• Title/Summary/Keyword: stride length

Search Result 304, Processing Time 0.021 seconds

Change of gait pattern of a patient with ataxic gait by cerebellar infarction (소뇌 경색 환자의 임상양상에 따른 보행의 변화)

  • Hong, Haejin;Choi, Sanho;Lee, Ilsuk;Oh, Jaegun;Sung, Kang-keyng;Lee, Sangkwan
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • ■ Objectives The goal of this pilot study is to observe the change of gait pattern according to the clinical status in a patient with ataxic gait by cerebellar infarction. ■ Methods We measured the spatiotemporal gait parameters of a patient with ataxic gait four times, in which, first, the patient was not able to walk independently, second, able to walk independently, third, unable to walk independently by general tremor, and, last, able to walk independently after disappearing of general tremor. ■ Results When a patient with cerebellar ataxic gait was able to walk independently and the cerebellar tremor was disappeared, the change of gait pattern was that step and stride length decreased and total double support and stance phase increased. ■ Conclusion When different clinical characteristics were improved, the change of gait showed same pattern.

  • PDF

Change of gait pattern by ankle foot orthosis in stroke patients with foot drop (뇌졸중 환자의 단하지 보조기 착용 유무에 따른 보행 양상의 변화)

  • Oh, Jaegun;Park, Kee-eon;Jung, Byongjun;Lee, Ilsuk;Choi, Sanho;Lee, Sangkwan;Sung, Kang-keyng
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.40-48
    • /
    • 2013
  • ■ Objectives This study was designed to investigate the effects of an ankle foot orthosis(AFO) on gait of two hemiparetic stroke patients with foot drop. ■ Methods Gait of two hemiparetic stroke patients were analyzed during walking on the treadmill without or with AFO application. The spatiotemporal and center of pressure(CoP) intersection parameters of gait analysis were measured using a treadmill gait analysis system. ■ Results The AFO had positive effects on hemiparetic gait parameters; increasing cadence, increasing step length, decreasing step time, stride time, and lateral symmetry. ■ Conclusion Hemiparetic gait was improved by ankle foot orthosis.

  • PDF

The change of gait pattern according to different walking speeds in a patient with Parkinson disease (파킨슨환자의 보행 속도에 따른 보행 양상 변화)

  • Oh, Jaegun;Park, Kee-eon;Jung, Byongjun;Lee, Ilsuk;Choi, Sanho;Lee, Sangkwan;Sung, Kang-keyng
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.90-101
    • /
    • 2013
  • ■ Objectives The goal of this study was to observe the gait patterns from a patient with Parkinson disease under three different walking speeds. ■ Methods The patient walked on a treadmill and we measured gait parameters using a treadmill gait analysis system for 2 minutes. The Parkinson patients walked under three different conditions, first, at the preferred walking speed, second, at slower speed than the preferred walking speed, and, third, at faster speed than the preferred walking speed. ■ Results In terms of temporal gait parameters, as speed of treadmill increased, stance phase and total double support decreased, and swing phase increased. In terms of spatial parameters, as speed of treadmill increased, step and stride length increased. In terms of kinetic parameters, max pressure increased as speed of treadmill increased. ■ Conclusion According to different walking speeds, some gait parameters of spatiotemporal and kinetic was changed.

  • PDF

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

Utility of Gait Analysis and Functional Assessment of Prosthetic Reconstruction in Bone Tumor around the Knee (슬관절 주위에 발생한 골종양 환자에서 종양 대치물을 이용한 재건술 후 기능적 평가 및 보행 분석의 유용성)

  • Lee, Jin-Ho;Seol, Young-Jun;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.51-58
    • /
    • 2012
  • Purpose: This study attempts to know functional results and gait analysis usefulness in patients with bone tumor around knee joint tumors who underwent prosthesis knee joint reconstruction. Materials and Methods: Retrospective study was conducted with 7 patients out of 30 patients who underwent prosthesis knee joint reconstruction after wide marginal excision for bone tumor around knee in orthopedics of this hospital from 2001 to 2010. Functional assessment and gait analysis were perforemed. Results: For the SF-36 score, while 'role physical' and 'role emotional' items showed 100% (100 points) high scores individually, general health, physical function, vitality, and social function showed low scores. The mean score of MSTS was 88.1% (23.8 points [17-27]), indicating a relatively high score. For the gait analysis, mean gait velocity was 97.2 m/s, mean cadence was 105.6 step/min, mean stride length was 111.3 m, mean step length was 61.5 cm, swing phase was 39.8%cycle, stance phase was 60.1%cycle, mean single limb support was 37.1%cycle, mean double limb support was 13.0%cycle, and mean push off was 60.7%cycle. Conclusion: It is expected that prosthesis reconstruction after wide marginal excision for bone tumor around knee has relatively good functional results. Gait analysis was considered one of method which showed gait phase and assessed functional ability objectively by quantitative assessment post operative patient condition. It might help treatment and post operative rehabilitation planning with the functional assessment.

