• Title/Summary/Keyword: strain of tie section

Search Result 14, Processing Time 0.03 seconds

Applications of the ANFIS and LR in the prediction of strain in tie section of concrete deep beams

  • Mohammadhassani, Mohammad;Nezamabadi-pour, Hossein;Jameel, Mohammed;Garmasiri, Karim
    • Computers and Concrete
    • /
    • v.12 no.3
    • /
    • pp.243-259
    • /
    • 2013
  • Recent developments in Artificial Intelligence (AI) and computational intelligence have made it viable in the construction industry and structural analysis. This study usesthe Adaptive Network-based Fuzzy Inference System (ANFIS) as a modelling tool to predict the strain in tie section for High Strength Self Compacting Concrete (HSSCC) deep beams. 3773 experimental data were collected. The input data andits corresponding strains in tie section as output data were recorded at all loading stages. Results from ANFIS are compared with the classical linear regression (LR). The comparison shows that the ANFIS's results are highly accurate, precise and satisfactory.

Identification of a suitable ANN architecture in predicting strain in tie section of concrete deep beams

  • Mohammadhassani, Mohammad;Nezamabadi-pour, Hossein;Suhatril, Meldi;Shariati, Mahdi
    • Structural Engineering and Mechanics
    • /
    • v.46 no.6
    • /
    • pp.853-868
    • /
    • 2013
  • The comparison of the effectiveness of artificial neural network (ANN) and linear regression (LR) in the prediction of strain in tie section using experimental data from eight high-strength-self-compact-concrete (HSSCC) deep beams are presented here. Prior to the aforementioned, a suitable ANN architecture was identified. The format of the network architecture was ten input parameters, two hidden layers, and one output. The feed forward back propagation neural network of eleven and ten neurons in first and second TRAINLM training function was highly accurate and generated more precise tie strain diagrams compared to classical LR. The ANN's MSE values are 90 times smaller than the LR's. The correlation coefficient value from ANN is 0.9995 which is indicative of a high level of confidence.

Stress-Strain Relations of Plain and Confined Concrete (횡보강 효과를 고려한 콘크리트의 응력-변형도 관계)

  • 김진근;이태규;서용표
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.04a
    • /
    • pp.116-121
    • /
    • 1990
  • Baxed on the results tested by various researchers, a complete stress-strain relation of plain and confined concrete is proposed. The peak strength and the corresponding strain are calculated by using the Mohr-Coulomb theory and elastic tri-axial constitutive relation. A parametric study was conducted to assess the influence of the plain concrete strength, the degree of confinement, the shape of the section, and the tie configuration for the square section. According to this model, the behavior of concrete section is predicted, and compared with experimental data and other proposed models on circular and square sections. A good agreement between theoretical and experimental results is observed.

  • PDF

Determination of strut efficiency factor for concrete deep beams with and without fibre

  • Sandeep, M.S.;Nagarajan, Praveen;Shashikala, A.P.;Habeeb, Shehin A.
    • Advances in Computational Design
    • /
    • v.1 no.3
    • /
    • pp.253-264
    • /
    • 2016
  • Based on the variation of strain along the cross section, any region in a structural member can be classified into two regions namely, Bernoulli's region (B-region) and Disturbed region (D-region). Since the variation of strain along the cross section for a B-region is linear, well-developed theories are available for their analysis and design. On the other hand, the design of D-region is carried out based on thumb rules and past experience due to the presence of nonlinear strain distribution. Strut-and-Tie method is a novel approach that can be used for the analysis and design of both B-region as well as D-region with equal importance. The strut efficiency factor (${\beta}_s$) is needed for the design and analysis of concrete members using Strut and Tie method. In this paper, equations for finding ${\beta}_s$ for bottle shaped struts in concrete deep beams (a D-region) with and without steel fibres are developed. The effects of transverse reinforcement on ${\beta}_s$ are also considered. Numerical studies using commercially available finite element software along with limited amount of experimental studies were used to find ${\beta}_s$.

An Experimental Study on Stress-Strain Behavior of Confined Concrete Columns with Rectangular Sections (직사각형 단면 콘크리트 기둥의 응력-변형 거동에 관한 실험연구)

  • Oh, Byung-Hwan;Kim, Ki-Wan;Choi, Seung-Won;Park, Young-Ho
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.345-352
    • /
    • 2005
  • The purpose of this study is to analyze the stress-strain behavior of confined concrete columns with rectangular section. Uniaxial concentric loading tests of nineteen concrete columns with rectangular section ($150{\times}100$, $250{\times}100$, $350{\times}100\;mm$) were conducted. The main variables are transverse reinforcement volumetric ratio and spacing, cross tie arrangement, cross-section aspect ratio, and concrete strength. From the present experiments, it was found that the increase of transverse reinforcement ratio increases the maximum stress and ductility ratio and the reduction of the spacing of transverse reinforcement also increases the ductility and effective confinement. The increase of the aspect ratio of the cross-section does not influence much the stress-strain behavior of rectangular columns within the aspect ratio range of 3.5. The effect of concrete strength on ductility is also discussed.

