• 제목/요약/키워드: strips

검색결과 890건 처리시간 0.025초

토끼의 장운동에 미치는 $K^+$Channel 개방제인 Cromakalim과 $K^+$Channel 차단제인 Glibenclamide의 영향 (Influence of Cromakalim, $K^+$Channel Opener, and Glibenclamide, $K^+$ Channel Blocker, on Intestinal Movements in Rabbit)

  • 고석태
    • Biomolecules & Therapeutics
    • /
    • 제9권4호
    • /
    • pp.237-243
    • /
    • 2001
  • This study was attempted to investigate the effects of cromakalim (CRK), $K^{+}$ channel opener, and glibenclamide (GLY), $K^{+}$ channel blocker, on intestinal function of rabbit. CRK supressed the tension and spontaneous movement of intestinal strips. CRK enhanced the tension and spontaneous movement of strips induced by acetylcholine. Also the inhibiting effect of dopamine was potentiated by CRK. GLY augmented the tension, but did not affect the spontaneous movement of strips. GLY inhibited tension and spontaneous movements in intestinal strips induced by acetylcholine, GLY blocked the dopamine-induced attenuation of tension, but not the decrease of spontaneous movements in intestinal strips. The present studies suggest that $K^{+}$ channel opening suppresses intestinal movements, whereas it's blockade enhances intestinal movements in rabbit.abbit.

  • PDF

Buckling Enhancement of Column Strips with Piezoelectric Layer

  • Wang, Quan;Wang, Dajun
    • Computational Structural Engineering : An International Journal
    • /
    • 제3권1호
    • /
    • pp.49-59
    • /
    • 2003
  • This paper discusses the enhancement of the buckling capacity of column strips by use of piezoelectric layer. The analytical model for obtaining the buckling capacity of the piezoelectric coupled column with general boundary conditions modelled with different types of springs applied at the ends of the column is derived the first time. Based on this proposed model, the buckling capacity of the column strips can be accurately predicted by solving an eigenvalue problem. The computational results show the great potential of the piezoelectric materials in enhancing the buckling capacity of the column strips. The optimal locations of the piezoelectric layer for higher buckling capacity are also obtained for the columns with. standard pinned-pinned, fixed-free, and fixed-pinned structures. In addition, the buckling capacity and the increase of buckling capacity are discussed for those columns with the general boundaries as well. This research may provide a benchmark for the buckling analysis of the piezoelectric coupled strips.

  • PDF

외부 프리스트레싱과 탄소섬유판을 결합한 콘크리트 구조물 보강 (Strengthening of Concrete Structures with External Post-Tensioning and CFRP Strips)

  • 임동환;박성환;김용일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.165-168
    • /
    • 2006
  • Carbon fiber reinforced polymer(CFRP) have superior mechanical and chemical properties in comparison with conventional materials. And post-tensioning method has been used for structural reinforcement of RC structures due to easy installation and good effect of resisting capacity of structures. But the higher cost of CFRP and the loss of prestressing force with time are considered the major problems to use it. In this study, CFRP Strips and external post tensioning for rehabilitation of old concrete structures were adapted and optimal combination of these methods is considered. A total of 17 concrete members were made and tested. The types and numbers of CFRP strips and post-tensioning types were selected as major test variables. From test results, it is shown that the concrete members that post tensioned and bonded CFRP strips has a pronounced effect on the strength and deformational behavior. This present study indicates that external temporally post tensioning can reduce the amount of CFRP strips required and the combination of temporally post tensioning and CFRP strips may meet the strength and ductility requirements of old structures.

  • PDF

Comparative experimental assessment of seismic rehabilitation with CFRP strips and sheets on RC frames

