• Title/Summary/Keyword: stream water treatment

Search Result 322, Processing Time 0.025 seconds

Study on the characterization of dissolved organic matters in Nakdong River (낙동강의 용존 유기물질 특성에 관한 연구)

  • Heo, Seong-Nam;Park, Jeong-Min;Im, Tae-Hyo;Shin, Chan-Ki
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.13-26
    • /
    • 2007
  • Changes in the characteristics of dissolved organic matter was studied at selected stations in the Nakdong river basin using physical and chemical methods. Characteristics of dissolved organic matters were analysed and assessed. Production of disinfection byproducts were also investigated. 1. Result of relatedness study among each items of analyses showed that relatedness on BOD values were highest with cattle excrement treatment facilities where there is no synthetic organic materials and relatedness on $COD_{Mn}$ were highest at the mainstream Nakdong river. In case of $COD_{Cr}$ (which has more oxidative power than $COD_{Mn}$), the values were higher in the sidestreams indicating the higher content of recalcitrant compounds. The relatedness values for the $UV_{254}$ also showed higher values in the sidestreams and treatment facilities than mainstream indicating the presence of organic aromatic compounds. 2. Ratio of DOC on total organic carbon were higher in the mainstream which is attributable to the influent particulate organic materials produced by agricultural activities. The values were 10-15% higher in the mainstream compared with sidestreams. 3. Result of biodegradability test indicate that concentrations of recalcitrant DOC were higher in the sidestreams than in the mainstream. The values of recalcitrant DOC were higher with the forest stream indicating the effect of soil oriented humic substances. 4. Result of THM production test carried out at 10 stations in the Nakdong river show that $CHCl_3$ was detected with the highest value and the value was highest at Waekwan station.

Biodegradation of Cutting Oil by Pseudomonas aeruginosa KS47 (Pseudomonas aeruginosa KS47에 의한 절삭유의 생물학적 분해)

  • Kim, Lan-Hee;Lee, Sang-Seob
    • Korean Journal of Microbiology
    • /
    • v.44 no.1
    • /
    • pp.22-28
    • /
    • 2008
  • Cutting oils are emulsionable fluids widely used in metal working processes. Their composition is mineral oil, water, and additives (fatty acids, surfactants, biocides, etc.) generating a toxic waste after a long use. Cutting oils also affect colour, taste and odour of water, making it undesirable for domestic and industrial uses. In these days, conventional treatment methods as evaporation, membrane separation or chemical separation have major disadvantages since they generate a concentrated stream that is more harmful than the original waste. In this study, our purpose is to reduce cutting oils by using biological treatment. Eighty one strains were isolated from cutting waste oil of industrial waste water sludge under aerobic conditions. Among these strains, KS47, which removed 90.4% cutting oil in 48 hr, was obtained by screening test under aerobic conditions(pH 7, $28^{\circ}C$). KS47 was identified as Pseudomonas aeruginosa according to morphological, physiological and biochemical properties, 16S rDNA sequence, and fatty acid analysis. P. aeruginosa KS47 could utilize cutting oil as carbon source. In batch test, we obtained optimal degradation conditions(1.5 g/L cell concentration, pH 7, and temperature $30^{\circ}C$). Under the optimal conditions, 1,060 mg/L cutting oil was removed 83.7% (74.1 mg/L/hr).

Runoff Characteristics and Non-point Source Pollution Loads from Cheongyang-Hongseong Road (청양-홍성간 도로에서의 강우 시 비점오염 유출특성 및 오염부하량 분석)

  • Lee, Chun-Won;Kang, Seon-Hong;Ahn, Tae-Woong;Yang, Joo-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.265-274
    • /
    • 2011
  • Nowadays, the importance of non-point source pollution treatment is being emphasized. Especially, the easy runoff characteristic of highly concentrated pollutants in the roads makes the circumstance more complicated due to impermeability of roads. When the pollutants flow into steam it could make water quality in stream worse and it also causes a bad influence in the aquatic ecosystem because the effluents of rainfall-runoff may contain indecomposable materials like oil and heavy metals. Therefore, we tried to figure out the property of non-point source pollution when it is raining and carried out an assessment for the property of runoff for non-point source pollution and EMC (Event Mean Concentrations) of the essential pollutants during this study. As the result of the study, the EMC was BOD 5.2~21.7 mg/L, COD 7.5~35.4 mg/L, TSS 71.5~466.1 mg/L, T-N 0.682~1.789 mg/L and T-P 0.174~0.378 mg/L, respectively. The decreasing rate of non-point pollutant in Chungyang-Hongsung road indicates the maximum decrease of 80% until 5 mm of rainfall based on SS concentration; by the rainy time within 20~30 minutes, the decreasing rate of SS concentration was shown as 88.0~97.6%. Therefore it was concluded that it seems to be possibly control non-point pollutants if we install equipments to treat non-point pollutants with holding capacity of 30 min. It is supposed that the result of this study could be used for non-point pollutants treatment of roads in Chungyang-Hongsung area. We also want to systematically study and consistently prepare the efficient management of runoff from non-point source pollution and pollutant loading because the characteristics of non-point source pollution runoff changes depending on different characteristics and situations of roads and rainfall.

