• Title/Summary/Keyword: stimulus-duration

Search Result 76, Processing Time 0.028 seconds

Changes of membrane resistance and membrane potentials by hyperpolarizing current stimulation in mouse unfertilized eggs (과분극 자극에 대한 mouse 미수정란의 세포막저항과 세포막전압의 변화)

  • Hong, Seong-geun;Kim, Ik-hyen;Cho, Young-deok
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 1991
  • For the observations of both the membrane properties and the excitability on the unfertilized eggs of female mice, changes of the membrane resistance and the membrane potential by hyerpolarizing current stimulation were recorded. As current-voltage relation was linear over the entire range (-180mV~+60mV), membrane resistance($R_m$) was calculated from the amplitude of electrotonic potential to a given stimulus current. Also the presence of anode-break excitation was confirmed. The results were as follows; 1. There was a linear relation between the membrane resistance and resting membrane potential, the expected input resistance was 61. 4M$\Omega$(resting membrane potential was $-18.9{\pm}8.7mV$, mean${\pm}$SD, n=30). 2. Transient depolarization with overshoot was generated just after hyperpolarizing current stimulus and showed the dependency of stimulus duration. 3. Transient depolarization lasted over 30ms, amplitude of these depolarization was increased by high $Ca^{{+}{+}}$(20mM) and inhibited by $Ca^{{+}{+}}$-antagonist, $Mn^{{+}{+}}$. 4. From the above results, it was suggested that the unfertilized mouse egg showed the characteristics of the excitable cell.

  • PDF

Lexical Status and the Degree of /l/-darkening

  • Ahn, Miyeon
    • Phonetics and Speech Sciences
    • /
    • v.7 no.3
    • /
    • pp.73-78
    • /
    • 2015
  • This study explores the degree of velarization of English word-final /l/ (i.e., /l/-darkness) according to the lexical status. Lexical status is defined as whether a speech stimulus is considered as a word or a non-word. We examined the temporal and spectral properties of word-final /l/ in terms of the duration and the frequency difference of F2-F1 values by varying the immediate pre-liquid vowels. The result showed that both temporal and spectral properties were contrastive across all vowel contexts in the way of real words having shorter [l] duration and low F2-F1 values, compared to non-words. That is, /l/ is more heavily velarized in words than in non-words, which suggests that lexical status whether language users encode the speech signal as a word or not is deeply involved in their speech production.

Study for Variational Characteristics of Brain According to Human Emotion -Human Emotion by Auditory Perception- (감성에 따른 뇌의 변화 특성에 대한 연구 -청각감각에 의한 감성-)

  • Whang, Min-Cheol;Sohn, Jin-Hun;Kim, Chul-Jung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.3
    • /
    • pp.609-619
    • /
    • 1997
  • The concept of human emotion is recently demanded to be imbedded in industrial product and environment for enhancing quality of life. Human emotion is attempted to be qualified and quantified by physiological measurements. EEG variation, one of the physiological measurement, is observed to characterize psychological response in this study. This study is to find function and process of brain according to emotion. Twenty university students participated in this study and experienced positive and negative emotion by auditory stimulus. Delta, theta, alpha and beta waves showed characteristic variation in normalized sense according to positive and negative emotion. Local area showing significant difference between positive and negative emotion decreases with stimulus duration. Delta, theta and beta waves increase with negative emotion while alpha wave does with positive emotion.

  • PDF

Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking (시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성)

  • Choi, Jin-Kyung;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

Study on Relation of Effects of Electro-acupuncture with Sex, Age, and Weight in Rats (흰쥐의 성별, 체중 및 주령에 따른 족삼리(足三里) 전침자극의 면화가 소장수송능(小腸輸送能)에 미치는 영향)

  • Hwang, Tae-Joon;Yu, Yun-Cho;Oh, Inn-Kun;Oh, Eun-Ki;Kim, Myung-Dong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.3
    • /
    • pp.748-754
    • /
    • 2007
  • Electroacupuncture is the combined treatment of mechanical and electric stimuli on the needle head, on which electricity runs after acupuncturing at the acupuncture points. It is reported that its treatment effect depends on the parameter of stimulus, which is wave of stimulus, frequency, voltage, and duration of electric current. To get the effective treatment, stimulus intensity over threshold is needed. We planned to experiment whether acupuncture effect is affected by sex, age, and weight. After we conducted electric stimulus at Zusanli(ST 36) which is known to increase small intestinal motility in normal rats, we observed the effects and got the following results. Though the increased effects of small intestinal motility of electro-acupuncture at Zusanli(ST 36) did not show the difference of sex, this effect was observed to have a tendency to decrease according to weight increase without distinction of sex. But the effect of electro-acupuncture shown in 4, 5, 7 weeks old without distinction of sex was observed to have a tendency to decrease with the growing of weeks-old in the male rat group. And the significant change without specific tendency was observed in the 4, 5 weeks old female rat group. This result suggested that sex, weight, and age should be considered to get the efficient electro-acupuncture. The more experimental study should be advanced to investigate the correlation between the factors that can affect the acupuncture treatment, and, afterward, the interconnection into the clinical use.

