• Title/Summary/Keyword: strength meter

Search Result 185, Processing Time 0.029 seconds

Development of Intelligent Compaction System for Efficient Quality Control (효율적 품질관리를 위한 지능형 다짐 시스템 개발)

  • Lee, Soomin;Park, Sangil;Lee, Riho;Seo, Jongwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.751-760
    • /
    • 2018
  • Currently, the quality measurement of the work is carried out by the supervisor's visual inspection, as the workers individually judge the number of resolutions, thickness, speed and vibration. After work, we are conducting follow-up work through traditional spot test, which is less representative. Therefore, it is impossible to check the results of the resolution, and there is always the possibility that problems will arise due to poor construction. This study demonstrates the feasibility of using the continuous compaction strength measurement method by comparing the continuous compaction strength measurement method and the conventional compaction strength measurement method after performing the compaction in the actual field scale in various test conditions. The validity is verified by analyzing the Compaction Meter Value of an Intelligent Compaction roller composed of a Global Positioning System and an accelerometer, Based on the proven results, a full range of quality can be confirmed without a single test. The quality confirmation is visualized in the compaction control program developed in this study, This enables the field manager to perform real-time quality monitoring at the same time as compaction.

Indices for Quality Evaluation by Physicochemical and Chemoenzymatic Method in Red seabream, Pagrus major (물리 및 효소화학적 방법에 의한 참돔, Pagrus major의 품질판정 지표 설정)

  • 심길보;배진한;정호진;여해경;김태진;조영제
    • Journal of Aquaculture
    • /
    • v.17 no.3
    • /
    • pp.228-232
    • /
    • 2004
  • This study evaluates red seabream quality using physicochemical and chemoenzymatic indices. Breaking strength was correlated with moisture content and lipid content of red seabram by a precedent experiment. Moisture content (X$_1$), lipid content (X$_2$) and breaking strength (Y) were optimized with multiple regression as, Y= -2.53539+0.05544X$_1$-0.00161X$_2$. To test the equation, red seabream (n=13) were randomly purchased and measured moisture content, lipid content and breaking strength. The calculated breaking strength using the equation was similar to breaking strength measured using Rheo meter. Adenylate energy charge (AEC), a general biochemical index of stress, values of all sample were higher than 0.8 expect two fish. Fish's condition was a good. The equation developed in this study predicts breaking strength with moisture and lipid content measured. Moreover the equation may be used in grading cultured red seabream with calculated breaking strength. Grade according to breaking strength, when it came to over 1.4 kg, was measured as high grade; when it came to below 1.2 kg, was measured as low grade. Grade according to AEC, when it came to over 0.8, was measured as high grade.

Constraints of English Poetic Meter (영시 정형율의 제약들 - Iambic을 중심으로 -)

  • Sohn Ilkwon
    • MALSORI
    • /
    • no.42
    • /
    • pp.71-88
    • /
    • 2001
  • This study is on the constraints of English Poetic Meter. In English poems, the metrical pattern doesn't always match the linguistic stress on the lines. These mismatches are found differently among the poets. The peaks mismatched with the weak metrical position are divided into the two ways according as they are adjacent to the boundary of a phonological domain or not. PAF and $^*UV$] are suggested for the mismatched peak which are not adjacent to the boundary of a phonological domain ; $^*Peak$] and BT for the mismatched peak which are adjacent to the boundary of a phonological domain. For the lexical stress mismatched with the weak metrical position, $^*W{\;}{\Rightarrow}{\;}Strength$ is set up by the concept of the strong syllable. $MPS{\;}{\Rightarrow}{\;}\Phi_{max}$ for the metrical position size can replace the resolution which is used to control the number of syllables in English poems. These constraints show the different hierarchies among the poets.