Change of Gait Pattern of Patients with Ataxic Gait by Cerebellar Infarction in Comparison to Corticospinal Tract Stroke Patients (소뇌경색 환자의 운동기능 회복에 따른 보행 척도의 변화 관찰 연구 : 피질척수로 손상환자와의 비교를 중심으로)

  • Chu, Hongmin;Lee, Young-ung;Kim, Kwang-ho;Lim, Hyeon-seo;Ryu, Ho-sun;Park, Shin-hyeok;Kim, Cheol-hyun;Sung, Kang-keyng;Lee, Sang-kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.2
    • /
    • pp.194-203
    • /
    • 2020
  • Objectives: This study aimed to compare the gait patterns of cerebellar infarction patients with those of corticospinal tract stroke patients through a follow-up of patients with ataxic gait due to cerebellar infarction and corticospinal tract stroke. Methods: We investigated two cases of patients with cerebellar infarction and two cases each of acute or chronic corticospinal tract stroke who were hospitalized at Wonkwang University Gawangju Medical Center from September 1, 2017 to February 15, 2020 based on medical records and gait analyses. The spatiotemporal gait parameters of each patient were measured three times at 2-week intervals except those of the chronic corticospinal tract stroke patients, which were measured twice at a 1-month interval. Results: Spatiotemporal gait parameters, which include velocity, cadence, step length, stride length, and single support, were consistently increased in the cerebellar infarction patients in comparison to the corticospinal tract stroke patients. The stance phase was decreased in all the patients. Conclusions: The cerebellar infarction patients' gait spatiotemporal parameters were found to consistently improve. Moreover, gait analysis can be used to effectively measure improvement of ataxic gait.

Accuracy of Electronic Pedometers to Assess Body Fatness in Obese Children and Youth (비만 어린이와 청소년들의 체지방 평가를 위한 electronic pedometer 의 정확성 분석)

  • Kim, Do-Yeon
    • Journal of Life Science
    • /
    • v.19 no.10
    • /
    • pp.1368-1373
    • /
    • 2009
  • The purpose of this study was to assess the influence of waist size on the reliability and validity of pedometers to count steps in children and youth. The participants for this study were 20 children and youth, composed of 14 Hispanic and 6 Caucasian children. Ten children and youth had waist circumferences greater than the $85^{th}$ percentile (Body Mass Index (BMI)=$28.91\pm3.07$), and 10 children and youth had waist circumferences smaller than the $50^{th}$ percentile (BMI=$18.05\pm1.55$). To examine pedometer reliability, each child completed 3 ascent and descent trials up a set of 15 stairs while wearing a Yamax SW-701 pedometer. The main effect of trials was not statistically significant for the stair ascent trials F (2, 36)=2.575 or for the descent trials F (2, 36)=0.235. The trial by group interaction was also not statistically significant. To examine the influence of waist circumference on the validity of the pedometer in counting walking steps at a self-selected walking pace, the children and youth in the two groups completed a 400-m course. The main effect on the groups was statistically significant, F (1, 18)=7.489. The main effect of counting techniques was not statistically significant, F (1, 18)=2.983 (hand-counted vs. pedometer counted). Overall, the trial and trial by group interaction comparisons for the 400-m walk were not statistically significant, suggesting that the pedometer was equally valid as a tool for assessing walking steps in high waist circumference (HWC) and low waist circumference (LWC) in children and youth.

Gait Analysis of Patients with Tumor Prosthesis around the Knee (인공 종양대치물을 이용한 사지구제술후의 보행 분석)

