  • With increasing demand for LNG as energy resources and need for $CO_2$ sequestration as greenhouse gas, more storage facilities are required in Korea. Due to the recent acute safety concerns and land shortage, storage facilities tend to be located underground. In design and construction of underground storage for low and high temperature materials, besides their mechanical characteristics, the thermal characteristics of rock under temperature variation should be understood. In this study, laboratory experiments for the measurement of the thermal expansion coefficient of rock were performed using strain gauge in consideration of the particle size of mineral and experiment temperature range. Experiment results show that thermal expansion coefficient decreased as the temperature decreases. In addition, linear thermal expansion coefficient was developed for typical Korean rocks such as granite. The results of this study can be utilized for the evaluation of thermal propagation in rock mass and the thermo-mechanical stability of underground facilities.

A New Approach in Numerical Assessment of the Cavitation Behaviour of Centrifugal Pumps

  • Stuparu, Adrian;Susan-Resiga, Romeo;Anton, Liviu Eugen;Muntean, Sebastian
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.104-113
    • /
    • 2011
  • The paper presents a new method for the analysis of the cavitation behaviour of hydraulic turbomachines. This new method allows determining the coefficient of the cavitation inception and the cavitation sensitivity of the turbomachines. We apply this method to study the cavitation behaviour of a large storage pump. By plotting in semi-logarithmic coordinates the vapour volume versus the cavitation coefficient, we show that all numerical data collapse in an exponential manner. By analysis of the slope of the curve describing the evolution of the vapour volume against the cavitation coefficient we determine the cavitation sensitivity of the pump for each operating point.

A Study on the Heat Storage Characteristics of a Latent Heat Storage Tank with Shell and Tube Type (셀-튜브형 잠열축열조의 축열특성에 관한 연구)

  • 권영만;김경우;모정하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.745-754
    • /
    • 2000
  • An experimental study has been carried out in order to investigate the heat storage characteristics for a latent heat storage tank with horizontal shell and tube type. The heat storage tank consists of cylindrical capsules with a staggered tube bank. The effects of flow rates and initial temperature differences on the melting time and heat storage rates are examined. It is found that the melting time decreases with increase of the flow rates and initial temperature differences. Results also show that the time-averaged overall heat transfer coefficients increase in proportion to the increase of flow rates and initial temperature differences.

  • PDF

Heat Storage in a packed Bed (충전층내에서 축열에 따른 열전달)

  • Choi, Kyung-Jin;Ro, Sung-Tack
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 1978
  • An experiment has been performed of find a temperature distribution of the circulating fluid in a packed bed thermal storage system when the inlet fluid temperature is constant. The thermal storage system is a specific-heat type in which the circulating fluid, hot air, exchanges heat directly with the heat storage materials, glass balls, in a heat storage bin. An empirical equation which includes two dimensionless variables $t^*\;and\;T_f^*$, is obtained. Also, heat storage efficiency and heat storage capacity are calculated from this equation, The heat transfer coefficient calculated by the suggested equation was compared with the value determined by the existing empirical equation.

  • PDF

Estimation of irrigation supply from agricultural reservoirs based on reservoir storage data

  • Kang, Hansol;An, Hyunuk;Lee, Kwangya
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.4
    • /
    • pp.999-1006
    • /
    • 2019
  • Recently, the quantitative management of agricultural water supply, which is the main source for water consumption in Korea, has become more important due to the effective water management organization of the Korean government. In this study, the estimation method for irrigation supply based on agricultural reservoir storage data was improved compared to previous research, in which drought year selection was unclear, and the outlier data for the rainfall-irrigation supply were not eliminated in the regression analysis. In this study, the drought year was selected by the ratio of annual precipitation to mean annual precipitation and the storage rate observed before the start of irrigation. The outlier data for the rainfall-irrigation supply were eliminated by the Grubbs & Beck test. The proposed method was applied to nine agricultural reservoirs for validation. As a result, the ratio of annual precipitation to mean annual precipitation is less than 53% and the storage rate observed before the start of irrigation is less than 55% it was judged to be the drought year. In addition, the drought supply factor, K, was found to be 0.70 on average, showing closer results to the observed reservoir rates. This shows that water management at the real is appling drought year practice. It was shown that the performance of the proposed method was satisfactory with NSE (Nash-Sutcliffe model efficiency coefficient) and R2 (coefficient of determiniation) except for a few cases.

