• Title/Summary/Keyword: strain gauges

Search Result 366, Processing Time 0.032 seconds

A Study on Analysis of Ice Load Measured during the Voyage in the Arctic Sea (북극해 운항 중 계측된 빙하중에 대한 분석 연구)

  • Lee, Tak-Kee;Kim, Tae-Wook;Rim, Chae Whan;Kim, Heung-Sub
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.2
    • /
    • pp.107-113
    • /
    • 2014
  • The icebreaking research vessel, ARAON had her second ice trial in the Arctic Sea from 16th July to 12th August 2010. During the voyage, the local ice loads acting on the bow of port side were measured from 14 strain gauges. The measurements were also carried out in ice waters with various ice concentration ratio as well as the icebreaking performance tests. In this study, the ice loads measured during the 'general' operation in ice waters were analyzed. As a first step, the relationship between the location of strain gauges and the ice loads were investigated, and then the possibility for observation of higher ice loads was estimated based on the probability density function. The relationship between the ship speed and the ice load was also investigated. 718 peak stresses data higher than 20 MPa obtained from strain gauges array attached in longitudinally and vertically was analyzed. In general, the ice load increases as the ship speed increases in the low ship speed range, and ice load decreases as the ship speed is greater than a certain speed.

The Fabrication of a Micromachined Ceramic Thin-Film Pressure Sensor with High Overpressure Tolerance (과부하 방지용 마이크로머시닝 세라믹 박막형 압력센서의 제작)

  • Lim, Byoung-Kwon;Choi, Sung-Kyu;Lee, Jong-Chun;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.731-734
    • /
    • 2002
  • This paper describes on the fabrication and characteristics of a ceramic thin-film pressure sensor based on Ta-N strain gauges for harsh environment applications. The Ta-N thin-film strain gauges are sputter deposited onto a micromachined Si diaphragms with buried cavity for overpressure protectors. The proposed device takes advantages of the good mechanical properties of single crystalline Si as diaphragms fabricated by SDB and electrochemical etch-stop technology, and in order to extend the operating temperature range, it incorporates relatively the high resistance, stability and gauge factor of Ta-N thin-films. The fabricated pressure sensor presents a low temperature coefficient of resistance, high sensitivity, low non-linearity and excellent temperature stability. The sensitivity is $1.097{\sim}1.21mV/V{\cdot}kgf/cm^2$ in the temperature range of $25{\sim}200^{\circ}C$ and the maximum non-linearity is 0.43 %FS.

  • PDF

Fabrication of Micro Ceramic Thin-Film Type Pressure Sensors for High-Temperature Applications and Its Characteristics (고온용 마이크로 세라믹 박막형 압력센서의 제작과 그 특성)

  • Kim, Jae-Min;Lee, Jong-Choon;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.888-891
    • /
    • 2003
  • This paper describes on the fabrication and characteristics of micro ceramic thin-film type pressure sensors based on Ta-N strain-gauges for high-temperature applications. The Ta-N thin-film strain-gauges are deposited onto thermally oxidized Si diaphragms by RF sputtering in an argon-nitrogen atmosphere($N_2$ gas ratio: 8 %, annealing condition: $900^{\circ}C$, 1 hr.), Patterned on a wheatstone bridge configuration, and use as pressure sensing elements with a high stability and a high gauge factor. The sensitivity is $1.097{\sim}1.21mV/V.kgf/cm^2$ in the temperature range of $25{\sim}200^{\circ}C$ and the maximum non-linearity is 0.43 %FS. The fabricated pressure sensor presents a lower TCR, non-linearity than existing Si piezoresistive pressure sensors. The fabricated micro ceramic thin-film type pressure sensor is expected to be usefully applied as pressure and load sensors that is operable under high-temperature environments.

  • PDF

Field Investigation of Composite Behavior in High-speed Railway PSC Box Girder Bridge (고속전철 PSC 박스거더교 합성거동의 현장 계측에 관한 연구)

  • 김영진;김병석;강재윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.995-1000
    • /
    • 2000
  • Segmentally erected prestressed concrete box girder bridges have been widely used in Korean high speed railway. Segmental erection has been accomplished along the longitudinal direction and across the depth of cross section. The cross section is similar to a composite cross section, composed of old and new segments. Because these segments have different time-dependent creep and shrinkage properties, a stress redistribution takes place during the construction period. It is the main objective in this research to investigate this behavior. An actual bridge was instrumented with 96 vibrating wire embedded type strain gauges, 6 electronic type steel strain gauges, and 75 thermocouples. Two span continuous high speed railway bridge was selected. Two points of importance, such as the midpoint of the first span and the point of interior support, along the span of the girder were chosen to monitor the time dependent behaviors for an extended period of time. The data collection was starting just after concrete girder were cast and is still going on. According to the measured results, the strain distributions across the depth of the section at midspan and interior support were not continuous and the important redistribution of stresses takes place. Thus, rational design of prestressed concrete composite box girder bridges need.

