• 제목/요약/키워드: strengthened beam

검색결과 407건 처리시간 0.024초

유리 섬유 시트로 보강된 RC보의 휨거동 특성에 관한 연구 (A Study on the Flexural Behavior of the RC Beams Strengthened with Glass Fiber Sheets)

  • 서석영;정진환;김성도;조백순;박정용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.161-164
    • /
    • 2005
  • The flexural behavior of a strengthened beam, that is a reinforced. concrete beam with externally bonded fiber sheets, was theoretically and experimentally investigated. The effects of the amount of glass fiber sheets varying from 1 to 4 plies on the flexural capacity of the strengthened beam are also examined. The flexural rigidity of the strengthened beam was enhanced compared with RC beam. In addition, the failure mode and load-deflection relationship for the strengthened beam and the comparison of analysis with experiment are extensive investigated. Finally, the determination of the nominal moment capacity $M_n$ of the strengthened beam will be discussed

  • PDF

재하상태에 따른 철근콘크리트 보의 보강효과 (Strengthening Effect of Reinforced Concrete Beam at Different Loading Stages)

  • 이차돈;이학주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.733-739
    • /
    • 1999
  • A theoretical model for flexural behavior of strengthened reinforced concrete beam is developed based on displacement controlled nonlinear finite element method in this study. The developed model is shown to reasonably reproducing the experimental results of variously strengthened reinforced concrete beam. Parametric studies for the strengthened reinforced concrete beam at different loading stages are then performed using this model in order to assess the effect of loading stages at the time of strengthening on characteristic values of strengthened beam under flexure. It was found that depending on loading stages of a beam, deflections at yielding and at ultimate loads are more influenced than corresponding load capacities.

탄소섬유시트로 보강된 철근콘크리트 보의 휨성능 (Flexural Capacity of RC Beams Strengthened with Carbon Fiber Sheets)

  • 박현정;조백순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권3호
    • /
    • pp.177-187
    • /
    • 2004
  • 탄소섬유시트 보강보를 구성하는 재료들의 거동상태에 따라 탄성구간, 항복이전구간, 항복이후구간으로 나누어 보강보의 휨성능을 해석하였다. 보강보 후미해석의 타당성을 검증하기 위해 보강보 실험에서 측정된 항복하중, 최대하중, 휨강성 등을 비교하였다. 검증된 보강보 후미해석 방법으로부터 보강보의 구성재료가 보강보의 휨성능에 기여하는 바를 살펴보았다. 또한 보강보의 최대휨모멘트 산정에 강도설계법의 적용여부를 고찰하였다.

Seismic behavior of reinforced concrete exterior beam-column joints strengthened by ferrocement composites

  • Li, Bo;Lam, Eddie Siu-shu;Wu, Bo;Wang, Ya-yong
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.233-256
    • /
    • 2015
  • This paper presents an experimental study to assess the effectiveness of using ferrocement to strengthen deficient beam-column joints. Ferrocement is proposed to protect the joint region through replacing concrete cover. Six exterior beam-column joints, including two control specimens and four strengthened specimens, are prepared and tested under constant axial load and quasi-static cyclic loading. Two levels of axial load on column (0.2fc'Ag and 0.4fc'Ag) and two types of skeletal reinforcements in ferrocement (grid reinforcements and diagonal reinforcements) are considered as test variables. Experimental results have indicated that ferrocement as a composite material can enhance the seismic performance of deficient beam-column joints in terms of peak horizontal load, energy dissipation, stiffness and joint shear strength. Shear distortions within the joints are significantly reduced for the strengthened specimens. High axial load (0.4fc'Ag) has a detrimental effect on peak horizontal load for both control and ferrocement-strengthened specimens. Specimens strengthened by ferrocement with two types of skeletal reinforcements perform similarly. Finally, a method is proposed to predict shear strength of beam-column joints strengthened by ferrocement.

Flexural Characteristics of the Overlayed RC Beam Strengthened with Rebars, CFRP, and Steel Plate.

  • 오홍섭;심종성;이차돈;최완철;신영수;홍기섭;홍영균
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.221-229
    • /
    • 1996
  • An analytical method based on the nonlinear layered finite element method is used to simulate the load-deflection behavior of strengthened beam. Beams considered in this study are the ones strengthened either with external steel plate or Carbon Fiber Reinforced Plastic (CFRP) sheets bonded to the overlay soffit or with reinforcing rebars in the overlay. The theoretically obtained load-deflections and strains of the strengthened beam are compared to the corresponding experimental values. Comparing the approximate measures on the cumulative slips, efficiencies of the repairing techniques are evaluated. Parametric studies are, then, peformed using the developed model to investigate the effects of design variables on the overal flexural behavior of the strengthened beam. Simply supported beams under monotonically increasing symmetrical loads are considered exclusively.

  • PDF

재하상태에서 탄소섬유시트로 보강된 RC보부재의 유한요소해석 (FEM Analysis of RC Beams Strengthened with CFS on Loading Situation)

  • 송성용;;최기선;이한승;유영찬;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1181-1184
    • /
    • 2001
  • This study was performed FEM analysis of RC beams strengthened with CPS, in order to verify the effect strengthened of the loading situation. By load-deflection curve, It was not different that max capacity of RF2-L0 strengthened with CFS on the sound and RF2-L60 strengthened with on the 60% loading situation of service load. When RC beam was shortly strengthened with CFS, bond element of beam on the end was ripped off. Because stress was concentrated on bond element of beam on the end.

