• 제목/요약/키워드: strengthening length

검색결과 191건 처리시간 0.028초

아라미드섬유쉬트로 휨 보강된 RC보의 부착파괴 방지 상세에 관한 실험적 연구 (An Experimental Study to Prevent Debdonding Failure of RC Beams Strengthened by Aramid Fiber Sheets)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.84-87
    • /
    • 2004
  • Nominal flexural strength of RC members strengthened with FRP sheets is generally based on the tensile strength of composite materials obtained from coupon tests. This method is based on the assumption that bond failure does not occur until the FRP sheet reaches its rupture strength. According to the previous researches, however, bond failure often occurs before the FRP sheet reaches its rupture strength. Some attempts were made to control debonding failure by increasing the bonded length of sheet or wrapping the section around their side of the member(U-wrap). In this study, the flexural failure mechanism of RC beams strengthened with AFRP sheets with different bond lengths is investigated. Their strengthening details to prevent the premature debonding failure are also suggested and its effectiveness is verified.

  • PDF

Flexural behaviour of reinforced concrete beams strengthened with NSM CFRP prestressed prisms

  • Liang, Jiong-Feng;Yu, Deng;Xie, Shengjun;Li, Jianping
    • Structural Engineering and Mechanics
    • /
    • 제62권3호
    • /
    • pp.291-295
    • /
    • 2017
  • The behaviour of reinforced concrete beams strengthened with near surface mounted (NSM) CFRP prestressed prisms was experimentally investigated. Five RC beams were tested under four point bending. All beams were made with dimensions of 300 mm in width, 2000 mm in length and 150 in depth. The effects of presstress level of CFRP prestressed prisms and prism material type were studied. The failure mode, load capacity, deflection, CFRP strain, steel strain and ductility of the tested beams were all analyzed. The results showed that the behavior of the reinforced concrete beams strengthened with NSM CFRP prestressed prisms showed a significant increase in the load-carrying capacity and the deformation capacity. The NSM CFRP prestressed prisms strengthening technique could be considered as an effective method for repairing RC structures.

기존 실험 자료를 이용한 탄소섬유쉬트로 보강된 철근콘크리트의 보강 효과 (Retrofitted Effect of Reinforced Concrete Beams Strengthened with Carbon Fiber Sheet using Existing Test Data)

  • 이원호;임재형;박인수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.715-720
    • /
    • 1999
  • The objective of this study is to develope a new equation that can predict the flexural capacity in RC beams strengthened with Carbon Fiber Sheets(CFS). To evaluate the influence of each experimental variable, the conducted experimental test data were investigated; the variables that had an effect on the increment of the flexural capacity were the number of plys, the strengthening length, the reinforced type such as U-type after reinforcing the bottom of the beam. The previous equations were compared using the existing experimental test data, then analyzed for the merits and demerits of existing equations, using the coefficient of correlation(R). The proposed equation was derived in such a way that main parameters and their combination were obtained from the analytical study and then their coefficients were determined by regression analysis using the previous test data. As a result, the proposed equation showed the better agreement than the previous equations.

  • PDF

CFS로 횡보강된 철근콘크리트 기둥의 역학적 특성에 관한 연구 (A Study on Mechanical Characteristics of Reinforced Concrete Columns Confined with Carbon Fiber Sheet)

  • 권영웅;정성철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.743-749
    • /
    • 1999
  • Recently new rehabilitation techniques have been proposed with advanced composite materials like carbon fiber, aramid, glass fiber sheet and so forth. The purpose of this paper is to investigate the mechanical characteristics of reinforced concrete columns confined with carbon fiber sheet and evaluate the degree of their strengthening effect. For the test, the specimen size of column is 15cm$\times$15cm$\times$90cm reinforced with 4 number of main bars of 10 mm diameter, tied bars of 6 mm diameter and slenderness ratio 20. Columns were wrapped with carbon fiber sheet along the column length. It is necessary to make some assumption regarding the confinement of carbon fiber sheet to apply to reinforced concrete columns under concentric loads. The strength gain effect of columns confined with carbon fiber sheet could be predicted using the proposed equation.

  • PDF

비부착 탄소섬유판 긴장재를 갖는 철근 콘크리트 보의 휨거동 (Flexural behavior of RC beams with unbonded prestressing CFRP laminates)

  • 박종섭;박영환;정우태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.258-261
    • /
    • 2006
  • This study investigates the flexural behavior and strengthening performance of RC beams with unbonded prestressing CFRP laminates through static bending tests. The aluminum anchorage system has been developed in tins study and successfully applied to the test specimens. The prestressing level of CFRP laminatehas was 0 %, 20 %, 30% and 50 % of its tensile strength. Experimental results revealed that RC beams with unbonded prestressing CFRP laminates showed increased crack load and yield load according to the level of prestress. It has also been observed that the length of the CFRP laminates does not have significant effect on the maximum load.

