• 제목/요약/키워드: stress-sensor

검색결과 452건 처리시간 0.031초

Numerical study for identifying damage in open-hole composites with embedded FBG sensors and its application to experiment results

  • Yashiro, S.;Murai, K.;Okabe, T.;Takeda, N.
    • Advanced Composite Materials
    • /
    • 제16권2호
    • /
    • pp.115-134
    • /
    • 2007
  • This study proposes two new approaches for identifying damage patterns in a holed CFRP cross-ply laminate using an embedded fiber Bragg grating (FBG) sensor. It was experimentally confirmed that the reflection spectrum from the embedded FBG sensor was significantly deformed as the damage near the hole (i.e. splits, transverse cracks and delamination) extended. The damage patterns were predicted using forward analysis (a damage analysis and an optical analysis) with strain estimation and the proposed damage-identification method as well as the forward analysis only. Forward analysis with strain estimation provided the most accurate damage-pattern estimation and the highest computational efficiency. Furthermore, the proposed damage identification significantly reduced computation time with the equivalent accuracy compared to the conventional identification procedure, by using damage analysis as the initial estimation.

방향 탐지용 대공 근접 신관센서의 BPSK 송수신기 설계에 관한 연구 (Design of a BPSK Transceiver for the Direction Finding Proximity Fuze Sensor for Anti-air missiles)

  • 최재현;이석우;염경환
    • 한국군사과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.81-88
    • /
    • 2013
  • This paper describes the fundamentals, design, realization and test results of a BPSK(Bi Phase Shift Keying) transceiver for the direction finding proximity fuze sensor for anti-aircrafts or air missiles. The BPSK transceiver for the direction finding fuze sensor has been designed to detect a moving target by Doppler signal processing with the code correlation method and to distinguish direction by comparing received powers of each Doppler signal from adjacent three receiving antennas. The electrical and ESS(Environmental Stress Screening) tests of the BPSK transceiver showed satisfactory results and target detection and direction finding performances proved to be successful through dynamic operation tests by 155 mm gun firing.

유체집속효과를 이용한 폴리다이아세틸렌 센서 생성 및 크기 제어 (Formation and Size Control of Polydiacetylene Sensor Liposome Using Hydrodynamic Focusing)

  • 김강준;송시몬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2688-2691
    • /
    • 2008
  • This study addresses a microfluidic method to uniformly form diacetylene (DA) liposomes and control their size. DA liposomes are biochemical sensor materials with a unique property such that when they are polymerized to polydiacetylene (PDA) they exhibit non-fluorescent blue to fluorescent red phase transition upon chemical or thermal stress. The liposome size and distribution are important because they significantly affect the phase transition. So far, DA Liposomes, have been prepared by mixing of bulk phases leading to heterogeneous, polydisperse distribution in size. Therefore, additional post-processes are required such as sonication or membrane extrusion to obtain an appropriate size of liposomes. Here, we report a novel strategy using a microfluidic chip and hydrodynamic focusing to form DA liposomes and control their size. Preliminary results obtained by scanning electron microscope (SEM) and dynamic light scattering (DLS) show that the microfluidic strategy generates more monodispersed liposomes than a bulk method.

  • PDF

폴리다이아세틸렌을 이용한 미세유동칩 내의 온도 측정 (Temperature Measurements in a Microfluidic Chip with Polydiacetylene Sensor)

  • 장영식;류성민;송시몬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2696-2699
    • /
    • 2008
  • Microfluidic chips have been frequently utilized to perform biochemical analysis, like cell culture, because they reduce the consumptions of analytes and reagents and automate multi-step analysis processes. It is often critical to monitor temperature in a microchannel for the analyses in order to control a reaction condition of bio or chemical molecules. We propose a novel method to monitor temperature of a microchannel flow by using polydiacetylene (PDA), a conjugated polymer, that has a unique property to transform its color from visible blue to fluorescent red by thermal stress. We inject PDA sensor droplets generated by hydrodynamic instability into a microchannel with a microheater incorporated on the channel bottom. Also, we change the channel temperature by providing the different electric power to the microheater. The results show that the florescence intensity of PDA sensor droplets linearly increases in response to the flow temperature increase within a certain range.

  • PDF

AE센서를 이용한 C-GIS의 부분방전 검출에 관한 연구 (A study on the PD detecting of C-GIS using AE sensor)

  • 이현동;이용희;신양섭;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1659-1661
    • /
    • 2003
  • Recently, diagnostic techniques have been investigated to defect a partial discharge in high voltage electrical equipment. We have studied the characteristics of the acoustic partial discharge originating from the electrical defects in cubicle GIS(C-GIS). An acoustic emission(AE) sensor is used on the enclosure to detect partial discharge source because the sensor is sensitive to stress waves in its frequency range that may not be from a partial discharge source. AE signal is analyzed with phase-magnitude-frequency number(${\Phi}$-V-n) and pulse per second(PPS). Experience result has shown that the omitted acoustic signal has phase dependency and phase shift characteristic according to increase with applied voltage. These result will be helpful to the pattern recognition of the acoustic partial discharge in a C-GIS.

