• Title/Summary/Keyword: strain effect

Search Result 4,538, Processing Time 0.046 seconds

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Autoradiographic Studies on the Inhibitory Effect of Dibutyryl Cyclic AMP on Mouse Oocyte Maturation in Vitro (Dibutyryl Cyclic AMP가 생쥐여포난자의 성숙에 미치는 억제효과에 관한 자기방사법적 연구)

  • Choi, Choon-Keun
    • Applied Microscopy
    • /
    • v.7 no.1
    • /
    • pp.21-43
    • /
    • 1977
  • This experiment was undertaken in order to localize the labeled dbcAMP (dibutyryl cyclic AMP) in oocytes whose development has been suppressed by cold dbcAMP for 6 or 19 hours in vitro. Mouse oocytes were obtained from the ovaries of 3-4 week old A strain female mice, by puncturing the Graafian follicles in the modified Krebs-Ringer bicarbonate salt solution under the dissecting microscope. Those oocytes which have intact germinal vesicle were cultured in the basic culture medium supplemented with 0.4% bovine serum albumin (BSA). Cultivation of the oocytes was carried out in a microtube developed by Cho (1974). The cultures were then incubated in a humidified 5% $CO_2$ incubator maintained at $37^{\circ}C$ for 6 or 19 hours (Donahue, 1968). DbcAMP was added to culture medium for a final concentration of 100ug/ml, and $^3H-dbc$ AMP (specific activity 13 Ci/mM) for a final concentration of $40{\mu}Ci/ml$ was also added to the medium. For electron microscopic autoradiography, those oocytes recovered from the culture were washed with phosphate buffer (pH 7.4), and immediately prefixed in a 2.5% glutaraldehyde overnight and postfixed for 2 hours at $4 ^{\circ}C$ in 1% osmium tetroxide in phosphate buffer with pH 7.4 (Palade, 1952). After fixation, the materials were dehydrated in graded alcohol series and embedded in Epon 812 mixture based on the standard procedures (Luft, 1961). The thin sections $600-700{\AA}$ thick were mounted on the grids of 200 meshes. The grids containing sections were coated with a nuclear emulsion Kodak NTB-3 and stored in a cold dark box (at $4^{\circ}C$) for 3 weeks. After exposure, the samples were developed with Kodak D-19 and stained with uranyl acetate and lead citrate. Routine observation was made with Hitachi HU-11E electron microsocope. The results of the observation were as followings: 1. It was found that the labeled dbcAMP penetrated the egg plasma membrane and dispersed at random in the cytoplasm. 2. It was also observed that most of the labeled dbcAMP was attached to microfibrillar lattices portion of the oocyte cytoplasm. There fore, it is presumed that the receptor of the dbcAMP is localized in the microfibrillar lattices of the oocyte. 3. It also seems that some other cell organells such as mitochondria, Golgi complex, cortical granules are not directly related to the action of the dbcAMP. 4. The labeled dbcAMP was neither observed in the membrane nor in the nucleus. Therefore, it seems that there is no relationship between the concentration of dbcAMP and the nuclear membranous permeability. 5. There was no difference in number of dbcAMP particles when oocytes were cultured for 6 hours and 19 hours. 6. However, it was observed that, in same of the oocytes suppressed in germinal vesicle by dbcAMP for 19 hours, cell organells were moved and concentrated to a small portion of the cytoplasm, and that the morphology of the organells greatly changed to an abnormal. form. Therefore, it is supposed that those oocytes were in the process of degeneration. From the above results, it is expected that dbcAMP penetrated the egg membrane and was bound to the receptor which seems to be located in the microfibrillar lattiees portion, and that this dbcAMP-receptor complex inhibited some enzyme system of the oocytes which are essential for the germinal vesicle breakdown.

  • PDF

Morphometric Study of the Irradiation Effect on the Cartilage Formation in the Rat Mandibular Condyle (방사선 조사가 백서 하악과두 연골 형성에 미치는 영향에 관한 형태계측학적 연구)