Tubular Alumina Microfiltration Membrane System with Periodic N2-back-flushing for Water Treatment

  • Park, Jin-Yong;Park, Seong-Jae;Kim, Geun-Su
    • Korean Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.26-32
    • /
    • 2008
  • The Gongji stream water of Chuncheon city was filtrated by 2 kinds of tubular alumina ceramic MF membranes with periodic $N_2$-back-flushing. $N_2$-back-flushing time (BT) was changed in $0{\sim}50$ sec at fixed filtration time (FT), or back-flushing period, of 4 min for NCMT-5231 membrane ($0.05\;{\mu}m$). Then, FT was changed in $0{\sim}32$ min at fixed BT of 40 sec for NCMT-7231 $0.1{\mu}m)$). In the viewpoints of total permeate volume ($V_T$), dimensionless permeate flux ($J/J_0$) and resistance of membrane fouling ($R_f$), the optimal $N_2$-BT was 50 sec, which was the longest BT, at 4 min FT for NCMT-5231. It means the longest BT was the most effective to minimize the membrane fouling, and we could acquire the most $V_T$. But the optimal FT for NCMT-7231 was 16 min in the viewpoint of $V_T$, and was 8 min in the viewpoints of $J/J_0$ and $R_f$ at fixed BT of 40 sec. The rejection rates were excellent as $80.6{\sim}96.6\;%$ for turbidity, $35.2{\sim}58.4%$ for $NH_3$-N, $16.3{\sim}45.2%$ for T-P and $16.3{\sim}45.2%$ for $COD_{Mn}$. However, the rejection rate of T-N was very low as $2.7{\sim}13.4%$ and it of TDS below 6.1%.

Analysis of water purification in the FWS wetland for Agreculture Area (농업지역 내 FWS 인공습지의 수질정화효율 분석)

  • Kang, Chang-Guk;Maniquiz, Marla C.;Son, Young-Gyu;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.12 no.3
    • /
    • pp.39-47
    • /
    • 2010
  • Annually, the scale of agricultural areas in Korea were being reduced as the lands were converted to other land uses. While the rate of productivity were either being maintained or increased, the pollution load from these areas were still greater in magnitude. Although the levels of pollutant concentration released in the agricultural watersheds were minimal, the combined quantities mostly from diffuse sources were high. As a consequence, the Ministry of Environment (MOE) in Korea adopted the use of free water surface (FWS) flow constructed wetlands to reduce the pollutant loadings emitted from agricultural watersheds for the improvement of water quality and protection of aquatic ecosystems. In this study, a constructed wetland treating stream water in an agricultural watershed was monitored since April 2009 subsequent to its completion in December 2008. Satisfactory performance was achieved for TSS, BOD and TP with 26%, 28% and 39% pollutant removal rates, respectively. In addition, the effluent water quality was improved and achieved compliance the national water quality criteria. Results of this study can be useful to establish design parameters and employ proper removal techniques of similar natural treatment systems for future implementation in the country.

Epidemiological Studios on Clonorchis sinensis Infection along the Nam-river in Gyeongnam Province, Korea (남강유역 간흡충감염의 역학적 조사연구)