  • PDF

Shear Cracking of Prestressed Girders with High Strength Concrete

  • Labib, Emad L.;Mo, Y.L.;Hsu, Thomas T.C.
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.1
    • /
    • pp.71-78
    • /
    • 2013
  • Prestressed concrete (PC) is the predominant material in highway bridge construction. The use of high-strength concrete has gained wide acceptance in the PC industry. The main target in the highway industry is to increase the durability and the life-span of bridges. Cracking of elements is one aspect which affects durability. Recently, nine 7.62 meter long PC I-beams made with different concrete strength were designed according to a simple, semi-empirical equation developed at the University of Houston (UH) (Laskar et al., ACI Journal 107(3): 330-339, 2010). The UH Method is a function of shear span-to-depth ratio (a/d), concrete strength $\sqrt{f^{\prime}_c}$, web area $b_wd$, and amount of transverse steel. Based on testing these girders, the shear cracking strength of girders with different concrete strength and different shear span-to-depth ratio was investigated and compared to the available approaches in current codes such as ACI 318-11 (2011) and AASHTO LRFD Specifications (2010).

A Study on the Effect of Admixture Types and Replacement Ratio on Hydration Heat Reduction of High-Strength Concrete (고강도 콘크리트의 수화열 저감에 미치는 혼화재 종류 및 대체율의 영향에 관한 연구)

  • Kim, Moo-Han;Choi, Se-Jin;Oh, Si-Duk;Kim, Yong-Ro;Lee, Jong-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.145-150
    • /
    • 2002
  • The hydration of cement paste occurs when the cement is miked with water. During the hydration, hydration heat causes the thermal stress depending on the site of concrete and the cement content. Especially in the high-strength concrete, we must give care to the concrete due to its large cement content. In this study conduction calorimeter and concrete insulation hydration heat meter were used to investigation the hydration heat characteristics of cement and concrete. To reduce hydration heat of high-strength concrete, several types of replacement of fly-ash and blast-furnace slag powder were used in this experiment. As a result of this study, it was found that hydration heat of high-strength concrete was reduced by replacement of fly-ash and blast-furnace slag powder. In case of high-strength concrete using blast-furnace slag powder, the max-heat arrival time was delayed but an effect of heat reduction was lower than a case of high-strength concrete using fly-ash, because it was considered that the heat-dependence property of blast-furnace slag powder was higher than that of fly-ash.

A STUDY ON FRACTURE STRENGTH AND COLOR BY THE DESIGN OF METAL COPING IN CERAMO METAL CROWN (내부금속관 형태에 따른 도재전장금관의 파절강도와 도재색조에 관한 연구)

  • Lee Myung-Ho;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.103-124
    • /
    • 1992
  • The purpose of this study was to investigate the effect on the fracture strength and color of ceramic by the design of the metal coping in ceramo metal crown. In this study, four types of ceramic crowns were made for fracture strength : standard ceramo metal crown, collariess ceramo metal crown, modified ceramo metal crown, and ceramic jacket crown. And three types of disk formed-specimens were made to compare the dentin shade owing to aluminous opaque powder and palladium alloy. Fracture strength was measured by universal testing machine(Instron Co. Ltd., U.S.A) and color was measured by color and color difference meter(Yasuda Seiki Seisakusho, Ltd., Japan). The results were as follows : 1. The fracture strength of ceramic was affected significantly by the design of metal coping in ceramo metal crown. The mean fracture strength(192.0 Kg) of standard ceramo metal crown was about 1.7 times higher than that(111.5 Kg) of collarless ceramo metal crown, and about 2.8 times higher than that(67.8 Kg) of ceramic jacket crown. 2. Modified ceramo metal crown that has metal band in the labio cervical had the lowest fracture strength. 3. Lightness, yellowness and redness of the dentin fired were decreased by the metal coping.