  • PDF

Structural behavior of steel beams strengthened with CFRP strips and cables

  • Lim, Donghwan
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.289-298
    • /
    • 2022
  • In the present study, structural behavior of steel beams strengthened with CFRP strips and cables was investigated by a series of experiments. For this purpose, two groups of experimental studies were carried out: one for the beam series strengthened only with CFRP strips and the other for the steel beam series strengthened with CFRP strips and prestressed wires. From this test, it is found that the flexural stiffness and strength of the steel beams strengthened with CFRP strips and cables were significantly improved comparing to the un-strengthened one. Three failure modes such as sudden de-bonding, splitting and rupturing of CFRP strips were observed. The ultimate tensile strains of attached CFRP strips on the steel beams were noticed in the range between 8,000με and 11,000με, and this result disclose the perfect composite reaction CFRP strips and steel beams.

Strengthening of non-seismically designed beam-column joints by ferrocement jackets with chamfers

  • Li, Bo;Lam, Eddie Siu-Shu;Cheng, Yuk-Kit;Wu, Bo;Wang, Ya-Yong
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1017-1038
    • /
    • 2015
  • This paper presents a strengthening method that involves the use of ferrocement jackets and chamfers to relocate plastic hinge for non-seismically designed reinforced concrete exterior beam-column joints. An experimental study was conducted to assess the effectiveness of the proposed strengthening method. Four half-scale beam-column joints, including one control specimen and three strengthened specimens, were prepared and tested under quasi-static cyclic loading. Strengthening schemes include ferrocement jackets with or without skeleton reinforcements and one or two chamfers. Experimental results have indicated that the proposed strengthening method is effective to move plastic hinge from the joint to the beam and enhance seismic performance of beam-column joints. Shear stress and distortion within the joint region are also reduced significantly in strengthened specimens. Skeleton reinforcements in ferrocement provide limited improvement, except on crack control. Specimen strengthened by ferrocement jackets with one chamfer exhibits slight decrease in peak strength and energy dissipation but with increase in ductility as compared with that of two chamfers. Finally, a method for estimating moment capacity at beam-column interface for strengthened specimen is developed. The proposed method gives reasonable prediction and can ensure formation of plastic hinge at predetermined location in the beam.

An experimental investigation of the flexural strengthening of preloaded self-compacted RC beams using CFRP sheets and laminates composites

  • Lattif, Youssef;Hamdy, Osman
    • Advances in concrete construction
    • /
    • 제13권4호
    • /
    • pp.307-313
    • /
    • 2022
  • This paper performs an experimental study on the flexural behavior of preloaded reinforced self-compacted concrete beams strengthened with carbon fiber reinforced polymers CFRP. A group of six preloaded strengthened beams was investigated along with one unstrengthened beam used as a reference beam RB. All beams have the same dimensions and reinforcement details: three beams are strengthened with CFRP laminates against flexural failure and three beams are strengthened with CFRP sheets. For simulating actual conditions, the beams are loaded before strengthening. Then, after strengthening, the beams are tested for flexural strength using 4-point loads where cracked and ultimate load and failure mode, along with load-deflection relation are recorded. To study the different configurations of strengthening, one layer, two layers, and U-wrap formation of laminates and sheets are considered. The results show that strengthing the RC beams using CFRP is an effective method to increase the beam's capacity by 47% up to 153% where deflection is reduced by 5%-80%. So, the beams strengthened with CFRP laminates have higher load capacity and lower ductility in comparison with the beams strengthened with CFRP sheets.

Effect of Anchorage Number on Behavior of Reinforced Concrete Beams Strengthened with Glass Fiber Plates

  • Kaya, Mustafa;Kankal, Zeynel Cagdas
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.415-425
    • /
    • 2015
  • Reinforced concrete beams with insufficient shear reinforcement were strengthened using glass fiber reinforced polymer (GFRP) plates. In the study, the effect of the number of bolts on the load capacity, energy dissipation, and stiffness of reinforced concrete beams were investigated by using anchor bolt of different numbers. Three strengthened with GFRP specimens, one flexural reference specimen designed in accordance to Regulation on Buildings Constructed in Disaster Areas rules, and one shear reinforcement insufficient reference specimen was tested. Anchorage was made on the surfaces of the beams in strengthened specimens using 2, 3 and 4 bolts respectively. All beams were tested under monotonic loads. Results obtained from the tests of strengthened concrete beams were compared with the result of good flexural reference specimen. The beam in which 4 bolts were used in adhering GFRP plates on beam surfaces carried approximately equal loads with the beam named as a flexural reference. The amount of energy dissipated by strengthened DE5 specimen was 96 % of the amount of energy dissipated by DE1 reference specimen. Strengthened DE5 specimen initial stiffness equal to DE1 reference specimen initial stiffness, but strengthened DE5 specimen yield stiffness about 4 % lower than DE1 reference specimen yield stiffness. Also, DE5 specimen exhibited ductile behavior and was fractured due to bending fracture. Upon the increase of the number of anchorages used in a strengthening collapsing manner of test specimens changed and load capacity and ductility thereof increased.