  • Lee, Sang-Hoon;Chung, Chin-Youb;Kim, Han-Soo;Kim, Byung-Sung;Lee, Han-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.18-25
    • /
    • 1997
  • Prosthetic replacement is one of the most common methods of reconstruction after resection of malignant tumor around the knee. Gait analysis provides a relative objective data about the gait function of patients with prosthesis. The purpose of this study was to compare the gait pattern of the patients who underwent limb salvage surgery with prosthesis for distal femur and that of patients with prosthesis for proximal tibia. This study included ten patients (4 males, 6 females, mean age 22.7 years, range 14-36) who underwent a wide resection and Kotz hinged modular reconstruction prosthesis replacement and six normal adult(Control). The site of bone tumor was the distal femur (Group 1) in six patients and proximal tibia (Group 2) in 4 patients. The follow-up period ranged from 15 to 82 months (mean : 33 months). The evaluation consisted of clinical assessment, radiographic assessment, gait analysis using VICON 370 Motion Analysis System. The gait analysis included the linear parameters such as, walking velocity, cadence, step length, stride length, stance time, swing time, single support and double support time and the three-dimensional kinematics (joint rotation angle, velocity of joint rotation) of ankle, knee, hip and pelvis in sagittal, coronal and transverse plane. For the kinetic evaluation, the moment of force (unit: Nm/kg) and power (unit: Watt/kg) of ankle, knee and hip joint in sagittal, coronal and transverse plane. In the linear parameters, cadence, velocity, step time and single support were decreased in both group 1 and group 2 compared with control. Double support decreased in group 2 compared with control significantly(p<.05). In contrast to our hypothesis, there was no significant difference between group 1 and group 2. In Kinematics, we observed significant difference (p<.05) of decreased knee flexion in loading response (G2

  • PDF

Comparison of gait ability according to types of assistive device for ankle joint of chronic hemiplegic stroke survivors (발목관절 보조 도구에 따른 만성 뇌졸중 편마비 장애인의 보행 비교)

  • Park, Dong-Chun;Jung, Jung-Hee;Kim, Won-Deuk;Son, Il-Hyun;Lee, Yang-Jin;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.2
    • /
    • pp.30-39
    • /
    • 2021
  • Background: The purpose of this study was to compare the differences in gait and mobility according to the types of assistive device for ankle joint including ankle foot orthosis (AFO), non-elastic tape, elastic tape, and high ankle shoes in chronic hemiplegic stroke survivors. Design: A cross-over design. Methods: Twelve hemiplegic stroke survivors participated in this study, and they walked under 5 different conditions including bare feet, wearing a AFO, wearing a non-elastic tape, wearing a elastic tape, and wearing a high ankle shoes. During the participants walked, the spatio-temporal gait analysis and mobility examinations were performed. For the spatio-temporal gait analysis (gait velocity and cadence, step length, stride length, and single and double leg support time) and mobility examinations, the gait mat, TUG and TUDS were used. Results: As s results, on the AFO, non-elastic tape, elastic tape, and high ankle shoes, there were significantly differences in the all spatio-temporal gait parameters, TUG, and TUDS compared to barefoot (p<0.05). In particular, all spatio-temporal gait parameters, TUG, TUDS were significantly improved with AFO compared to barefoot. TUG was significantly improved with AFO compared to non-elastic tape, TUG and TUDS were significantly improved with AFO compared to elastic tape, gait velocity was significantly improved with non-elastic tape compared to high ankle shoes, gait velocity and TUG were significantly improved with elastic tape compared to high ankle shoes, and TUDS was significantly improved with non-elastic tape compared to elastic tape. Conclusion: The AFO, non-elastic tape, elastic tape, and high ankle shoes showed a positive effect on gait and mobility compared to barefoot, and among them, wearing AFO was most effective for improving gait and mobility of chronic hemiplegic stroke survivors.

Effect of Visual Difference on Balance and Walking Capacity in Life Care of College Students (대학생의 라이프케어에서 시력 차이가 균형과 보행능력에 미치는 영향)

  • Yoon, Young-Jeoi
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.1
    • /
    • pp.191-197
    • /
    • 2021
  • This study studied the effect of visual difference on balance and walking ability in college students' life care. The study was conducted on 45 students attending H University in G City, divided into control groups (n=22, not wearing glasses and contact lenses) and experimental groups (n=23, wearing glasses and contact lenses). In not wearing glasses and contact lenses, the subjects measured visual acuity with logMAR charts, evaluated their balance ability with BIOrescue, and evaluated walking ability with G-Walk. The results of this study showed that the experimental group had statistically significantly lower vision than the control group in the visual acuity measurement(p<.01). Static balance ability was statistically significant increase in center of mass movement of the right foot in the experimental group compared to the control group(p<.05). Dynamic balance ability was statistically significantly reduce in limit of stability for groups of experiments compared to control group(p<.05). The walking ability was statistically significantly shorter on step length and stride length, swing of the experimental group compared to the control group in the right foot(p<.05). The findings showed that the visual difference in university students reduces balance and walking ability. Therefore, university students with poor visual acuity are recommended to correct of visual acuity to prevent collision and falls in their daily lives.