  • Kim Jeong-Hwa;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.87-103
    • /
    • 1999
  • Purpose: This study was undertaken to quantitatively estimate the degree of the damage and recovery of the irradiated rat condylar cartilage using the Image Analyzer. Materials and Methods: Experimental animals were 16 male rats of the Sprague-Dawley strain at the age of 20 day irradiated with the dose of 10 Gy in their head and neck region. Four rats were sacrificed at the each of the following time intervals - 1, 4, 7 and 14 days, respectively. The same number of control group animals were sacrificed at the each age of 21. 24, 27 and 34 days, respectively. The specimens were stained with 0.5% toluidine blue and examined with light microscope. The condylar cartilage was divided into 4 zones; fibrous zone, proliferating zone, upper hypertrophic zone, and lower hypertrophic zone. And then, the proliferating zone was subdivided into 2 layers - upper and lower layer, and upper and lower hypertrophic zone were subdivided into three layers, respectively - upper, middle and lower layer. With the aid of Image Analyzer, morphometric analysis was performed. The thickness, the numerical density of cells, the cell area density, the extracellular matrix area density, the mean area of single cell, the mean area of extracellular matrix per single cell were measured and analysed. Results: In the experimental group, the thickness of the fibrous zone was slightly increased and that of the proliferating zone and the upper and the lower hypertrophic zone was markedly decreased. With time, the thickness of the fibrous zone was gradually increased and that of the proliferating zone and the upper and the lower hypertrophic zone was steadily in the decreased state. The numerical density of cells of the proliferating zone was increased on post-irradiated 1 day, but decreased after post-irradiated 4 day, and that of the upper hypertrophic zone was decreased. The numerical density of cells of the lower hypertrophic zone was decreased in the early stage and then was decreased or not significantly different from that of the control group with time. In the experimental group, the cell area density of the fibrous zone and the proliferating zone was decreased in the early stage and then gradually increased or not significantly different from that of the control group with time. The cell area density of the upper and the lower hypertrophic zone was varied with time. The extracellular matrix area density value were totally opposite to the cell area density values: The mean area of single cell of the fibrous zone and the proliferating zone was .decreased on post-irradiated 1 day, and increased after post-irradiated 4 day. The mean area of single cell of the upper hypertrophic zone was varied with each layer and time. In the experimental group, the mean area of extracellular matrix per single cell of the fibrous zone was not significantly different with control group, and that of the proliferating zone was decreased on post-irradiated 1 day, and increased after post-irradiated 4 day. The mean area of extracellular matrix per single cell of the lower hypertrophic zone was increased in the early stage. and that of upper hypertrophic zone was varied with each layer and time. Conclusion: The condylar cartilages of rats were affected by irradiation, but the changes were vaned with each layer and time. By morphometric analysis. the changes of the cells of the condylar cartilage of irradiated rat could be calculated quantitatively.

  • PDF

EFFECT OF SOFT-START LIGHT CURING ON THE POLYMERIZATION AND THE CONTRACTION STRESS OF COMPOSITE RESIN (완속기시(Soft-start) 광조사 방식이 복합레진의 중합 및 수축응력에 미치는 효과)

  • Wee, You-Min;Oh, You-Hyang;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.332-343
    • /
    • 2005
  • The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at $400\;mw/cm^2$, plasma arc light curing for 6 seconds at $1300\;mW/cm^2$ and LED light curing for 10 seconds at $7The purpose of this study was to evaluate the influence of soft-start light curing on contraction stress and hardness of composite resin. Composite resin mold was cured using the one-step continuous curing method with three difference light sources; conventional halogen light curing for 40 seconds at . For the soft-start curing method ; 2 seconds light exposure at $650\;mW/cm^2$ followed by 3 seconds at $1300\;mW/cm^2$ and exponential increase with 5 seconds followed by 10 seconds at $700\;mW/cm^2$ were used. Contraction stress was measured using strain gauge method and Vickers hardness was measured 24 hours after polymerization at the top and bottom of specimens. Resin-acrylic interfaces were observed using a scanning electron microscope(SEM). The results of present study can be summarized as follows: 1. Contraction stresses at 10 min after polymerization were significantly reduced with the soft-start curing both in plasma and LED light sources(P<0.05). 2. Plasma light curing with soft-start resulted in not only the lowest contraction stress, but also the lowest hardness(P<0.05) 3. LED light curing with soft-start showed lower contraction stress than the one-step continuous halogen and LED light curing(P<0.05). 4. Microhardness of specimens cured by LED light with soft-start was equivalent to that of cured by the one-step continuous halogen and LED light(P>0.05). 5. Curing by LED light with soft-start and conventional halogen light resulted in better marginal sealing than plasma light and one-step LED light curing.

  • PDF

Finite Element Analysis of Bone Stress Caused by Horizontal Misfit of Implant Supported Three-Unit Fixed Prosthodontics (3차원 유한요소법에 의한 임플란트 지지 3본 고정성 가공 의치의 부적합도가 인접골 응력에 미치는 영향 분석)

