level heart-failure when considering LVAD treatment as "bridge to recovery".

Study on the Simulation of the Intake and Exhaust Systems of a Gasoline Engine Using BOOST (BOOST를 이용한 가솔린 기관 흡·배기 계통의 시뮬레이션에 관한 연구)

  • Lee, Dae-Kwon;Yoon, Keon-Sik;Ryu, Soon-Pil;Woo, Seok-Keun;Seong, Hwal-Gyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.23-32
    • /
    • 2013
  • This paper presents the simulation of the multi-cylinder 4-stroke cycle spark-ignition engine using a commercial simulation tool, AVL BOOST. Various models were examined to select the appropriate models that would best serve to analyze the main components of the intake and exhaust systems-the plenum chamber, the muffler and the exhaust manifold branch junction. For the plenum chamber and the muffler, the tank model and the pipe model were tested. In order to analyze the exhaust manifold branch junction, a complicated model which reflects the actual shape and involves pressure drops was compared to a simplified one. The results show that both the tank model and the pipe model are applicable with satisfying accuracies for the plenum chamber and the muffler. However, the tank model is more desirable in regards to convenience in modeling and efficiency in calculation. Though both the complicated model and the simplified model show satisfying accuracies for the exhaust manifold branch junction, the simplified model is recommended in regards to convenience in modeling and efficiency in calculation.

Design of Robust Servo Controller for Large Size Low Speed Diesel Engines (대형 저속 디젤기관의 속도제어를 위한 로바스트 서보 제어기 설계)

  • Jeong, Byeong-Geon;Yang, Ju-Ho;Byeon, Jeong-Hwan
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.1
    • /
    • pp.46-58
    • /
    • 1997
  • The energy saving is one of the most important factors for profit in marine transportation. In order to reduce the fuel oil consumtion the ship's propulsion efficiency must be increased as possible. The propulsion efficiency depends upon a combination of an engine and a propeller. The propeller has better efficiency as lower rotational speed. This situation led the engine manufacturers to design the engine that has low speed, long stroke and a small number of cylinders. Consequently, the variation of rotational torque became larger than before because of the longer delay-time in fuel oil injection process and an increased output per cylinder. As this new trends the conventional mechanical-hydrualic governors for engine speed control have been replaced by digital speed controllers which adopted the PID control or the optimal control algorithm. But these control algorithms have not enough robustness to suppress the variation of the delay-time and the parameter perturbation. In this paper we consider the delay-time and the perturbation of engine parameters as the modeling uncetainties. Next we design the robust servo controller which has zero offset in steady state engine speed, based on H sub($\infty$) control theory. The validity of the controller was investigated through the response simulation. We used a personal computer and an analog computer as the digital controller and the engine (plant) part respectively. And, we could certify that the designed controller maintains its robust servo performance even though the engine parameters may vary.

  • PDF

Assessment of Applicability of Standardized Rates for Health State Comparison Among Areas: 2008 Community Health Survey (지역 간 건강수준 비교를 위한 표준화율 적용의 적절성 평가: 2008년 지역사회건강조사를 바탕으로)

  • Kwon, Geun-Yong;Lim, Do-Sang;Park, Eun-Ja;Jung, Ji-Sun;Kang, Ki-Won;Kim, Yun-A;Kim, Ho;Cho, Seong-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.2
    • /
    • pp.174-184
    • /
    • 2010
  • Objectives: This study shows the issues that should be considered when applying standardized rates using Community Health Survey(CHS) data. Methods: We analyzed 2008 CHS data. In order to obtain the reliability of standardized rates, we calculated z-score and rank correlation coefficients between direct standardized rate and indirect standardized rate for 31 major indices. Especially, we assessed the change of correlations according to population composition (age and sex), and characteristics of the index. We used Mantel-Haenszel chi-square to quantify the difference of population composition. Results: Among 31 major indices, 29 indices' z-score and rank correlation coefficients were over 0.9. However, regions with larger differences in population composition showed lower reliability. Low reliability was also observed for the indices specific to subgroups with small denominator such as 'permanent lesion from stroke', and the index with large regional variations in age-related differences such as 'obtaining health examinations'. Conclusions: Standardized rates may have low reliability, if comparison is made between areas with extremely large differences in population composition, or for indicies with large regional variations in age-related differences. Therefore, the special features of standardized rates should be considered when health state are compared among areas.