• Title/Summary/Keyword: storage reliability

Search Result 573, Processing Time 0.024 seconds

Supervisor System Development for Improving Quality of RFID Cold Storage Management Systems (RFID 냉동창고 관리시스템의 품질향상을 위한 슈퍼바이저 시스템 개발)

  • Moon, Mi-Kyeong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.109-117
    • /
    • 2014
  • A cold storage is a warehouse of a insulated building with cooling installations. It has many different types of cold rooms with temperatures below 0 degrees Celsius, and the sequential workflow such as receiving, picking and packing runs in that rooms. Recently, the cold storages have adopted RFID technology, and consequently, warehouse product management in them are becoming intelligent and network. However, information inconsistency in warehouses caused by physical and logical errors reduces reliability in the RFID cold storage management system and worsens their work efficiency. Therefore, it is necessary to develop an early detection system to identify errors. In this paper, we suggest a supervisory system detecting logical errors on business processes of the RFID cold storage. It is composed of a master supervisor and mobile supervisor. In the master supervisor, the manager can set the constraints conditions and get alerts, and in the mobile supervisor, the workers confirm and deal with these faults directly. The supervisory system improve reliability of the RFID cold storage management system by recognizing a failure to identify physically and logically using these constraint conditions. This paper shows that the supervisory system can reduce the average recovery time to improve reliability by decreasing the time for detecting and analyzing errors in the RFID cold storage management system.

Simulation of Stage-Storage Curve Function in Irrigation Reservoirs (저수지 내용적 곡선의 모의발생)

  • 김현영;윤인택;최용선;오수훈
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.5
    • /
    • pp.73-80
    • /
    • 1995
  • The uses of stage-storage curve function are diverse in irrigation reservoirs. The curve functions would be used to determine the optimal size of spillway length and the inundation area above full water level based on the flood routing in reservoirs. In addition, the curve function would he used to transform the stage to the storage for the reservoir water management, in which the storage is the supply water. Besides those, the curve is necessary for the planning of dredging, the estimation of the effective and the dead storage, the drought management by reservoir, etc. The curve function data, however, are almost unavailable for these purposes. According to the statistics, about 74% of the 2, 900 resevoirs which are maintained by Farm Land Improvement Association have no more effective data. Therefore, the simulation of the curve function could be better alternative. The curve functions were simulated derivating the regression equations based on the basin relief ratio and the effective depth. The results of the verification show the enough reliability of the application to generate the curve function in some reservoirs which do not have the surveyed stage-storage data. Also, even though the averaged curve function would be applicated without the basin relief ratio data, the result shows that the simulated curve is closer to the real one than the linear function by only the existing effective storage data.

  • PDF

Implementation of a Residual Quantity Monitoring System in a Liquefied Gas Storage Tank based on Wireless Sensor Network Technology (무선센서 네트워크 기술 기반 액화가스 저장탱크 내 잔량 모니터링 시스템 구현)

  • Kim, Min-Kyu;Han, Hae-Jin;Han, Jaehwan
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.352-356
    • /
    • 2018
  • This paper relates to a technology for monitoring a liquefied gas storage tank in the special gas field where demand is increasing owing to the continuous growth of related fields such as the semiconductor, display, and ICT convergence electronics industries. We have proposed a system for real - time monitoring using wireless sensor network technology, and implemented a system consisting of a sensor unit, transmitter module, and receiver module to be attached to a liquefied gas storage tank. The system was applied to LCO2 tanks among various liquefied gas storage tanks to verify the feasibility. The storage tanks employed in the experiments has capacities of 16,179 l and was 1,920 mm in inner diameter. Furthermore, the density was 1.03 g/l. The measured data were compared with reference data on the remaining gas level versus the $CO_2$ height of the surface, expressed using a conventional water meter, provided by an existing storage tank supplier. The experimental results show that the data is similar to the standard data provided by the tank supplier, and has a high accuracy and reliability within an error range of 0.03%.

Storage lifetime estimation of detonator in Fuse MTSQ KM577A1 (기계식 시한 신관 KM577A1용 기폭관 저장수명 예측)

  • Chang, Il-Ho;Park, Byung-Chan;Hwang, Taek-Sung;Hong, Suk-Whan;Back, Seung-Jun;Son, Young-Kap
    • Journal of Korean Society for Quality Management
    • /
    • v.38 no.4
    • /
    • pp.504-511
    • /
    • 2010
  • A fuze detonator comprising star shells is an important device so that its failure usually leads to failure of the shells. In this paper, accelerated degradation tests of RD1333 (lead azide) using temperature stress were performed, and then degradation data of explosive power for the detonator were analyzed to predict the storage lifetime of detonator. Degradation data analysis to estimate the storage lifetime is based on a distribution-based degradation process. Statistical distribution parameters of explosive power degradation measures at each time were estimated for each temperature level, and then reliability of the detonator for each accelerated temperature level was estimated using both time-varying distribution parameters and critical level of explosive power. Arrhenius model was applied to estimate storage lifetime of the detonator under the field temperature condition. Accelerated distribution-based degradation analysis to estimate storage lifetime is explained in detail, and estimation results are compared to field data of storage lifetime in this paper.