  • 배경훈;안영겸
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.116-186
    • /
    • 1983
  • An epidemiological study on Clonorchis sinensis infection along the Nam-river (total length ; 186km) flowing in Gyeongsang-nam-do, southern part of Korea, was carried out. Formalin-ether concentration technique and Stoll's egg counting method were employed to figure out the prevalence of C. sinensis infection. For the detection of cercariae from Parafossarulus sp., the snail host of C. sinensis, each snail was placed in aerated tap water, and examined for expelled cercariae. For observing the metacercariae the fresh water fish favorably eaten in raw conditions wore prepared by means of pressing the muscles between two slide glasses and/or by digesting them with artificial gastric juice. The fresh water fish were fed to the rabbits to get the worms and to identify the morphology of adult C. sinensis. The results are summarized as follows: 1. Overall Prevalence of C. sinensis infection was 38.75 from 5,291 examinees; 44.15 (1,408 out of 3,196) in male and 30.4% (637 out of 2,095) in female. 2. The prevalence rates were 42.0% at the upper stream, 41.2% around the vicinity of Jinyanglake, 34.2% at Jinju city, 34.2% at middle stream and 40.3% at down stream regions, respectively. 3. By age, the highest positive rate (53.4∼54.3%) was observed in 30 to 59 years of age. In this age group, the rate in males was 59.7∼62.2%, and in females 42.2∼44.4%, In the age group of less than 19 years it was 7.5∼20.9%. 4. By social strata, the positive rate was 16.5% in the primary school children, 22.6% in school students, 46.2% in teachers and local officers and 49.6% in the general inhabitants. 5. The quantitative examinations with the stool collected from clonorchiasis cases revealed that the light infection (less than 4,000/EPG) was 53.6%, moderate infection (4,001∼10,000 /EPG) 30.3% and heavy infection (more than 10,001/EPG) 16.1%, respectively. More than half of total cases examined were light infection, and 73.2% of female examinees were lightly infected with this cuke. 6. The average value of EPG was 4,963 (male, 6,057; female, 2,557 and the highest value was obtained from the age group of 30 to 59 years (5,240∼6,454). 7. The prevalence of Metagonimus yokogawai infection in humans was 5.5%, and 89.8% of metagonimiasis cases wore double-infected arith C. sinensis. The highest prevalence rate was observed in Jinju city (11.2%). 8. Total of 5,005 Parafossarulus sp., the snail intermediate host of C. sinensis, were examined for the detection of cercariae. The cercarial expulsion rate was 0.34%, and the snails collected in Jin-yang-lake side and in the down stream expelled mainly the cercariae of C, sinensis. 9. About 788 cercariaejday (range: 127∼1,503) were expelled daily from a snail naturally infected with C. sinensis. The snails which released more than 1,000 cercariae/day were 30.8% out of total collected. A snail uniquely released 5,840 cercariae/day in this study. 10. The other trematode cercariae besides C. sinensis were also detected, and the rates out of total snails were the cercariae of Losogenes liberum 6.71%, Cyathocotyle orientalis 0.26%, Notocotylus attenuatus 2.52% and Mucobucaris 0.54%, 11. Ten out of 18 species of fresh water fish caught along the river harbored the metacercariae of C, sinensis. The highest rate of metacercarial infection in fish was detected in Pseudorasbora larva (85.9%). The fish mainly eaten by the inhabitants along the Nam-river, and the metacercarial infection rates were: Zacco platypus 8.0%, Hemibarbus sp. 18.2∼26.7%, Gnathepcgcn sp. 37.5%, Ischikauia steenackeri 42.9% and Pseudogobio esocinus 16.7%. 12. Out of 36 P. larva, the number of metacercariae were about 109 (ranEe; 18∼446) per fish and 27 per gram of flesh. The fish caught in spring harbored the highest number of metacercariae. As indicated above, the prevalence of C. sinensis infection in the inhabitants residing around the Nam-river was relatively high. The farther toward the upper stream areas, the higher was the positive rate of C. sinensis infection, and most of clonorchiasis cases were lightly infected. The snail hosts of C. sinensis distributed all around the Nam-river. Several species of freshwater fish were infected with the metacercariae of C. sinensis and the infection rates were relatively high. To prevent C. sinensis infection in the endemic areas, the effective health education system is suggested as a control measure, although mass treatment is also expected to be useful, using chemotherapeutic agents such as "praziquantel", a recently developed anthelminthic for C. sinensis inftraction.

  • PDF

Cation exchange membrane and anion exchange membrane aided electrolysis processes for hypochlorite generation

  • Seong K. Kim;Dong-Min Shin;Ji Won Rhim
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.55-63
    • /
    • 2023
  • In this study, the influence of different IEMs (ion exchange membranes) to performance of the hypochlorite electrolysis unit with Cl2 recovery stream was investigated. More specifically, Nafion 117-a representative cation exchange membrane (CEM)-and aminated polypheylene oxide (APPO)-an anion exchange membrane (AEM)-were installed in the hypochlorite electrolysis unit, and the performance and the energy efficiency of the units were evaluated and compared. Regardless of whether CEM (Nafion 117) or AEM (APPO) was installed, the rate of hypochlorite generation was increased (by up to 24.3% and 22.2% for Nafion 117 and APPO, respectively) compared with the unit without an IEM. On the other hand, the power efficiency and the optimum operation condition of hypochlorite production units seem to depend on the conductivity and stability of the installed IEM. As the result, between Nafion 117 and APPO, higher performance and efficiency were achieved with Nafion 117, due to excellent conductivity and stability of the membrane.