  • PDF

The Pilot Study on the Immediate Effects of Graston Technique for Lower Extremity Range of Motion, Muscle Strength, Walking Ability in Hemiplegic Patients (그라스톤을 이용한 연부조직가동술이 편마비 환자의 하지 관절 가동범위, 근력, 보행 능력에 미치는 즉각적인 영향에 관한 예비 연구)

  • Choi, Yul-jung;Sim, Hyun-po;Lee, Jun-yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.25 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Background: The purpose of this study was to investigate the effects of Graston technique for lower extremity range of motion (ROM), muscle strength, walking ability in hemiplegia patients. Methods: Twelve subjects participated in this study. The ROM of the knee extension was measured by 90-90 straight leg raise test, the hamstring and quadriceps muscle strength was collected by utilizing a handheld dynamometer. In addition walking speed was evaluated by 10 meter walking test. The group was applied intervention using a Graston instrument for one minute. After intervention, immediate effect was assessed. The significant level was set at ${\alpha}=.05$. Results: The ROM of the knee extension, quadriceps muscle strength and walking speed were significantly increased. Hamstring muscle strength was significantly reduced. Conclusion: The results of this study suggest that Graston instrument technique has the effect of instantaneously flexibility the muscles, and the muscle applied with the technique has weakened, while the muscle of the opposite side has increased the muscle strength. In addition, the muscle flexibility and the walking speed have increased.

Estimation of Fish School Abundance by Using an Echo Sounder in an Artificial Reef Area (어군탐지기를 이용한 인공어초 주변의 어군량 추정)

  • HWANG Doo Jin;PARK Ju Sam;LEE Yoo Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.3
    • /
    • pp.249-254
    • /
    • 2004
  • The hydro-acoustic method is widely used for estimating biomass and distribution of fisheries resources along the coast and in the ocean. High costs and time are necessary to construct systems for this method and to initially educate specialists. It has been used in fisheries of advanced nations like Japan and Norway, because it is more efficient than other methods. In order to research the behavior of fish around an artificial reef using an echo sounder, volume backscattering strength (SV) and fish per cubic meter (FPCM) of darkbanded rockfish around the model artificial reef in a water tank were measured. Moreover, behavior of fish was observed in an adjacent artificial reef, which was constructed at Tongyeong marine ranching area. Following that, an acoustics survey was conducted at Mirukdo around the Tongyeong marine ranching area, in order to understand the spatial distribution and strength of fisheries resources. Very high patches of fish were found in a wide area around the artificial reef. It is thought that an approaching fish school around the artificial reef can be measured accurately by using an echo sounder of high resolution. Moreover, use of other monitoring methods like of diving or ROV simultaneous with an echo sounder is required in order to grasp the species and ecology of fish inhabiting the area around the artificial reef.

Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance (비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향)

  • Lee, Dong-Woo;Jeong, Mo-Beom
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.1
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.

The Effect of Sit to Stand Training Combined with Ultrasound on Spasticity, Muscle Strength and Gait Speed in Patients with Stroke

  • Jung, Kyoungsim;In, Taesung
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.344-349
    • /
    • 2022
  • Objective: The purpose of the present study was to determine whether sit to stand training combined with ultrasound improves the spasticity, muscle strength and gait speed in stroke patients Design: Randomized controlled study Methods: The current study included 40 stroke patients, who were randomly divided into two groups: the sit to stand training with ultrasound (USTS) group (n=20) and the sit to stand training (STS) group (n=20). All the participants underwent 30 sessions of STS training (thirty minutes, five days per week for six weeks). Additionally, the USTS group received ultrasound therapy. The present study evaluated the spasticity of ankle plantar-flexors by the composite spasticity score. The muscle strength and gait speed were evaluated using the handheld dynamometer and the 10-meter walk test, respectively. Results: The USTS group and the STS group showed significant improvements in spasticity, muscle strength and gait speed after the intervention (p<0.05). Significant improvement in the spasticity, muscle strength, and gait speed were observed in the USTS group compared to the control group (p < 0.05). Conclusions: The results of the current study imply that sit to stand training combined with ultrasound is a beneficial and effective therapeutic modality that can be employed to improve the spasticity, muscle strength and gait speed in stroke patients.