Development of an Advanced Hybrid Energy Storage System for Hybrid Electric Vehicles

  • Lee, Baek-Haeng;Shin, Dong-Hyun;Song, Hyun-Sik;Heo, Hoon;Kim, Hee-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • Hybrid Electric Vehicles (HEVs) utilize electric power as well as a mechanical engine for propulsion; therefore the performance of HEV s can be directly influenced by the characteristics of the Energy Storage System (ESS). The ESS for HEVs generally requires high power performance, long cycle life and reliability, as well as cost effectiveness. So the Hybrid Energy Storage System (HESS), which combines different kinds of storage devices, has been considered to fulfill both performance and cost requirements. To improve operating efficiency, cycle life, and cold cranking of the HESS, an advanced dynamic control regime with which pertinent storage devices in the HESS can be selectively operated based on their status was presented. Verification tests were performed to confirm the degree of improvement in energy efficiency. In this paper, an advanced HESS with improved an Battery Management System (BMS), which has optimal switching control function based on the estimated State of Charge (SOC), has been developed and verified.

Reliability Characteristics of a Package-on-Package with Temperature/Humidity Test, Temperature Cycling Test, and High Temperature Storage Test (온도/습도 시험, 온도 싸이클링 시험 및 고온유지 시험에 따른 Package-on-Package의 신뢰성)

  • Park, Donghyun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.43-49
    • /
    • 2016
  • Reliability characteristics of thin package-on-packages were evaluated using T/H (temperature/humidity) test at $85^{\circ}C/85%$ for 500 hours, TC (temperature cycling) test at $-40{\sim}100^{\circ}C$ for 1,000 cycles, and HTS (high temperature storage) test at $155^{\circ}C$ for 1,000 hours. The average resistance of the solder-bump circuitry between the top and bottom packages of 24 package-on-package (PoP) samples, which were processed using polyimide thermal tape, was $0.56{\pm}0.05{\Omega}$ and quite similar for all 24 samples. Open failure of solder joints did not occur after T/H test for 500 hours, TC test for 1,000 cycles, and HTS test for 1,000 hours, respectively.

Storage Manager for Data Broadcast (데이터 방송을 위한 스토리지 매니저)

  • Ko, Sang-Won;Jeon, Je-Min;Won, Jae-Hoon;Kim, Seh-Chang;Kim, Jun-Sun
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.639-642
    • /
    • 2008
  • In this paper, we present the storage manager for digital broadcast environment. Data stream in real-time broadcast environment flows into set-top box continuously but, Given the file-system doesn't consider such characteristics. The storage manager provides reliability and flexibility for digital broadcast in set-top box.

  • PDF

Improvement of delayed hydride cracking assessment of PWR spent fuel during dry storage

  • Hong, Jong-Dae;Yang, Yong-Sik;Kook, Donghak
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.614-620
    • /
    • 2020
  • In a previous study, delayed hydride cracking (DHC) assessment of pressurized water reactor (PWR) spent fuel during dry storage using the threshold stress intensity factor (KIH) was performed. However, there were a few limitations in the analysis of the cladding properties, such as oxide thickness and mechanical properties. In this study, those models were modified to include test data for irradiated materials, and the cladding creep model was introduced to improve the reliability of the DHC assessment. In this study, DHC susceptibility of PWR spent fuel during dry storage depending on the axial elevation was evaluated with the improved assessment methodology. In addition, the sensitivity of affecting parameters such as fuel burnup, hydride thickness, and crack aspect ratio are presented.

Using a Disturbance Observer for Eccentricity Compensation in Optical Storage Systems

  • Kim, Kyung-Soo
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.319-323
    • /
    • 2002
  • In this paper, we consider the track-following control problem in the optical data storage systems in the presence of the eccentricity. The eccentricity results in the radial deviation of the objective lens so that it degrades the reliability of the data decoding system. To cope with the eccentricity, an adaptive disturbance compensation technique is newly proposed in the time domain based on a disturbance observer of reduced order, which effectively estimates the low frequency components of the disturbance. The proposed compensator is simply added to the conventional feedback control. The error dynamics of the observer and the sensitivity analysis are given to illustrate the effectiveness of the proposed approach. Finally, through experiments in an optical storage system, the feasibility of the proposed approach is verified.