Multi-objective optimization of stormwater pipe networks and on-line stormwater treatment devices in an ultra-urban setting

  • Kim, Jin Hwi;Lee, Dong Hoon;Kang, Joo-Hyon
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 2019
  • In a highly urbanized area, land availability is limited for the installation of space consuming stormwater systems for best management practices (BMPs), leading to the consideration of underground stormwater treatment devices connected to the stormwater pipe system. The configuration of a stormwater pipe network determines the hydrological and pollutant transport characteristics of the stormwater discharged through the pipe network, and thus should be an important design consideration for effective management of stormwater quantity and quality. This article presents a multi-objective optimization approach for designing a stormwater pipe network with on-line stormwater treatment devices to achieve an optimal trade-off between the total installation cost and the annual removal efficiency of total suspended solids (TSS). The Non-dominated Sorted Genetic Algorithm-II (NSGA-II) was adapted to solve the multi-objective optimization problem. The study site used to demonstrate the developed approach was a commercial area that has an existing pipe network with eight outfalls into an adjacent stream in Yongin City, South Korea. The stormwater management model (SWMM) was calibrated based on the data obtained from a subcatchment within the study area and was further used to simulate the flow rates and TSS discharge rates through a given pipe network for the entire study area. In the simulation, an underground stormwater treatment device was assumed to be installed at each outfall and sized proportional to the average flow rate at the outfall. The total installation cost for the pipes and underground devices was estimated based on empirical formulas using the flow rates and TSS discharge rates simulated by the SWMM. In the demonstration example, the installation cost could be reduced by up to 9% while the annual TSS removal efficiency could be increased by 4% compared to the original pipe network configuration. The annual TSS removal efficiency was relatively insensitive to the total installation cost in the Pareto-optimal solutions of the pipe network design. The results suggested that the installation cost of the pipes and stormwater treatment devices can be substantially reduced without significantly compromising the pollutant removal efficiency when the pipe network is optimally designed.

Analysis of the Phosphorus Contribution Rate by the Environment Fundamental Facilities Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 환경기초시설의 인 기여도 분석)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Yang, Heejeong;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1016-1027
    • /
    • 2010
  • The phosphorus contribution rate on water quality of North and South-Han River, and Gyungan-cheon by effluents from environmental fundamental facilities located in upstream basin of Paldang Lake were analyzed. QUALKO2 model was selected for the analysis of contrubution rate, and was constructed considering the location of the main point sources and all facilities in study area. The pollutant loading rates and arrival rates for each unit-watershed in study area were calculated for model operation. For the calibration and verification of model, 2006 water quality dataset from Ministry of Environment and the effluent loadings of the environmental fundamental facilities were used. Reliability Index (RI) method was used to estimate the validity of the results of calibration and verification. The phosphorous contribution rate(%) for each environmental fundamental facility were analyzed by excepting the effluent loading of the facility. The contribution rate was analyzed for each facility, facility groups separated by each main river and each unit-watershed. The main results of analysis for each facility are as follows; (i) the phosphorous contribution of B1 facility is 50%, which is the highest phosphorous contribution rate among those of nine facilities in the North-Han River Basin; (ii) the highest phosphorous contribution is 55.6% from J facility among eight facilities in the Gyungan Stream Basin; (iii) 40% from E treatment facility is the highest among those of twenty eight facilities in the South-Han River Basin.

Application of upflow multi-layer bioreactor (UMBR) for domestic wastewater treatment in HCMC

  • Cao, Duc Hung;Nguyen, Ngoc Han;Nguyen, Phuoc Dan;Bui, Xuan Thanh;Kwon, J.C.;Shin, H.S.;Lee, E.T.
    • Membrane and Water Treatment
    • /
    • v.3 no.2
    • /
    • pp.113-121
    • /
    • 2012
  • Up-flow multi-layer bioreactor (UMBR) is a hybrid system using dual sludge that consists of an up-flow multi-layer bioreactor as anaerobic/anoxic suspended growth microorganisms followed by an aeration tank. The UMBR acts as a primary settling tank, anaerobic/anoxic reactor, thickener which requires low energy due to mixing by up-flow stream. This study focused on using a pilot UMBR plant with capacity of 20-30 $m^3$/day for domestic wastewater in HCMC. HRTs of UMBR and aeration tank were 4.8 h and 7.2 h, respectively. The average MLSS of UMBR ranged from 10,000-13,600 mg/l SS. Internal recycle rate and sludge return were 200-300% and 150-200%, respectively. The results obtained from this study at flow rate of 20 $m^3$/day showed that removal of COD, SS, TKN, N-$NH_4$, T-N, and color were 91%, 87%, 86%, 80%, 91% and 91%, respectively.