• Title/Summary/Keyword: street lamp

Search Result 59, Processing Time 0.036 seconds

The Field Situation Analysis of Street Lamp Which is Established in The Urban (도심에 설치된 가로등설비의 현장실태 분석)

  • 한운기;한기붕;길형준;최충석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.117-122
    • /
    • 2003
  • Street light facilities, which are easily accessible, can be in danger of electric shock when water percolates the facilities especially in summer. In case deteriorated facilities are not checked regularly, they can cause accidents such as electric shock. We should consider regional characteristics to prevent this kind of accidents. In this paper, we analyzed the problems according to the facilities through the research on the actual conditions. We also analyzed the facilities by region and the standards by the conditions.

  • PDF

The development of the HID Electronic Ballast for the street lamp with the leakage Current detection and circuit breaker function (누전검출 및 차단기능을 가진 가로등용 HID 전자식 안정기 개발)

  • Park, Chong-Yeun;Lim, Byoung-Noh;Choi, Won-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.99-102
    • /
    • 2006
  • We developed the electronic ballast for the street HID lames with the leakage current detection and circuit breaker function. By detecting the leakage current and breaking the system we are protected from the electric shock and the ballast is safe from the electric damage at the time of the continuous reignition state.

  • PDF

A Study on the Characteristic of Electric-Shock Mechanism in the Water (수중에서의 감전 메카니즘 특성에 관한 연구)

  • Do, Bum-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.111-118
    • /
    • 2007
  • Recently electric shock accidents constantly occurs caused by the street lamps. Especially the chance of electric shock accident is high when the street lamp submerges by heavy rainfall. Electric shock accident occurs mostly on the low voltage facilities of 220V, but the awareness of its danger is insufficient. The electric shock accident by street lamp voltage of 220V is very dangerous because it is installed in the street which is easily in contact with people. But there are insufficient investigation concerning the affect to hwnan body of underwater electric potential distribution as the distance changes from the leakage object in case of short circuit. In this thesis, the analysis will be made on the affect of underwater Earth leakage to human body and electric potential distribution in underwater, and to draw a comparison between electric shock channel and electric shock mechanism by experimenting on the affect to human body of underwater electric shock as the distance changes from the leakage object.

Development of the LED Street Lamp by using Wired and Wireless Remote Control System (유무선 원격제어장치를 이용한 LED 가로등 제어 시스템 구현)

  • Park, Sung-Wook;Ohm, Woo-Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.235-242
    • /
    • 2014
  • LED lighting control technique is one of the ongoing research areas for efficient management of LED lighting. In this paper, we design and implementation of LED street lighting remote control system which have a wired and wireless communication function for LED street lighting remote control. The implemented system can automatically dimming and individual(or consolidated) LED street lighting via RS-485/422 or Wi-Fi. In experimental results, the implemented remote control system was satisfactory for all of the desired functions.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

Study on Simulation Design of Light Emitting Diode Luminaires for 100 W Safety Street Lighting

  • Shin, Ik-Tae;Lee, Se-Il;Yang, Jong-Kyoung;Park, Dae-Hee;Lee, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.3
    • /
    • pp.138-144
    • /
    • 2010
  • Optical analysis is necessary to optimize light emitting diode (LED) safety street lighting. In this study, optical analysis was conducted for 100 W LED safety street lighting. Experimental research on such a single LED was the first undertaken. Simulation modeling based on the optical properties of the single LED has compared between average road illuminances and has them analyzed with Korean Industrial Standards for LED safety street lighting (KS C7658:2009). The simulation results demonstrated that the illumination performance (average road illuminance) was 75.3 lx at a height of 4 m and an area of $32\;m^2$, 45.25 lx at a height of 5 m and an area of $72\;m^2$, and 30.05 lx at a height of 6 m and an area of $128\;m^2$. 100 W safety street lighting (model CE180-ST-OS) designed by simulation was also compared between product and 100 W simulation modeling, and error rates averaged 5.6%. The 100 W LED safety street lighting base designed in simulation modeling was proven by comparison experiments. Through the simulations and the corresponding analysis, it was found that the tested 100 W LED safety street lamp had reasonable performance. The design method for LED safety street lamps has been summarized based on the optical analysis.

Energy and Safety Efficient LED Street-light Control System Based on Ubiquitous Sensor Network (USN 기반의 에너지 및 안전성 효율적인 LED 가로등 제어 시스템)

  • Cho, Myeon-gyun;Kim, Shik;Yang, Woo Suk
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.6 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • LEDs are becoming the most suitable candidate replacing traditional fluorescent street-light lamps because of its energy efficiency and high brightness. Furthermore, most countries are urging to pursue energy savings in conjunction with IT and sensor network. In order to conserve energy of LED lamp and ensure the safety of pedestrian, we propose a new smart control method for LED light system based on USN using compound sensors, such as illuminance, motion, temperature and humidity sensor. An elaborate simulation shows that the proposed system with a smart control based switching can reduce the energy by 40%, compared to the previous street-light system with a fixed time based switching.

Green Panel Lighting Fixture of LED Lamp for Aquaculture and Marine Aquanautics (수중 양식과 탐사를 위한 LED 녹색평판조명램프)

  • Soh, Hyun-Jun;Kang, Sang-Taek;Kim, Jae-Gyun;Soh, Dea-Wha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.730-733
    • /
    • 2010
  • The Green Lamp Fixture (GLF) of LED prepared with thin panel structure was investigated for illumination of street lamps and other lighting system uses, which was also very useful to aquaculture and aquafarm lighting uses, or fish luring lights and marine aquanautics of aquamarinautics (aquamarine+aquanautics) uses, etc. In the case of fish luring lights, it was verified that the fish luring of Green Lamp Fixture of LED was very effective for phototaxis movement and ecological community promotion to the micro-living things of organisms and the small fries and fishes, like as 'crowding together'. For the aquaculture lightings, it was also very excellent in waterproof and heat-sink properties, photosynthetic growing of algae and micro-organisms, water-weeds and seaweeds living underwater.

  • PDF

The Analysis of Potential Distribution for Submerged Electrical Fittings in an Underground Shopping Street (지하상가 침수 시 전기설비 전위분포 해석)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2072-2073
    • /
    • 2007
  • This paper describes the analysis of potential distribution and leakage current magnitude around the electrical fittings submerged in an underground shopping street. In the experiment, a couple of electrical utilities(outlet, fluorescent lamp) were submerged in a concrete water bath. The experimental results are expected to be utilized for the risk assessment and the safety countermeasure against the electric shock.

  • PDF