  • Kakaletsis, D.J.
    • Earthquakes and Structures
    • /
    • 제10권3호
    • /
    • pp.613-628
    • /
    • 2016
  • The effectiveness of the use of modern repair schemes for the seismic retrofit of existing RC structures were assessed on a comparative experimental study of carbon fiber-reinforced polymer (CFRP) strips and sheets for the repair of reinforced concrete members of RC frames, damaged because of cyclic loading. Two virgin, single - story, one - bay, 1/3 - scale frame specimens were tested under cyclic horizontal loading, up to a drift level of 4%. Then, virgin specimens, B and F, respectively, were repaired and retested in the same way. One, specimen RB, was repaired with epoxy injections and CFRP strips and one, specimen RF, was repaired with epoxy injections and CFRP sheets. The two specimens are used to examine the differences between the structural behavior of frames repaired using CFRP strips and frames repaired using CFRP sheets. Both qualitative and quantitative conclusions, based on the observed maximum loads, loading and reloading stiffness, hysteretic energy absorption and failure mechanisms are presented and compared. The repaired frames recovered their strength, stiffness and energy dissipated reasonably. The use of CFRP sheets was found more effective than CFRP strips, due to the proper anchorage.

Experimental study on seismic behavior of RC beam-column joints retrofitted using prestressed steel strips

  • Yang, Yong;Chen, Yang;Chen, Zhan;Wang, Niannian;Yu, Yunlong
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.499-511
    • /
    • 2018
  • This paper aims to investigate the seismic performance of the prestressed steel strips retrofitted RC beam-column joints. Two series of joint specimens were conducted under compression load and reversed cyclic loading through quasi-static tests. Based on the test results, the seismic behavior of the strengthened joints specimens in terms of the failure modes, hysteresis response, bearing capacity, ductility, stiffness degradation, energy dissipation performance and damage level were focused. Moreover, the effects of the amount of the prestressed steel strips and the axial compression ratio on seismic performance of retrofitted specimens were analyzed. It was shown that the prestressed steel strips retrofitting method could significantly improve the seismic behavior of the RC joint because of the large confinement provided by prestressed steel strips in beam-column joints. The decrease of the spacing and the increase of the layer number of the prestressed steel strips could result in a better seismic performance of the retrofitted joint specimens. Moreover, increasing the axial compression ration could enhance the peak load, stiffness and the energy performance of the joint specimens. Furthermore, by comparison with the specimens reinforced with CFRP sheets, the specimens reinforced with prestressed steel strips was slightly better in seismic performance and cost-saving in material and labor. Therefore, this prestressed steel strips retrofitting method is quite helpful to enhance the seismic behavior of the RC beam-column joints with reducing the cost and engineering time.

표면매입 탄소섬유판으로 보강된 철근콘크리트 부재의 휨 거동에 관한 실험연구 (An Experimental Study on the Flexural Behavior of RC Beams Strengthened with Near-Surface-Mounted CFRP Strips)

  • 임동환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.89-96
    • /
    • 2008
  • 본 연구에서는 탄소섬유판이 표면 매입된 철근 콘크리트 보의 휨 거동 효과를 고찰하였다. 이를 위하여, 탄소섬유판이 표면 매입된 T 형 철근 콘크리트 보를 제작하여 실험을 수행하였다. 본 연구 결과, 표면매입(NSM) 탄소섬유판으로 보강된 철근콘크리트 부재의 휨 강성 및 극한강도는 섬유판으로 보강되지 않은 보에 비하여 크게 증진되며, 그 최대 증가율은 보강되지 않은 부재의 경우보다 약 247%로 나타났다. 위 철근콘크리트 부재의 파괴는 부재 길이 방향으로 섬유 소선이 풀리는 표면매입 탄소 섬유판의 파괴로 시작되며, 탄소섬유판의 파단이 이어지는 2차 파괴가 발생하였다. 표면매입 탄소섬유판은 콘크리트와의 완정한 합성거동을 유도하여 따라서 탄소섬유판을 표면에 매입하는 방식은 노후 구조물 보강방식으로 매우 효과적인 것으로 판단된다.

Finite element analysis of shear-deficient RC beams strengthened with CFRP strips/sheets

  • Lee, H.K.;Ha, S.K.;Afzal, M.
    • Structural Engineering and Mechanics
    • /
    • 제30권2호
    • /
    • pp.247-261
    • /
    • 2008
  • Performance of shear-deficient reinforced concrete (RC) beams strengthened with carbon fiber-reinforced polymer (CFRP) strips/sheets is analyzed through numerical simulations on four-point bending tests. The numerical simulations are carried out using the finite element (FE) program ABAQUS. A micromechanics-based constitutive model (Liang et al. 2006) is implemented into the FE program ABAQUS to model CFRP strips/sheets. The predicted results are compared with experiment data (Khalifa and Nanni 2002) to assess the accuracy of the proposed FE analysis approach. A series of numerical tests are conducted to investigate the influence of stirrup lay-ups on the shear strengthening performance of the CFRP strips/sheets, to illustrate the influence of the damage parameters on the microcrack density evolution in concrete, and to investigate the shear and flexural strengthening performance of CFRP strips/ sheets. It has been shown that the proposed FE analysis approach is suitable for the performance prediction of RC beams strengthened with CFRP strips/sheets.

