• 제목/요약/키워드: storing temperature

검색결과 229건 처리시간 0.023초

Low-temperature Synthesis of Graphene-CdLa2S4 Nanocomposite as Efficient Visible-light-active Photocatalysts

  • Zhu, Lei;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제52권3호
    • /
    • pp.173-179
    • /
    • 2015
  • We report the facile synthesis of graphene-$CdLa_2S_4$ composite through a facile solvothermal method at low temperature. The as-prepared products were characterized by X-ray diffraction (XRD) and by Scanning electron microscopy (SEM) with energy dispersive X-ray (EDX) analysis and BET analysis, revealing the uniform covering of the graphene nanosheet with $CdLa_2S_4$ nanocrystals. The as-prepared samples show a higher efficiency for the photocatalytic degradation of typical MB dye compared with P25 and $CdLa_2S_4$ bulk nanoparticles. The enhancement of visible-light-responsive photocatalytic properties by decolorization of Rh.B dye may be attributed to the following causes. Firstly, graphene nanosheet is capable of accepting, transporting and storing electrons, and thus retarding or hindering the recombination of the electrons with the holes remaining on the excited $CdLa_2S_4$ nanoparticles. Secondly, graphene nanosheet can increase the adsorption of pollutants. The final cause is that their extended light absorption range. This work not only offers a simple way to synthesize graphene-based composites via a one-step process at low temperature but also a path to obtain efficient functional materials for environmental purification and other applications.

상태방정식을 이용한 고압수소 저장을 위한 수소 열역학 물성 계산 및 비교 (Calculation and Comparison of Thermodynamic Properties of Hydrogen Using Equations of State for Compressed Hydrogen Storage)

  • 박병흥
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.184-193
    • /
    • 2020
  • One of the technical methods to increase the volumetric energy density of hydrogen is to pressurize the gaseous hydrogen and then contain it in a rigid vessel. Especially for automotive systems, the compressed hydrogen storage can be found in cars as well as at refueling stations. During the charging the pressurized hydrogen into a vessel, the temperature increases with the amount of stored hydrogen in the vessel. The temperature of the vessel should be controlled to be less than a limitation for ensure stability of material. Therefore, the accurate estimation of temperature is of significance for safely storing the hydrogen. In this work, three well-known cubic equations of state (EOSs) were adopted to examine the accuracy in regenerating thermodynamic properties of hydrogen within the temperature and pressure ranges for the compressed hydrogen storage. The formulations representing molar volume, internal energy, enthalpy, and entropy were derived for Redlich-Kwong (RK), Soave-Redlioch-Kwong (SRK), and Peng-Robinson (PR) EOSs. The calculated results using the EOSs were compared with literature data given by NIST. It was revealed that the accuracies of RK and SRK EOSs were satisfactorily compatible and better than the results by PR EOS.

냉이온수기 냉각시스템에 관한 열유동 해석 (Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus)

  • 전성오;이상준;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

숙도 및 저장온도가 생대추의 저장적성에 미치는 영향 (Effect of Maturity and Storage Temperature on Preservation of Fresh Jujube)

  • 안덕순;이동선
    • 한국식품과학회지
    • /
    • 제29권4호
    • /
    • pp.758-763
    • /
    • 1997
  • 당도와 ascorbic acid함량이 높은 우수한 신선 과일인 생대추를 장기간 저장하기 위하여 숙도 및 저장온도에 따른 무등품종 대추의 호흡특성, 저장 중 품질변화를 측정하였다. 녹숙 대추와 적숙 대추의 숙도에 따라서 호흡속도는 차이가 없어서 non-climacteric특성으로 간주될 수 있었고, 호흡의 온도의존성에서도 숙도간에 차이가 없었다. 적숙 대추가 녹숙 대추에 비해서 단위과중이 약간 크며, 가용성 고형분 농도와 ascorbic acid 함량이 약간 높았다. 대추는 저장 중 조직의 연화가 먼저 나타난 후 부패가 진행되었다. 대추의 저장 중 연화 및 부패의 진행은 녹숙대추의 경우가 적숙대추에 비해서 늦어서 장기저장을 위해서는 녹숙대추를 저장하는 것이 유리하였다. 저장 중 녹숙 대추의 표면색택은 붉은 색으로 착색이 진행되고 가용성 고형분은 증가하고, 총산과 ascorbic acid 함량은 감소하였다. $-2^{\circ}C,\;0^{\circ}C,\;5^{\circ}C,\;10^{\circ}C,\;20^{\circ}C$에서의 녹숙 대추의 저장실험에서는 $-2^{\circ}C$에서는 저온장해가 발생하였고, $5^{\circ}C$ 이상의 온도에서는 온도가 높을수록 품질변화와 부패가 빨라서, $0^{\circ}C$가 저장적온으로 판단되었다. 저장적온인 $0^{\circ}C$에서 대추는 40일정도 밖에 신선한 상태로 저장될 수 없어서 보다 장기간의 저장이 가능한 포장 기법의 적용이 필요한 것으로 평가되었다.