  • PDF

땜납이 용융 부착된 FBG 온도 센서의 특성 (Characteristics of a Solder-Clad FBG Temperature Sensor)

  • 평재협;이상배;신종덕
    • 전자공학회논문지D
    • /
    • 제36D권10호
    • /
    • pp.45-50
    • /
    • 1999
  • 본 논문에서는 열팽창 계수가 큰 땜납을 광섬유 격자 (FBG)에 용융 부착시킨 온도센서에 관한 연구 결과를 발표하고자 한다. $110^{\circ}C$ 이하의 온도에서는 브래그 파장의 변이가 0.04 $nm/^{\circ}C$로써, 땜납이 부착되지 않은 FBG보다 약 4배의 감도가 향상되었다. 그러나 $110^{\circ}C$ 이상의 온도에서는 파장 변이가 0.01 $nm/^{\circ}C$로써 땜납이 부착되자 않은 FBG와 동일한 감도가 측정되었다. 땜납을 고온에서 용융 부착하기 때문에 $110^{\circ}C$ 이하의 온도에서는 브래그 파장이 단파장 쪽으로 이동되어 나타났다. 또한, 땡납 부착 후, 땡납과 FBG의 계면에서 발생된 스트레스를 열처리 과정을 통해 이완시켜 안정된 동작을 얻을 수 있었다.

  • PDF

무구속 심탄도 모니터링 시스템을 이용한 스트레스 분석 기초연구 (Basic Study for Stress Analysis Using an Unconstrained BCG Monitoring System)

  • 노윤홍;정도운
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.118-123
    • /
    • 2011
  • Heart related diseases mainly caused by heavy work load and increasing stress in human daily life. Therefore, researches on mobile healthcare monitoring for daily life has been carried out. Notably, wearable healthcare monitoring system which has least restriction has been tried to provide an emergency alert of abnormal heart rate. In this study, we developed chair type unconstrained BCG measurement system which able to perform continuous heart status monitoring at the office and daily life in the unconstrained way. Furthermore, adaptive threshold is used to detect the heart rate from BCG signals. The HRV(heart rate variability) is calculated from heart rate interval. ECG signal measured using conventional method and BCG signal measured using unconstraint system are carried out simultaneously for the purpose of performance evaluation. From the comparison result, BCG signal shows a similar heart beat characteristic as ECG signal. This proves the possibility of practical implementation of unconstraint healthcare monitoring system. In addition, medical examination like valsalva maneuver is performed to observe the changes in HRV due to stress. By performing valsalva maneuver, heart is said to be placed under an artificial physical stress condition. Under this artificial physical stress condition, the time and frequency domain of HRV parameters are evaluated.

토크 오차 감소를 위한 디스크형 커플링을 갖는 토크센서가 내장된 로봇 관절모듈 (Joint Module with Joint Torque Sensor Having Disk-type Coupling for Torque Error Reduction)

  • 민재경;김휘수;송재복
    • 대한기계학회논문집A
    • /
    • 제40권2호
    • /
    • pp.133-138
    • /
    • 2016
  • 기존에는 로봇 말단에 6축 힘/토크 센서를 부착하여 로봇의 힘제어 및 충돌감지를 수행하였지만, 이 방법은 매우 고가이고, 로봇의 몸체에서 발생한 충돌을 감지할 수 없었다. 이의 대안으로 각 관절에 관절 토크센서를 장착하였으나, 토크 측정 시에 발생하는 다양한 오차로 인하여 실제 적용에 한계가 있었다. 이러한 문제를 해결하고자 본 연구에서는 정확한 토크 측정을 위한 관절 토크센서 및 이를 포함하는 관절모듈을 개발하였다. 제안된 관절모듈은 로봇에 인가되는 모멘트 부하를 지지하고, 조립 시 발생하는 응력을 감소시키기 위하여 토크센서에 디스크형 커플링을 첨가하여 원하는 회전토크만을 효과적으로 측정할 수 있도록 하였다. 본 논문에서는 다양한 실험을 통하여 제안한 토크센서의 성능을 검증하였다.

그래핀 기반 지능형 나노복합소재를 이용한 고감도 임팩트 페인트 센서 개발 연구 (Development of Novel Impact Paint Sensor by Using Graphene based Smart Nano Composite)

  • 김성용;박세훈;최경락;박형기;강인필
    • 한국소음진동공학회논문집
    • /
    • 제24권3호
    • /
    • pp.247-252
    • /
    • 2014
  • This paper presents a novel impact sensor which can be fabricated with smart paint made of grapheme. This smart nano paint can be easily installed on structures using a spray-on technique and that can make the sensor low cost and practical. The graphene effectively improves the piezoresistivity of the smart paint and that is available to achieve sensitive impact sensor with high gauge factor. The nano smart-paint can detect sufficient impact to cover the damaged energy range of the composite around 1~3J. The voltage outputs from the sprayed paints show fairly linear responses after signal processing. The impact makes deformation of the structure and it brings change of piezoresistivity of the paint and those converts into voltage output consequently by means of a simple signal processing system. The nano smart paint is lightweight and easily applied to the structural surface, and there is no stress concentration. The nano smart paint is expected to be a cost effective and sensitive multi-functional sensor for composites and other damage monitoring applications in the field of structural health monitoring.