  • Lee, Seung-Hwan;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.147-161
    • /
    • 2012
  • This study is to assess the effect of horizontal misfit of an implant supported 3-unit fixed prosthodontics on the stress development at the marginal cortical bone surrounding implant neck. Two finite element models consisting of a three unit fixed prosthodontics and an implant/bone complex were constructed on a three dimensional basis. The three unit fixed prosthodontics were designed either shorter (d=17.8mm model) or longer (d=18.0mm model) by 0.1mm than the span of two implants placed at the mandibular second premolar and second molar areas 17.9mm apart. Fitting of the fixed prosthodontics onto the implant abutments was simulated by a total of 6 steps, that is to say, 0.1mm displacement per each step, using DEFORM 3D (ver 6.1, SFTC, Columbus, OH, USA) program. Stresses in the fixed prosthodontics and implants were evaluated using von-Mises stress, maximum compressive stress, and radial stress as necessary. The d=17.8mm model assembled successfully on to the implant abutments while d=18.0mm model did not. Regardless if the fixed prosthodontics fitted onto the abutments or not, excessively higher stresses developed during the course of assembly trial and thereafter. On the marginal cortical bone around implants during the assembly, the peak tensile and compressive stresses were as high as 186.9MPa and 114.1MPa, respectively, even after the final sitting of the fixed prosthodontics (for d=17.8mm model). For this case, the area of marginal bone subject to compressive stresses above 55MPa, equivalent of the $4,000{\mu}{\varepsilon}$, i.e. the reported threshold strain to inhibit physiological remodeling of human cortical bone, extended up to 2mm away from implant during the assembly. Horizontal misfit of 0.1mm can produce excessively high stresses on the marginal cortical bone not only during the fixed prosthodontics assembly but also thereafter.

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Influence of Early- and Late-feathering Phenotype on Productive Performance in the Feather-sexing Strains of Korean Native Chicken (한국재래닭 깃털 성감별 계통에 있어 조우성과 만우성이 개체의 생산능력에 미치는 영향)

  • Sohn, Sea Hwan;Kim, Na Young;Park, Dhan Bee;Song, Hae Ran;Cho, Eun Jung;Choi, Seong Bok;Heo, Kang Nyeong;Choi, Hee Cheol
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.263-270
    • /
    • 2013
  • The vent sexing and the auto-sexing by using sex-linked traits are general sexing methods of day-old chicks. Currently, the feather sexing which is based on the differences in the feather characteristics at hatching is the representative sexing method of chicken, because the late-feathering is sex-linked trait. The feather sexing can be used if the breed has dominant feathering gene (K) in maternal and recessive gene ($k^+$) in paternal. Therefore it is necessary to identify the association of feathering genes and quantitative traits in chickens. In this study, we investigated the influence of the rate of feathering on productive traits in Korean Native Chicken. In results, there was no significant difference between early-feathering chickens and late-feathering chickens in reproductive performance such as fertility and hatchability. Livability, body weights, egg production, egg weight and egg quality also did not significantly differ between early- and late-feathering chickens. Age at first egg was the only trait of those tested in which significant difference was observed. The early-feathering chickens laid eggs 3 days earlier than late-feathering chicken. As a result, there is no influence of feathering phenotypes on productive performance in Korean Native Chickens. Consequentially, establishing the feather sexing strain is available using the Korean Native Chicken breed without considering of the effect of feathering genes on productive traits.

Experimental Studies on the Properties of Epoxy Resin Mortars (에폭시 수지 모르터의 특성에 관한 실험적 연구)