The Effect of Retinal and Perceived Motion Trajectory of Visual Motion Stimulus on Estimated Speed of Motion (운동자극의 망막상 운동거리와 지각된 운동거리가 운동속도 추정에 미치는 영향)

  • Park Jong-Jin;Hyng-Chul O. Li;ShinWoo Kim
    • Korean Journal of Cognitive Science
    • /
    • v.34 no.3
    • /
    • pp.181-196
    • /
    • 2023
  • Size, velocity, and time equivalence are mechanisms that allow us to perceive objects in three-dimensional space consistently, despite errors on the two-dimensional retinal image. These mechanisms work on common cues, suggesting that the perception of motion distance, motion speed, and motion time may share common processing. This can lead to the hypothesis that, despite the spatial nature of visual stimuli distorting temporal perception, the perception of motion speed and the perception of motion duration will tend to oppose each other, as observed for objects moving in the environment. To test this hypothesis, the present study measured perceived speed using Müller-Lyer illusion stimulus to determine the relationship between the time-perception consequences of motion stimuli observed in previous studies and the speed perception measured in the present study. Experiment 1 manipulated the perceived motion trajectory while controlling for the retinal motion trajectory, and Experiment 2 manipulated the retinal motion trajectory while controlling for the perceived motion trajectory. The result is that the speed of the inward stimulus, which is perceived to be shorter, is estimated to be higher than that of the outward stimulus, which is perceived to be longer than the actual distance traveled. Taken together with previous time perception findings, namely that time perception is expanded for outward stimuli and contracted for inward stimuli, this suggests that when the perceived trajectory of a stimulus manipulated by the Müller-Lyer illusion is controlled for, perceived speed decreases with increasing duration and increases with decreasing duration when the perceived distance of the stimulus is constant. This relationship suggests that the relationship between time and speed perceived by spatial cues corresponds to the properties of objects moving in the environment, i.e, an increase in time decreases speed and a decrease in time increases speed when distance remains the same.

EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE (저출력 레이저조사가 동통반응에 미치는 영향)

  • Kim, Sung-Kyo;Yoon, Soo-Han;Lee, Jong-Heun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.

  • PDF

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF

Length-dependent Staircase Phenomenon and Calcium Inotropisn in Isolated Rabbit Papillary Muscle (적출 유두근에서 근육길이에 따른 계단현상 및 칼슘 수축력의 변화)

  • Kim, Ki-Whan;Earm, Yung-E;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.14 no.2
    • /
    • pp.7-16
    • /
    • 1980
  • The effects of various inotropic interventions on the shape of the steady state length tension relation and the length-dependent activation process in cardiac muscle were studied. The influence of inotropic interventions upon the action potential was also observed. The range of varying muscle length was from the optimal length$(l_{max})$, where the active tension production is maximal, to 0.85 $l_{max}$. Changes in stimulus frequency or in external bathing Ca concentration constituted the inotropic interventions in this experiment. The papillary muscles were isolated from the rabbit right ventricles and perfused with $HCO-_3\;-buffered$ normal Tyrode solution which was aerated with $3%\;CO_2-97%\;O_2$ mixed gas and kept at $35^{\circ}C$. Resting Passive tension at $l_{max}$ was approximately 30% of the total tension and appeared from the muscle length of 0.90 $l_{max}$. The effect of stimulus frequency on the steady state level of developed tension was: As the stimulus frequency was increased from 0.1 to 0.5 Hz, there was little change in developed tension. As the frequency was increased further, to a value of about 3 Hz, tension increased steeply. Further increase of the frequency to 5 Hz had little additional effect on the developed tension. The length-tension curves for isometric peak tension became more steeper with the degree of potentiation by inotropic interventions. The relative steepness of the normalized length-tension curves where tension production was expressed as a percentage of maximal tension developed at $l_{max}$, varied inversely with the level of inotropic state and these curves were not superimposable one another. Thus at the stimulus frequency of 2 Hz or at the external Ca concentration of 8 mM, the relative decline in the developed tension for a given change in muscle length was considerably less than the decline observed at the frequency of 0.5 Hz or at the concentration of 2 mM Ca. Action potential duration was prolonged significantly as the frequency increased from 0.2 to 2 Hz, and this change in action potential duration was not observable on the changes in muscle length. There was a tendency of the hyperpolarization of membrane potential when the muscle length was shortened from $l_{max}$ to 0.95 $l_{max}$. These results support the hypothesis that there is a length-dependence of the activation process.

  • PDF

Effects of Size Illusion According to Distance Information Restriction on Time Perception (거리 정보 제한에 따른 크기 착시가 시간 지각에 미치는 영향)

  • Kim, Min-Kyu;Lee, Won-Seob;Kim, Shin-Woo;Li, Hyung-Chul O.
    • Science of Emotion and Sensibility
    • /
    • v.25 no.1
    • /
    • pp.79-90
    • /
    • 2022
  • IThe perception of sub-second duration through the visual sensory system is affected by non-temporal characteristics (factors other than the duration of the stimulus). However, studies have shown that if distance information is abundant and size constancy maintained, the duration of the target is constantly perceived. The current study examined the relationship between size and time perception constancy in a three-dimensional environment with limited distance information. A device was constructed to limit the participants' bilateral and monocular cues. This prevented participants from maintaining size constancy, resulting in size illusions that could not accurately perceive physical size. In Experiment 1, the size of the physical stimulus of reference and test stimuli were the same at all viewing distances. The results suggest that, despite the same physical size, stimuli with close observations were perceived to be greater and lasted longer. In Experiment 2, the retinal size of the reference stimuli and test stimuli was controlled equally at all viewing distances. As a result, although the physical size of the stimuli increased as the observation increased, the perceived size of all the stimuli was the same. Therefore, the duration of the target was constantly perceived at all viewing distances. The results of this study demonstrate that even when distance information is limited, time perception is affected by the perceived size of the object. It also suggests that when rich distance information exists, the duration of the object can be constantly perceived even if the observation distance varies.