• 제목/요약/키워드: strips

검색결과 889건 처리시간 0.023초

Optimization of disposable paper-based test strips for hypochlorous acid detection

  • Rita E. Ampiaw;Muhammad Yaqub;Changyeon Woo;Wontae Lee
    • Membrane and Water Treatment
    • /
    • 제14권4호
    • /
    • pp.181-189
    • /
    • 2023
  • The Covid-19 pandemic has increased demand for chlorine-based sanitizing solutions, most of which contain hypochlorous acid (HOCl) as an active agent. Free chlorine (HOCl) in these sanitizers is crucial for their efficacy. Disposable test strips are affordable and convenient tools for determining various qualitative and quantitative parameters. In this study, disposable opto-chemical test strips were developed by physically immobilizing 3,3',5,5'-tetramethylbenzidine (TMB) and o-dianisidine (o-D) reagents on chromatography and filter paper-based test strips for the visualization and detection of free chlorine in the form of HOCl. The reagents undergo a rapid color change upon reaction with chlorine through a redox reaction. The paper-based test strips showed rapid color change within a minute and a low sample volume requirement (1 ml). This portable, disposable paper-based test strip is a simple and cost-effective way to rapidly detect the presence of HOCl sanitizers for home and field applications. Both TMB and o-D successfully detected chlorine. Chromatography paper proved to be the more efficient option among the two papers used as substrates for the reagents (TMB and o-D). It exhibited high retention capacity and high performance in terms of color transformation when reacting with HOCl, even after two months of storage.

건조수축 및 온도영향에 대한 건조수축대의 효과 연구 (A Study on the Effect of the Shrinkage Strip on Shrinkage and Thermal Change of Concrete)

  • 김록배;김욱종;이도범;이운세
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.251-256
    • /
    • 2001
  • Shrinkage during the curing and drying of concrete is unavoidable and results in many cracks. Shrinkage strips reduce effectively shrinkage stresses and minimize shrinkage cracks by being left open for a certain time during construction allow a significant part of the shrinkage to occur without inducing stresses. This study verifies the effectiveness of shrinkage strips and provides the guide for construction of such strips.

  • PDF

공동주택 지하주차장의 건조수축 및 온도영향에 대한 수축대의 효과 연구 (A Study on the Effect of the Shrinkage Strip on Shrinkage and Thermal Change of Concrete in the Underground Parking Structure)

  • 김록배;김욱종;이도범;이운세
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.827-832
    • /
    • 2001
  • Shrinkage during the curing and drying of concrete is unavoidable and results in many cracks. Shrinkage strips reduce effectively shrinkage stresses and minimize shrinkage cracks by being left open for a certain time during construction to allow a significant part of the shrinkage to occur without inducing stresses. This study verifies the effectiveness of shrinkage strips and provides the guide for construction of such strips.

  • PDF

Integral formulas for strips

  • Kim, Yong-Il
    • 대한수학회논문집
    • /
    • 제12권4호
    • /
    • pp.985-998
    • /
    • 1997
  • For n random strips chosen so as to meet a fixed bounded convex set K of the plane we let $\nu$ be the number of intersection regions that meet K. We develop the integral formula for the mean value of $\nu$ and $\nu^2$ involving the area and the perimeter of K and the breadths of the strips. We get some geometric inequalities in way of studying integral geometry.

  • PDF

Restoring force model for circular RC columns strengthened by pre-stressed CFRP strips

  • Zhou, Changdong;Lu, Xilin;Li, Hui;Tian, Teng
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.371-386
    • /
    • 2014
  • This paper presents a tri-linear restoring force model based on the test results of 12 circular RC columns strengthened by CFRP strips under low cyclic loading. The pre-stress of CFRP strips and axial load ratio of specimens are considered as the affect parameters of the proposed model. All essential characteristics of the hysteretic behavior of the proposed model, including the hysteretic rules, main performance points, strength degradation, stiffness degradation and confinement effects are explicitly analyzed. The calculated results from the proposed model are in good agreement with the experimental results, which shows that the recommended model can be reliably used for seismic behavior predictions of circular RC columns strengthened by pre-stressed CFRP strips.