  • 연규석;강신업
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.1
    • /
    • pp.52-72
    • /
    • 1984
  • This study was performed to obtain the basic data which can be applied to the use of epoxy resin mortars. The data was based on the properties of epoxy resin mortars depending upon various mixing ratios to compare those of cement mortar. The resin which was used at this experiment was Epi-Bis type epoxy resin which is extensively being used as concrete structures. In the case of epoxy resin mortar, mixing ratios of resin to fine aggregate were 1: 2, 1: 4, 1: 6, 1: 8, 1:10, 1 :12 and 1:14, but the ratio of cement to fine aggregate in cement mortar was 1 : 2.5. The results obtained are summarized as follows; 1.When the mixing ratio was 1: 6, the highest density was 2.01 g/cm$^3$, being lower than 2.13 g/cm$^3$ of that of cement mortar. 2.According to the water absorption and water permeability test, the watertightness was shown very high at the mixing ratios of 1: 2, 1: 4 and 1: 6. But then the mixing ratio was less than 1 : 6, the watertightness considerably decreased. By this result, it was regarded that optimum mixing ratio of epoxy resin mortar for watertight structures should be richer mixing ratio than 1: 6. 3.The hardening shrinkage was large as the mixing ratio became leaner, but the values were remarkably small as compared with cement mortar. And the influence of dryness and moisture was exerted little at richer mixing ratio than 1: 6, but its effect was obvious at the lean mixing ratio, 1: 8, 1:10,1:12 and 1:14. It was confirmed that the optimum mixing ratio for concrete structures which would be influenced by the repeated dryness and moisture should be rich mixing ratio higher than 1: 6. 4.The compressive, bending and splitting tensile strenghs were observed very high, even the value at the mixing ratio of 1:14 was higher than that of cement mortar. It showed that epoxy resin mortar especially was to have high strength in bending and splitting tensile strength. Also, the initial strength within 24 hours gave rise to high value. Thus it was clear that epoxy resin was rapid hardening material. The multiple regression equations of strength were computed depending on a function of mixing ratios and curing times. 5.The elastic moduli derived from the compressive stress-strain curve were slightly smaller than the value of cement mortar, and the toughness of epoxy resin mortar was larger than that of cement mortar. 6.The impact resistance was strong compared with cement mortar at all mixing ratios. Especially, bending impact strength by the square pillar specimens was higher than the impact resistance of flat specimens or cylinderic specimens. 7.The Brinell hardness was relatively larger than that of cement mortar, but it gradually decreased with the decline of mixing ratio, and Brinell hardness at mixing ratio of 1 :14 was much the same as cement mortar. 8.The abrasion rate of epoxy resin mortar at all mixing ratio, when Losangeles abation testing machine revolved 500 times, was very low. Even mixing ratio of 1 :14 was no more than 31.41%, which was less than critical abrasion rate 40% of coarse aggregate for cement concrete. Consequently, the abrasion rate of epoxy resin mortar was superior to cement mortar, and the relation between abrasion rate and Brinell hardness was highly significant as exponential curve. 9.The highest bond strength of epoxy resin mortar was 12.9 kg/cm$^2$ at the mixing ratio of 1:2. The failure of bonded flat steel specimens occurred on the part of epoxy resin mortar at the mixing ratio of 1: 2 and 1: 4, and that of bonded cement concrete specimens was fond on the part of combained concrete at the mixing ratio of 1 : 2 ,1: 4 and 1: 6. It was confirmed that the optimum mixing ratio for bonding of steel plate, and of cement concrete should be rich mixing ratio above 1 : 4 and 1 : 6 respectively. 10.The variations of color tone by heating began to take place at about 60˚C, and the ultimate change occurred at 120˚C. The compressive, bending and splitting tensile strengths increased with rising temperature up to 80˚ C, but these rapidly decreased when temperature was above 800 C. Accordingly, it was evident that the resistance temperature of epoxy resin mortar was about 80˚C which was generally considered lower than that of the other concrete materials. But it is likely that there is no problem in epoxy resin mortar when used for unnecessary materials of high temperature resistance. The multiple regression equations of strength were computed depending on a function of mixing ratios and heating temperatures. 11.The susceptibility to chemical attack of cement mortar was easily affected by inorganic and organic acid. and that of epoxy resin mortar with mixing ratio of 1: 4 was of great resistance. On the other hand, when mixing ratio was lower than 1 : 8 epoxy resin mortar had very poor resistance, especially being poor resistant to organicacid. Therefore, for the structures requiring chemical resistance optimum mixing of epoxy resin mortar should be rich mixing ratio higher than 1: 4.

  • PDF

Optimization of Culture Conditions for D-Tagatose Production from D-Galactose by Enterobacter agglomerans. (Entrobacter agglomerans에 의한 D-Galactose로부터 D-Tagatose 생산조건의 최적화)

  • 오덕근;노회진;김상용;노봉수
    • Microbiology and Biotechnology Letters
    • /
    • v.26 no.3
    • /
    • pp.250-256
    • /
    • 1998
  • D-Tagatose production from D-galactose was investigated using 35 type strains of American Culture Type Collection (ATCC) and Korean Collection for Type Cultures (KCTC) which have potential to produce D-tagatose. Enterobacter agglomerans ATCC 27987 was selected as a D-tagatose producing strain due to its short fermentation time and high production of D-tagatose. Optimization of the culture conditions for D-tagatose production by E. agglomerans ATCC 27987 was performed. Among various carbon sources, D-galactose was the most effective carbon source for D-tagatose production. As the D-galactose concentration was increased, cell growth and D-tagatose production increased. Effect of nitrogen sources on D-tagatose production was studied. Of inorganic nitrogen sources, ammonium sulfate was effective one for D-tagatose production and yeast extract was the most suitable organic nitrogen nutrient. The concentrations of inorganic compounds such as KH$_2$PO$_4$, K$_2$HPO$_4$, and MgSO$_4$$.$7H$_2$O were also optimized for D-tagatose production. The optimal medium was determined to contain D-galactose of 20 g/l, yeast extract of 5.0 g/l, (NH$_4$)$_2$SO$_4$ of 2.0 g/l, KH$_2$PO$_4$ of 5.0 g/l, K$_2$HPO of 5.0 g/l, and MgSO$_4$$.$7H$_2$O of 5 mg/l. The optimal environmental conditions in a 250-$m\ell$ flask were found to be pH of 6.0, temperature of 30$^{\circ}C$, and agitation speed of 150 rpm. D-tagatose of 0.41 g/l could be obtained in 24 h from 20 g/l D-galactose at the optimal culture condition without induction and cell concentration.

  • PDF

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.