The Parallel Measurements of Stomatal Apertures and Apoplastic pH on Guard Cells from Epidermal Strips and Intact Leaves of Commelina communis

  • Lee, Joon-Sang
    • 환경생물
    • /
    • 제20권1호
    • /
    • pp.78-84
    • /
    • 2002
  • The effects of light and darkness on stomatal aperture and guard cell apoplastic pH in the intact leaf and in the isolated epidermal strips of Commelina communis have been investigated. Stomata in the intact leaf opened wide in the light. In contrast, stomata in the isolated epidermal strips did not respond clearly to light. To eucidate the relationship between the stomatal aperture and the guard cell apoplastic pH, apoplastic pH was measured. In the light the guard cell wall of intact leaf was acidified by pH 1.9 units, falling from pH 7.3 to pH 5.4 in the first 10 minutes. On the contrary, apoplastic pH of isolated epidermal strips changed slowly from pH 7.3 to pH 6.9 at 20 min. Stomata in the intact leaf closed rapidly in the dark. On the other hand, stomata in the isolated epidermal strips failed to close in dark. There was a slow increase in apoplastic pH on transfer to the dark after incubation for 1.5 h in the light and the level observed before the experiment was regained after around 40 min. When the isolated epidermal strips were transferred to the dark, apoplastic pH maintained a uniform level of around pH 7.2-7.4. These results indicate that the mechanism of stomatal opening and closing from isolated epidermal strips and intact leaves could be different.

Numerical assessment of rectangular one- and two-way RC slabs strengthened with CFRP under impact loads

  • Mohamed Emara;Ahmed Hamoda;Jong Wan Hu
    • Computers and Concrete
    • /
    • 제31권3호
    • /
    • pp.173-184
    • /
    • 2023
  • In this study, the flexural behaviors of one- and two-way reinforced concrete (RC) slabs strengthened with carbon-fiber-reinforced polymer (CFRP) strips under impact loads were investigated. The flexural strengthening of RC slabs under simulated static monotonic loads has been comprehensively studied. However, the flexural behavior of RC slabs strengthened with CFRP strips has not been investigated extensively, particularly those conducted numerically. Nonlinear three-dimensional finite element models were developed, executed, and verified against previous experimental results, producing satisfactory models with approximately 4% error. The models were extended to a parametric study, considering three geometric parameters: the slab rectangularity ratio, CFRP strip width, and CFRP strip configuration. Finally, the main results were used to derive a new formula for predicting the total deflection of RC slabs strengthened with CFRP strips under impact loads with an error of approximately 10%. The proposed equation reflected the slab rectangularity, CFRP strip width, equivalent slab stiffness, and dropped weight. Results indicated that the use of CFRP strips enhanced the overall impact performance, the wider the CFRP width, the better the enhancement. Moreover, the application of diagonally oriented CFRP strips diminished the cracking zone compared to straight strips. Additionally, the diagonal orientation of CFRP strips was more efficient for two-way slabs while the vertical orientation was found to be better in the case of one-way slabs.

보성치과주조용합금의 생체반응에 관한 실험적연구

  • 김인철
    • 대한치과의사협회지
    • /
    • 제14권5호
    • /
    • pp.425-427
    • /
    • 1976
  • The author observed the reaction of gingval tissues which were implanted with gold, Bosung alloy and copper, the constituents of gold alloy. Pure gold and bosung alloy strips produced slight inflammation but copper had sovere inflammation. Dense fibrous fascile were formed around the gold and Bosung alloy strips on 7th day. When gold and Bosung alloy strips were implanted, eptithelial memberane were occured on 14th day, but copper strips produced eplthelial memberane on 21th day.

  • PDF