Seismic performance of retrofitted URM walls with diagonal and vertical steel strips

  • Darbhanzi, Abbas;Marefat, Mohammad S.;Khanmohammadi, Mohammad;Moradimanesh, Amin;Zare, Hamid
    • Earthquakes and Structures
    • /
    • 제14권5호
    • /
    • pp.449-458
    • /
    • 2018
  • Earthquakes have shown the vulnerability of unreinforced masonry (URM) structures. The aim of this research is to study a technique for in-plane seismic retrofitting of URM walls in which both diagonal and vertical steel strips are added to a single side of a URM wall. Specimens have been tested under quasi-static cyclic lateral load in combination with constant vertical load. The tests show that vertical and diagonal strips cause a significant increase in seismic capacity in terms of both strength (about 200%) and displacement at maximum (about 20%). Furthermore, this technique caused the failure modes of URM walls were influenced.

뒷채움 지반에 비정착식 띠보강재를 설치한 역T형 옹벽의 현장 계측 (Field Measurements of Cantilever Wall with Unattached Strips in the Backfill)

  • 이종구;이만수;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.87-94
    • /
    • 2000
  • This paper concerns the distribution of earth pressures on a cantilever wall with unattached reinforcements in the backfill. This type of walls is different from the existing reinforced earth walls in that unattached reinforcements are placed in the backfill of rigid retaining wall such as gravity wall and cantilever wall, instead of connecting reinforcements to the wall segments. Two large-scale prototype tests have been carried out with a 4m high cantilever wall; one with unreinforced backfill, the other with unattached strips in the backfill. The reinforcing effect of unattached strips are discussed based on the earth pressure distribution measured in two large-scale prototype tests. Also, the comparison between measured and predicted earth pressure on a wall with unattached strips are discussed herein to confirm the validity of analytical prediction.

  • PDF

Behaviour evaluation of shear connection by means of shear-connection strips

  • Rovnak, Marian;Duricova, Antonia
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.247-263
    • /
    • 2004
  • Comparison of behaviour of shear connections by means of shear-connection strips (perfobond and comb-shaped strips) and headed studs under static and repeated loading, possible failure modes of concrete dowels and ways of the quantitative differentiation of some failure modes are described in the paper. The article presents a review of knowledge resulting from the analysis of shear-connection effects based on tests of perfobond and comb-shaped strips carried out in the laboratories of the Faculty of Civil Engineering of the Technical University of Kosice (TU of Kosice) in Slovakia and their comparison with results obtained by other authors.

A Review on Lateral Flow Test Strip for Food Safety

  • Kim, Giyoung;Lim, Jongguk;Mo, Changyeun
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.277-283
    • /
    • 2015
  • Background: Foodborne disease outbreaks from various food sources are a major health concern worldwide. Current methods for detection of foodborne pathogens are both expensive and time-consuming. Purpose: This review aims to present the current information available on the use of lateral flow test strips to detect pathogens in food products to enhance food safety. Results: Frequent foodborne disease outbreaks from various food sources have increased the need for rapid and easy methods for routine analysis of foodborne pathogens. Present detection methods for foodborne pathogens require expensive instruments, experts, and long time for sample analysis. Lateral flow test strips have drawn attention in recent years because of their ability to detect analytes quickly and easily. This review focuses on the principle of the lateral flow test, the various formats of lateral flow test strips, recognition elements, labeling tags, and reading instruments. In addition, this review also discusses the future prospects for the lateral flow test strips.

식생피도가 식생여과대의 질소 및 인 처리효율에 미치는 영향 (Effect of Plant Coverage on the Treatment Efficiency of Nitrogen and Phosphorus in Vegetative Filter Strips)

  • 이병수;길경익
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.499-503
    • /
    • 2008
  • In order to control the non-point source pollution, a vegetative filter strips (VFS) was set up and the site-monitoring was performed. The objective of this study is to investigate the influence of the plant coverage on treatment efficiency of total nitrogen (T-N) and total phosphorus (T-P) using vegetative filter strips. According to the results, it seemed that the treatment efficiencies of T-N and T-P were closely related with the plant coverage ratio. The results showed that treatment efficiency of T-P average 50% at higher than 50% of the plant coverage and 20~23% at lower than 50% of the plant coverage. Also, the treatment efficiency of T-N increased with the increase of the plant coverage ratio.