  • PDF

LNG선박용 내조시스템 소재의 기계적 특성 및 피로강도 평가 (Evaluation of the Fatigue Strength and the Mechanical Properties for Cargo Containment System in LNG Ship)

  • 심희진;김민태;윤인수;김영균;김정규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1-6
    • /
    • 2007
  • The membrane type LNG(Liquefied Natural Gas) cargo containment system is a special design structure for the large deformation behavior at LNG temperature$(-162^{\circ}C)$. The design of membrane is required great confidence so that membrane can plat role in the tightness of flammable fluid storing. LNG cargo containment is loaded and unloaded LNG between twice and five times in a week. During this process, the membrane has large deformation behavior due to the variation of temperature and pressure to the self weight. In this study, the evaluation of the fatigue strength of membrane is very important to determine the design life of LNG storage tank and to evaluate the mechanical properties at the LNG temperature. Also, in the view point of large deformation, the evaluation method is applied conservatively $\epsilon-N_f$ curve of SUS 304L.

  • PDF

A15083-O GMAW 용접시 불활성가스 혼합비가 용접부의 인성에 미치는 영향에 관한 연구 (The Influence of Shield Gas Ratio on the Toughness of A15083-0 GMAW Weld Zone)

  • 이동길;김건호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.113-199
    • /
    • 2002
  • In this study, the toughness was evaluated by using the instrumented Charpy impact testing procedures for A15083-O aluminum alloy used in the LNG carrying and storing tank. The specimens were GMAW welded with four different mixing shield gas ratios (Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%), and tested at four different temperatures(+25, -30, -85, and -196$^{\circ}C$ ) in order to investigate the influence of the mixing shield gas ratio and the low temperature. The specimens were divided into base metal, weld metal, fusion line, and HAZ specimen according to the worked notch position. From experiment, the maximum load increased a little up to -85$^{\circ}C$, and the maximum load and maximum displacement were shown the highest and the lowest at -196$^{\circ}C$ than the other test temperatures. The absorption energy of weld metal notched specimens was not nearly depends on test temperature and mixing shield gas ratio because the casting structure was formed in weld metal zone. In the other hand, the others specimens was shown that the lower temperature, the higher absorption energy slightly up to -85$^{\circ}C$ but the energy was decreased so mush at -196$^{\circ}C$

  • PDF

Ni Nanoparticles-hollow Carbon Spheres Hybrids for Their Enhanced Room Temperature Hydrogen Storage Performance

  • Kim, Jin-Ho;Han, Kyu-Sung
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.550-557
    • /
    • 2013
  • A glucose hydrothermal method is described for preparing hollow carbon spheres (HCS), which have a regular morphology and a high Brunauer-Emmett-Teller surface area of 28.6 m2/g. Scanning electron microscopy shows that they have thin shells and diameter between 2 and 8 ${\mu}m$. The HCSs were modified for the enhanced room temperature hydrogen storage by employing Ni nanoparticles on their surface. The Ni-decorated HCSs were characterized by X-ray diffraction, transmission electron microscopy coupled with an energy dispersive spectroscope, and an inductively coupled plasma spectrometer, indicating that fine and well-distributed Ni nanoparticles can be accomplished on the HCSs. The hydrogen uptake capacity in HCSs with and without Ni loading was evaluated using a high-pressure microbalance at room temperature under a hydrogen pressure upto 9 MPa. As much as 1.23wt.% of hydrogen can be stored when uniformly distributed Ni nanoparticles are formed on the HCSs, while the hydrogen uptake capacity of as-received HCSs was 0.41 wt.%. For Ni nanoparticle-loaded HCSs, hydrogen molecules could be easily dissociated into atomic hydrogen and then chemically adsorbed by the sorbents, leading to an enhanced capacity for storing hydrogen.