  • PDF

Practical Application of Strut-and-tie model (스트럿-타이 모델의 실용화)

  • Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.979-984
    • /
    • 2008
  • This paper discusses how to use basic strut-and-tie models(STM) for practical application. Construction of STM starts with drawing of load paths with equilibrium conditions. Understanding of structural systems including form active systems, vector active systems, and section active systems help us select appropriate systems for possible STM. Simple circular fans can be employed for load paths from concentrated forces to distributed forces. Strength of struts depends on configuration of their nodal zones which meet tension ties and effective compressive strength. The effective compressive strength of struts are assumed to be mainly influenced by transverse strain.

  • PDF

Stress-Strain Behavior of Confined Concrete Columns according to Transverse Reinforcement Volumetric Ratio (횡방향 구속철근비에 따른 교각요소부재의 응력-변형 거동)

  • Oh Byung Hwan;Kim Ki Wan;Chioi Seung Won;Lee Jae Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.37-40
    • /
    • 2004
  • An experimental study was conducted to investigate the stress-strain behavior of confined concrete columns according to transverse reinforcement volumetric ratio. Uniaxial loading tests of eleven column specimens$(250\times100\times500mm)$ with rectangular section were conducted to study effect of confinement. The main variables in this test are transverse reinforcement volumetric ratio and cross tie arrangement. the results indicate that the strength and the ductility of confined concrete columns are subjected to transverse reinforcement volumetric ration and cross tie arrangement.

  • PDF

Behavior of continuous RC deep girders that support walls with long end shear spans

  • Lee, Han-Seon;Ko, Dong-Woo;Sun, Sung-Min
    • Structural Engineering and Mechanics
    • /
    • v.38 no.4
    • /
    • pp.385-403
    • /
    • 2011
  • Continuous deep girders which transmit the gravity load from the upper wall to the lower columns have frequently long end shear spans between the boundary of the upper wall and the face of the lower column. This paper presents the results of tests and analyses performed on three 1:2.5 scale specimens with long end shear spans, (the ratios of shear-span/total depth: 1.8 < a/h < 2.5): one designed by the conventional approach using the beam theory and two by the strut-and-tie approach. The conclusions are as follows: (1) the yielding strength of the continuous RC deep girders is controlled by the tensile yielding of the bottom longitudinal reinforcements, being much larger than the nominal strength predicted by using the section analysis of the girder section only or using the strut-and-tie model based on elastic-analysis stress distribution. (2) The ultimate strengths are 22% to 26% larger than the yielding strength. This additional strength derives from the strain hardening of yielded reinforcements and the shear resistance due to continuity with the adjacent span. (3) The pattern of shear force flow and failure mode in shear zone varies depending on the amount of vertical shear reinforcement. And (4) it is necessary to take into account the existence of the upper wall in the analysis and design of the deep continuous transfer girders that support the upper wall with a long end shear span.

Ductility enhancement of reinforced concrete thin walls

  • Kim, Jang Hoon
    • Computers and Concrete
    • /
    • v.2 no.2
    • /
    • pp.111-123
    • /
    • 2005
  • The ductility of reinforced concrete bearing walls subjected to high axial loading and moment can be enhanced by improving the deformability of the compression zone or by reducing the neutral axis depth. The current state-of-the-art procedure evaluating the confinement effect prompts a consideration of the spaces between the transverse and longitudinal reinforcing bars, and a provision of tie bars. At the same time, consideration must also be given to the thickness of the walls. However, such considerations indicate that the confinement effect cannot be expected with the current practice of detailing wall ends in Korea. As an alternative, a comprehensive method for dimensioning boundary elements is proposed so that the entire section of a boundary element can stay within the compression zone when the full flexural strength of the wall is developed. In this comprehensive method, the once predominant code approach for determining the compression zone has been advanced by considering the rectangular stress block parameters varying with the extreme compression fiber strain. Moreover, the size of boundary elements can also be determined in relation to the architectural requirement.

Shear strength and shear behaviour of H-beam and cruciform-shaped steel sections for concrete-encased composite columns

  • Keng-Ta Lin;Cheng-Cheng Chen
    • Steel and Composite Structures
    • /
    • v.47 no.3
    • /
    • pp.423-436
    • /
    • 2023
  • In this research, we tested 10 simply supported concrete-encased composite columns under monotonic eccentric loads and investigated their shear behaviour. The specimens tested were two reinforced concrete specimens, three steel-reinforced concrete (SRC) specimens with an H-shaped steel section (also called a beam section), and five SRC specimens with a cruciform-shaped steel section (also called a column section). The experimental variables included the transverse steel shape's depth and the longitudinal steel flange's width. Experimental observations indicated the following. (1) The ultimate load-carrying capacity was controlled by web compression failure, defined as a situation where the concrete within the diagonal strut's upper end was crushed. (2) The composite effect was strong before the crushing of the concrete outside the steel shape. (3) We adjusted the softened strut-and-tie SRC (SST-SRC) model to yield more accurate strength predictions than those obtained using the strength superposition method. (4) The MSST-SRC model can more reasonably predict shear strength at an initial concrete softening load point. The rationality of the MSST-SRC model was inferred by experimentally observing shear behaviour, including concrete crushing and the point of sharp variation in the shear strain.