An Observation on the Viability and pH of Lactobacillus casei isolated from Yakult. (유산균음과에서 분리한 Lactobacillus casei의 저장온도별 균수 및 pH의 경시적 변화 관찰)

  • 이용욱;이원창
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.1-3
    • /
    • 1976
  • The authors studied the viability and pH of Lactobacillus casei which was isolated from the Yakult in terms of its storage temperature time(days). The following results have been obtained: (1) The viability test to Lactobacillus casei under storage in 4$\circ$C temperature condition in 35 days, has shown that the original population of $4.0\times 10^8$ organisms was decreased to $0.1\times 10^8$, under storage in 10$\circ$C temperature the organisms to $0.08\times 10^8$, in room temperature the organisms to $0.009\times 10^8$, and in 35$\circ$C temperature the organisms to $0.0009\times 10^8$. The correlation coefficient of storage period (days) and number of bacterial viability were significant as r=0.956(p<0.01) in 4$\circ$C, r=-0.999 (p<0.01) in 100C, r=0.975(p<0.01) in room temperature and r=-0.923(p<0.01) in 35$\circ$C. (2) The pH test to Lactobacillus casei unde.r storage in 4$\circ$C temperature condition for 35 days has shown that the original pH of 3.54 were acidified to 3.35, under storage in 10$\circ$C temperature the pH were acidified to 3.20, in room temperature the pH were acidified to 3.15, and in 35$\circ$C temperature the pH were acidified to 3.0. The correlation coefficient of variation of pH between storage period (days) and temperature were significant as r=-0.972(p<0.01) in 4$\circ$C, r=-0.922 (p<0.01) in 10$\circ$C, r=-0.963 (p<0.01) in room temperature and r=-0.953 in 35$\circ$C.

  • PDF

Stability Analysis of the CNG Storage Cavern in Accordance with Design Parameters (설계변수에 따른 압축천연가스 저장 공동의 거동 분석)

  • Park, Yeon-Jun;Moon, Hyung-Suk;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.192-202
    • /
    • 2013
  • The domestic demand of natural gas has increased continuously due to the sudden rise of oil price and regulations on greenhouse gas to global warming. In order to improve the supply security of natural gas market in Korea, the agreement on supply of pipeline natural gas (PNG) in Russia was signed between Gazprom and Korea Gas Corporation in 2008. If the supply plan of Russian natural gas is realized, underground storage facilities would be required in order to balance supply and demand of natural gas because the gas demand is concentrated in the winter. This study investigated the safety of the storage facility in quantitative way considering several design parameters such as gas pressure, depth of the storage cavern, rock condition and in-situ horizontal stress ratio. Two dimensional stress analyses were conducted using axi- symmetry condition to examine the behavior of cavern depending upon suggested design parameters. Results showed that the factor of safety, defined as the ratio of 'shear strength'/'shear stress', was largely affected by the depth, rock class and gas pressure but was insensitive to the coefficient of lateral pressure(Ko).

Heating Characteristics of Ondol using Heat Pump-Latent Heat Storage System (열펌프-잠열축열시스템을 이용한 온돌의 난방특성)

  • Kim, M.H.;Song, H.K.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • In these days the hot water circulating Ondol using the fossil fuel boiler is the heating system for the most of the Korean residents. Then it is installed without the heat storage medium in the Ondol heating layer, but the Korean traditional Ondol had been composed with the heat storage medium. The Ondol room without heat storage medium could not be comfortable because the room air temperature is not only changed unstably but also it has a defect too much fuel consumption. Therefore in this study the heat pump-latent heat storage Ondol as the new type of Ondol system was developed to solve these problems mentioned above, and the COP of the heat pump (Coefficient Of Performance), the latent heat storage characteristics in the new type of Ondol system and the temperature variation in the Ondol room with the ambient temperature were analyzed.

  • PDF

A Study on the Gap Test for Safe Storage of Explosives (안전한 화약류 저장을 위한 순폭 실험 연구)

  • Kim, Jun-Ha;Jung, Seung-Won;Kim, Jung-Gyu
    • Explosives and Blasting
    • /
    • v.40 no.3
    • /
    • pp.33-43
    • /
    • 2022
  • In order to minimize the impact on the structure during an internal explosion, the explosives storage must be kept at a distance from the inner wall to prevent the sympathetic detonation of the others explosives in an unexpected explosion. For safe explosives storage, a gap test was conducted by simulating the split arrangement of explosives inside the storage. In this study, the separation distance and arrangement between the emulsion explosives were applied differently to be sympathetic detonation at 2D of diameter and non-detonated at 2.5D. Considering the coefficient of detonation transmission and the size of the explosives storage, the explosive amount of 3kg was set, and most of the gap tests according to various arrangement changes were non-detonated, and safety was confirmed when applying the batch.