농용(農用) 내연기관(內燃機關) 폐열(廢熱)의 열(熱)에너지 회수(回收)(II) -시스템 Simulation과 안정성(安定性) 실험(實驗)- (Thermal Energy Recovery from Waste Heat of an I.C. Engine for Agriculture(II) -System Simulation and Stability Test-)

  • 서상룡;유수남
    • Journal of Biosystems Engineering
    • /
    • 제12권1호
    • /
    • pp.6-13
    • /
    • 1987
  • A mathematical model for the waste heat recovery system for an engine was developed. The model based on the experimental data reported before was validated and was used to predict the waste heat recovery and recoverable heat of the engine at various operating conditions of the engine and the system. The model was also used to determine flow rates of the circulating water in the system for a certain temperature increment of the water at various operating conditions of the engine to give basic data to design the system. Stability of the system performance was tested on subjects of vapor lock problem, thermal characteristics of the thermostatic valve, and temperature variation of the circulating water in the engine and fuel consumption of the engine during each mode of the system operation and its change into the other. The test showed that the system operation was stable enough. Temperature profile in the thermal energy storage (TES) was observed during storing thermal energy, and thermal stratification in the TES was well formed acceptable to be used in the system. Finally a scheme to automatize the system was suggested.

  • PDF

도축부산물인 돈혈의 재활용에 관한 연구 (Utilization of Slaughter Porcine Blood as an Animal Feed)

  • 김정학;박강희;류경선;이제훈
    • 한국축산시설환경학회지
    • /
    • 제3권2호
    • /
    • pp.133-143
    • /
    • 1997
  • Optimal conditions for collecting, storing and drying temperature to utilize slaughter porcine blood for blood meals and the effects of blood meal on growth in broiler chicks were investigated. Dry matter and protein contents of slaughter procine blood were 19.5% and 77%(dry basis), respectively. As for the composites of amino acids in the blood, aspartic acid, arginine, glycine, histidine, leucine, lysine, phenylalanin threonine were shown high. There was no significant difference between the collections by bloodletting and vacuumming in terms of microbial contamination. Storage of slaughter porcine blood showed no differences in protein, DNA and triglyceride contents and pH between the storage methods of freezing (-20$^{\circ}C$) and refrigerating (-4$^{\circ}C$). In case of room temperature storage, however, the decrease in pH and the appearance of new protein due to microbial contaminations increased as the storage periods were prolonged. When drying was done by flash methods, the drying period got shortened as the temperature became higher, yet protein and triglyceride were destoryed more. When drying was done over 120$^{\circ}C$, even at the same degree, the breakdowns of protein and triglyceride increased more as drying period got longer. In feeding trials of broiler chicks, dietary supplementation of the flash dried blood meal at 2% level showed significant difference in growth rate(P<.05%). These results indicated that the appropriate handling and manufacturing of slaughter porcine blood enabled the blood to be used as a protein source for broiler chicks.

Al5083-O GMA 용접시 불활성가스 혼합비가 용접부의 인성에 미치는 영향에 관한 연구 (The Influence of Shield Gas Ratio on the Toughness of Al5083-O GMA Welding Zone)

  • 이동길;조상곤;김건호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권6호
    • /
    • pp.653-660
    • /
    • 2002
  • In this study, the toughness was evaluated by using the instrumented Charpy impact testing procedures for A15083-O aluminum alloy used in the LNG carrying and storing tank. The specimens were GMAW welded with four different mixing shield gas ratios (Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%), and tested at four different temperatures(+25, -30, -85, and $-196^{\circ}C$) in order to investigate the influence of the mixing shield gas ratio and the low temperature. The specimens were divided into base metal, weld metal, fusion line, and HAZ specimen according to the worked notch position. From experiment, the maximum load increased a little up to -$85^{\circ}C$ , and the maximum load and maximum displacement were shown the highest and the lowest at -$196^{\circ}C$ than the other test temperatures. The absorption energy of weld metal notched specimens was not nearly depends on test temperature and mixing shield gas ratio because the casting structure was formed in weld metal zone. In the other hand, the other specimens were shown that the lower temperature, the higher absorption energy slightly up to $-85^{\circ}C$ but the energy was decreased so mush at $-196^{\circ}C$.