  • PDF

접착 보강부재 단부에서의 응력분포에 관한 연구 (Studies on Stress Distribution at the end of the Bonded Strengtening Plate)

  • 김지선;김경원;한만엽;정영수;홍영균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.129-134
    • /
    • 1996
  • Bonding strength of reinforcing material has been recognized to be the most important factor which determines the strengthening effect and the durability of repair work. The properties of bonding layers affects the stress distribution at the end of the plate, therefore the behavior of bonding layer has to be investigated. In this study, the stress distribution at the end of the bonded plate has been tested and compared with Roberts' analysis. Shear stress and vertical normal stress at the end of strengtening plate are analysized and the effedts of bonding layer thickness, plate thickness and plate length on the bonding behavior are tested. The test results showed that thickness is one of the most important factor, which is the thinner the thickness, the smaller the maximum stress.

  • PDF

탄소섬유판으로 횡보강된 콘크리트 압축부재의 구조거동에 관한 실험적 연구 (An Experimental Study on the Structural Behavior of Reinforced Concrete Compressive Members Rehabilitated with Carbon Fiber Laminate)

  • 이희경;김성철;유성훈;김중구;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.679-684
    • /
    • 1997
  • In this study, compressive strengths of reinforced concrete compression members rehabilitated with C.F.L. were analyzed from the test. Test parameters are spacing, spliced length, and section area of rehabilitation material. Displacement, failure load were measured during test. The failure mode and ultimate load were analyzed from these measured data. Test result shows that closer spacing of C.F.L. is more effective. strengthening with 1-ply C.F.L. is more effective than that of specimen with 2-ply C.F.L. The compressive capacity of specimen spliced ($\pi$.D)/2 shows almost similar strength to that of non-spliced specimen. The ultimate load carrying capacity of specimen strengthened with C.F.L. is increased to 1.11~1.68 times of that of non-rehabilitation specimen.

  • PDF

계단식 단부 형태의 탄소섬유시트로 보강된 RC보의 구조거동 평가에 관한 실험적 연구 (Experimental Study for Evaluating Structural Behavior of RC Beams Strengthened by Tapered Ended CFRP Sheets)

  • 김영희;김희선
    • 복합신소재구조학회 논문집
    • /
    • 제3권4호
    • /
    • pp.38-44
    • /
    • 2012
  • This paper presents experimental studies aiming at evaluation of structural behaviors of RC (Reinforced Concrete) beams externally strengthened with taper ended CFRPs(Carbon Fiber Reinforced Polymers). Experiments are performed with RC beams having different numbers of CFRP layers and length of each layer. The beams are subjected to four point-bending with simply supported condition. Test results of taper ended CFRPs and non-tapered CFRPs are compared and the better strengthening effect is observed from tapered ended CFRPs.

보수.보강된 철근 콘크리트보의 구조적 거동에 관한 연구 (Structural Behavior of Strengthened RC Beams)

  • 오병환;조재열;강동옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.501-507
    • /
    • 1996
  • The final objectives of this study are to present the theoretical formula for reasonable structural analysis and practical codes on the repair/strengthening of damaged reinforced concrete structrues. For that purpose, in last year, preliminary experiments for flexure and shear of beam structure using carbon sheet and steel plate were performed, and in sequence, in this year, using aramid fiber sheet and steel plate more extensive experiment were performed. Repair for the performance of flexure and shear was focused on, and main variables were selected considering aplicablilty for practical field, such as, spacing of anchor bolt, lapping, jacking up, preloading level, and fiber difection as well as length of repairing plate and thickness. so new results from various angles are to be presented.

  • PDF

탄소섬유판으로 보강된 RC보의 휨 거동 (Flexural Behavior of RC Beams Strengthened with CFRP Strips)

  • 최기선;유영찬;박영환;박종섭;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.287-290
    • /
    • 2005
  • CFRP strips manufactured in factory are produced normally with smaller width and larger thickness than CFRP sheets. By this reason, bonding force between CFRP strips and concrete substrate is not sufficient to sustain tensile force in CFRP strips. Therefore premature debonding failure cannot be avoided when strengthening is done by simply bonding the CFRP strips. The flexural strength of RC beam strengthened with CFRP strips must be calculated based on the effective strain considering debonding failure. This paper presents test results of an experimental study conducted to evaluate the flexural strength on RC beams strengthened with CFRP strips. 7 specimens were tested with respect to bond length and amount of CFRP strips. From the test results, it was indicated that the strain of the CFRP strips achieved at debonding failure can be decreased less than 6,000$\mu$ depending on the amount of CFRP strips.

  • PDF