Analytic Study on Dual Calibration Methods for Wind Blade Fatigue Tests Using Finite Element Models (유한요소모델을 활용한 풍력 블레이드의 피로 시험용 이축 캘리브레이션 기법 구축을 위한 해석적 연구)

  • Jinbong Kim;Si-Hyun Kim;Min-Gyu Kang;Woo-Kyoung Lee;Geunsu Joo
    • Journal of Wind Energy
    • /
    • v.13 no.3
    • /
    • pp.61-71
    • /
    • 2022
  • This paper presents a rational methodology to calculate the bending moment distribution for fatigue tests of wind blades using the pairs of the strain gauges attached on the surfaces of wind blades. The methodology is based on the equation for the strains as functions of their positions and bending stiffness under the pure bending of the asymmetric cross section of a beam. The equation is used to simultaneously calculate flapwise and edgewise bending moment distribution of the wind blade brought by single or even dual axis fatigue tests. The appropriate position and selection scheme of strain gauges on a blade section were proposed through the observation of the strains on blade surfaces simulated with the finite element analysis for the full 3D shell model of a 100m-length-grade wind blade. The blade bending moment distribution calculated from the strains using the proposed methodology has shown to have very small dependency on the gauge positions and selections of the gauge pairs.

Evaluation of Reliability of Strain Gauge Measurements for Geosynthetics (토목섬유 보강재에 적용한 스트레인게이지 실측값의 신뢰성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Li, Zhuang;Kim, Uk-Gie
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.87-96
    • /
    • 2015
  • Geosynthetics are widely used in different ways such as reinforcement of structures in road, railway, harbor and dam engineering, drainage, separation and erosion prevention. They are especially applied to reinforced retaining wall and slope or ground reinforcement. Recently, geosynthetics reinforced pile supported (GRPS) embankment was developed to improve stability and construability of embankments in railway engineering. Extension strains are usually measured by strain gauges adhered to geosynthetics to evaluate the stability of geosynthetics. However, the measurements are influenced by manufacturing method and stiffness of geosynthetics and also adherence of strain gauge. In this study, wide-width tensile strength tests were performed on three types of geosynthetics including geogrid, woven geotextile and non-woven geotextile. During the test, strains of geosynthetics were measured by both video extensometer and strain gauges adhered to the geosynthetics and the measured results were compared. Results show that the measured results by strain gauges have high reliability in case of large stiffness geosythetics like geogrid and woven geotextile, whereas they have very low reliability for small stiffness geosythetics like non-woven geotextile.

A Study on the Strain Analysis of Plane by Electronic Speckle Pattern Interferometry(ESPI) (전자처리스페클패턴간섭법에 의한 평판의 Strain 해석에 관한 연구)

  • Kim, Koung-Suk;Choi, Hyoung-Chul;Yang, Seung-Pil;Kim, Hyoung-Soo;Chung, Jae-Kang;Kim, Dong-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.101-111
    • /
    • 1994
  • Electronic speckle pattern interferometry(ESPI) using a CW laser, a video system and an image processor were applied to the in-plane displacement measurements. Unlike traditional strain gauges or Moire method, ESPI method requires no special surface preparation or attachments and it can be measured in-plane displacement without any contact and real time. In this experiment, specimen was loaded in paralled with a loa cell. The specimen was plance to which strain gauges was attached. The study provides an example of how ESPI have been used to measure displacement and strain distribution in this specimen. The results measured by ESPI were compared with the data which were measured by strain gauge method in tensile testing.

  • PDF

Strain Analysis in the Skin and Core Layers of Cross-Ply Composite Laminates Using A-EFPI Optical Fiber Sensor (광섬유 A-EFPI 센서를 이용한 직교적층 복합재료의 표피층 및 내부층의 변형률 해석)

  • 우성충;박래영;최낙삼;권일범
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.15-24
    • /
    • 2004
  • Longitudinal strains (${\varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic (GFRP) cross-ply composite laminates have been measured using the embedded optical fiber sensor of absolute extrinsic Fabry-Perot interferometer (A-EFPI). Transmission optical microscopy was used to investigate the damage behavior around the A-EFPI sensor. Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. It was shown that values of ${\varepsilon}_x$ in the interior of the skin layer and the core layer measured by embedded A-EFPI sensor were significantly higher than that of the specimen surface measured by strain gauges. The experimental results agreed well with those from finite element analysis on the basis of uniform stress model. Large strains in the core layer led to the occurrence of many transverse cracks which drastically reduced the strain at failure of optical fiber sensor embedded in the core layer.

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

A Study on the Single Side Strain Gauge Attatched Load Cell and Temperature Compensation (단일면에 스트레인게이지를 부착한 로드셀과 그 온도 보상에 관한 연구)

  • Park, Chan-Won;Choi, Gyu-Seok
    • Journal of Industrial Technology
    • /
    • v.13
    • /
    • pp.19-24
    • /
    • 1993
  • Compensation of temperature is very important to make high precision load cell. In this study, we developed a new type load cell. The structure of the load cell has four strain gauges on single side of the load cell beam. Also a new temperature compensation method was proposed and these characteristics were better than previous one. This study will offer application to other type of load cell and another sensors.

  • PDF